Authorized nVent Distributor
nVent P2KDL1686 - ProLine G2 Disconnect Package Type 12 LH 1Dr, 1600x800x600, Lt Gray, Steel

nVent P2KDL1686 ProLine G2 Disconnect Package Type 12 LH 1Dr, 1600x800x600, Lt Gray, Steel

UPC: 783510321185


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent ProLine G2 Disconnect Package (SKU: P2KDL1686) delivers a complete, ready-to-install Type 12 industrial enclosure solution designed for flange-mount disconnect switches and circuit breakers. Engineered for durability and compliance, this 1600x800x600 mm enclosure combines a 12-gauge roll-formed steel frame with fully welded corners and hybrid profile for superior strength and structural integrity. The left-hand (LH) configuration features a hinged disconnect mullion with a standard cutout, enabling seamless integration of major-brand disconnect devices while providing unobstructed interior access. The internal 3-point latch system, operated by a flush swing handle with defeater, ensures secure closure and interlocking from the primary door to the mullion for enhanced safety and tamper resistance. Side covers are included, streamlining installation and reducing on-site assembly time. This package is 508A Listed, NEMA/EEMAC Type 12, and CSA File Number 42186 certified, meeting stringent electrical safety standards for industrial environments. The IP55 rating (IEC 60529) provides robust protection against dust ingress and water jets, making it ideal for harsh manufacturing, automation, and processing facilities. Professionals select ProLine G2 Disconnect Packages for their modularity, ease of customization, and compatibility with industry-standard disconnect hardware. The Full Mounting Subpanel maximizes space utilization, while removable center uprights (for frames over 1000 mm) offer flexibility for cable management and device mounting. Trusted by engineers and facility managers, nVent’s ProLine G2 series is backed by decades of innovation in electrical protection and enclosure solutions, ensuring reliable performance in critical applications such as motor control centers, HVAC systems, and industrial machinery. Installation is simplified with pre-drilled rectangular and round holes accommodating 25-mm DIN standards, reducing fabrication time. The light gray finish provides a professional appearance while resisting corrosion, and the package’s design supports compliance with OSHA and NEC regulations for worker safety. Whether upgrading legacy systems or deploying new infrastructure, the ProLine G2 Disconnect Package delivers a cost-effective, code-compliant solution that accelerates project timelines without compromising quality or safety.
  • 12 gauge (2.5mm), roll-formed steel frame with welded steel corners and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Disconnect Frames >1000 mm include two removable center uprights (front and rear) which are offset 100 mm from the center of the frame
  • Standard right- or left-hand provision will accept the following types of flange-mounted disconnect devices: Allen-Bradley (Bulletin 1494V - disconnect switches with flange-mounted, variable-depth operating mechanisms and Bulletin 1494V flange-mounted var
  • Right-hand disconnects have the mullion on the right, and door(s) hinged on the left; left hand disconnects have the mullion on the left, and door(s) hinged on the right; mullion door is opened via two quarter-turn cams
  • Two-door disconnect packages have a removable center upright in the front, and both doors swing in the same direction (not overlapping)
  • A low-profile flush swing handle with key lock (other options available) operates an internal 3-point latch system on the door; Door bar system on all doors (not on disconnect mullion)
  • Door bar system on all doors (not on disconnect mullion)
  • Integrated mechanical interlock system from the door(s) to the disconnect mullion; Interlock must be defeated to unlock either door: the primary door must be in the open position to open the secondary door, and the primary door must be in the open positio
  • Seamless polyurethane gasket provides a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant

Specifications

Application
Arc Flash Safety; Controls and Drives
Color
Light Gray
Color Code
RAL 7035
Current Rating
508A
Depth
23.82
Depth
605
Door Quantity
1
Finish
Powder Coated
Height
63.07
Height
1,602
IP Rating
IP55
Material
Steel
Material
Mild Steel
Max Rack Mount Unit
33
Max Subpanel Size
1506 x 728 mm
Max Subpanel Size
59.3 x 28.7 in
Mounting Type
Floor Mount
Nema Rating
Type 12
Product Family
ProLine
Series
ProLine G2
Size
1600x800x600 mm
Thickness
14 ga
Thickness
1.9 mm
Type
Mild Steel Modular Industrial Disconnect Enclosures
Weight
190 lb
Width
31.8
Width
808
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

Frequently Asked Questions

What are the key features of the ProLine G2 enclosure?

The ProLine G2 has a 15% higher load rating than competitors, can hold over 45% more weight on the subpanel, and offers more than 400 standard industrial packages. It features a comprehensive set of standard components for creating custom enclosure solutions.

What enclosure frame sizes are available?

Frame heights range from 600mm to 2200mm. Widths range from 400mm to 1200mm. Depths range from 400mm to 1000mm, with specific combinations available for each height.

What mounting options are available for internal components?

Options include full subpanels, partial subpanels, swing-out subpanels, side-mount subpanels, grid straps, 19-inch rack angles, and adjustable rack-mounting rails.

What type of environmental ratings are supported?

The ProLine G2 supports Type 12 and Type 3R ratings. Specific components like sealed plinth bases and gland plates help maintain environmental integrity.

What cable management solutions are offered?

Solutions include cable entry cabinets, top mounting modules, vertical tie-down cable managers, basket trays, power strip brackets, and various cable management accessories like D-rings and VELCRO cable wraps.

How to Install the P2KDL1686 PROLINE G2

Installation guide for mounting the P2KDL1686 PROLINE G2 enclosure.

Estimated time: 1h

Tools needed:

Measuring tape, Level, Drill, Screwdriver set, Pliers, Wire cutters, Wire strippers

Supplies needed:

Mounting hardware (screws, anchors), Wire connectors, Grounding lug, Grounding wire

  1. Plan the Mounting Location

    Select a suitable location for the enclosure. Ensure there is adequate space for installation and future access. Check the enclosure's dimensions against the available space. Refer to the datasheet for specific clearance requirements.

  2. Prepare the Mounting Surface

    Mark the mounting hole locations on the wall or mounting surface using the enclosure's mounting template or by measuring. Ensure the marks are level. Drill pilot holes as needed, considering the type of wall material and the required mounting hardware.

  3. Mount the Enclosure

    Securely attach the enclosure to the mounting surface using appropriate mounting hardware. Ensure the enclosure is level and firmly fixed. Verify that the mounting is robust enough to support the weight of the enclosure and its contents.

  4. Install Grounding

    Connect the grounding wire to the designated grounding lug inside the enclosure and to the building's grounding system. Ensure a secure and reliable ground connection. Refer to local electrical codes for proper grounding procedures.

  5. Prepare for Internal Components

    Remove any internal mounting panels or components as necessary to facilitate wiring. Plan the layout of internal equipment, considering cable routing and accessibility.

  6. Wire Internal Components

    Install and wire any internal components according to their respective documentation. Use appropriate wire sizes and connectors. Ensure all connections are secure and properly insulated. Follow all applicable electrical codes and safety standards.

  7. Close and Secure the Enclosure

    Once all internal wiring and component installation is complete, close the enclosure door and secure it with the provided latches or locks. Ensure the door seals properly to protect the internal components from the environment.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.