nVent P2KDL1686 ProLine G2 Disconnect Package Type 12 LH 1Dr, 1600x800x600, Lt Gray, Steel
UPC: 783510321185
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 12 gauge (2.5mm), roll-formed steel frame with welded steel corners and hybrid frame profile for superior performance under load
- Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
- Disconnect Frames >1000 mm include two removable center uprights (front and rear) which are offset 100 mm from the center of the frame
- Standard right- or left-hand provision will accept the following types of flange-mounted disconnect devices: Allen-Bradley (Bulletin 1494V - disconnect switches with flange-mounted, variable-depth operating mechanisms and Bulletin 1494V flange-mounted var
- Right-hand disconnects have the mullion on the right, and door(s) hinged on the left; left hand disconnects have the mullion on the left, and door(s) hinged on the right; mullion door is opened via two quarter-turn cams
- Two-door disconnect packages have a removable center upright in the front, and both doors swing in the same direction (not overlapping)
- A low-profile flush swing handle with key lock (other options available) operates an internal 3-point latch system on the door; Door bar system on all doors (not on disconnect mullion)
- Door bar system on all doors (not on disconnect mullion)
- Integrated mechanical interlock system from the door(s) to the disconnect mullion; Interlock must be defeated to unlock either door: the primary door must be in the open position to open the secondary door, and the primary door must be in the open positio
- Seamless polyurethane gasket provides a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant
Specifications
Application | Arc Flash Safety; Controls and Drives |
Color | Light Gray |
Color Code | RAL 7035 |
Current Rating | 508A |
Depth | 23.82 |
Depth | 605 |
Door Quantity | 1 |
Finish | Powder Coated |
Height | 63.07 |
Height | 1,602 |
IP Rating | IP55 |
Material | Steel |
Material | Mild Steel |
Max Rack Mount Unit | 33 |
Max Subpanel Size | 1506 x 728 mm |
Max Subpanel Size | 59.3 x 28.7 in |
Mounting Type | Floor Mount |
Nema Rating | Type 12 |
Product Family | ProLine |
Series | ProLine G2 |
Size | 1600x800x600 mm |
Thickness | 14 ga |
Thickness | 1.9 mm |
Type | Mild Steel Modular Industrial Disconnect Enclosures |
Weight | 190 lb |
Width | 31.8 |
Width | 808 |

LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, GreyFrequently Asked Questions
What are the key features of the ProLine G2 enclosure?
The ProLine G2 has a 15% higher load rating than competitors, can hold over 45% more weight on the subpanel, and offers more than 400 standard industrial packages. It features a comprehensive set of standard components for creating custom enclosure solutions.
What enclosure frame sizes are available?
Frame heights range from 600mm to 2200mm. Widths range from 400mm to 1200mm. Depths range from 400mm to 1000mm, with specific combinations available for each height.
What mounting options are available for internal components?
Options include full subpanels, partial subpanels, swing-out subpanels, side-mount subpanels, grid straps, 19-inch rack angles, and adjustable rack-mounting rails.
What type of environmental ratings are supported?
The ProLine G2 supports Type 12 and Type 3R ratings. Specific components like sealed plinth bases and gland plates help maintain environmental integrity.
What cable management solutions are offered?
Solutions include cable entry cabinets, top mounting modules, vertical tie-down cable managers, basket trays, power strip brackets, and various cable management accessories like D-rings and VELCRO cable wraps.
How to Install the P2KDL1686 PROLINE G2
Installation guide for mounting the P2KDL1686 PROLINE G2 enclosure.
Estimated time: 1h
Tools needed:
Measuring tape, Level, Drill, Screwdriver set, Pliers, Wire cutters, Wire strippers
Supplies needed:
Mounting hardware (screws, anchors), Wire connectors, Grounding lug, Grounding wire
- Plan the Mounting Location
Select a suitable location for the enclosure. Ensure there is adequate space for installation and future access. Check the enclosure's dimensions against the available space. Refer to the datasheet for specific clearance requirements.
- Prepare the Mounting Surface
Mark the mounting hole locations on the wall or mounting surface using the enclosure's mounting template or by measuring. Ensure the marks are level. Drill pilot holes as needed, considering the type of wall material and the required mounting hardware.
- Mount the Enclosure
Securely attach the enclosure to the mounting surface using appropriate mounting hardware. Ensure the enclosure is level and firmly fixed. Verify that the mounting is robust enough to support the weight of the enclosure and its contents.
- Install Grounding
Connect the grounding wire to the designated grounding lug inside the enclosure and to the building's grounding system. Ensure a secure and reliable ground connection. Refer to local electrical codes for proper grounding procedures.
- Prepare for Internal Components
Remove any internal mounting panels or components as necessary to facilitate wiring. Plan the layout of internal equipment, considering cable routing and accessibility.
- Wire Internal Components
Install and wire any internal components according to their respective documentation. Use appropriate wire sizes and connectors. Ensure all connections are secure and properly insulated. Follow all applicable electrical codes and safety standards.
- Close and Secure the Enclosure
Once all internal wiring and component installation is complete, close the enclosure door and secure it with the provided latches or locks. Ensure the door seals properly to protect the internal components from the environment.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.