nVent P2KOD16164 - ProLine G2 Industrial Packages Type 12 2Dr, 1600x1600x400, Lt Gray, Steel
nVent

P2KOD16164

UPC: 783510322267


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Overview

Introducing the **nVent ProLine G2 Industrial Package Type 12 (SKU: P2KOD16164)**, a robust, ready-to-install enclosure solution engineered for demanding industrial environments. Designed by nVent—an industry leader in thermal management and electrical protection—the ProLine G2 combines durability, convenience, and compliance in a single, pre-configured package. This **1600x1600x400mm (2-door, right-hand swing)** enclosure is constructed from **light gray steel**, offering superior corrosion resistance and structural integrity for long-term performance in harsh conditions. The ProLine G2 is a **full-featured Type 12 enclosure**, meeting NEMA 12/IP54 standards for protection against dust, dripping water, and non-corrosive liquids. Unlike traditional enclosures that require separate ordering of components, this package includes a **pre-assembled frame, solid door(s) with handle and key lock, solid top and rear cover, full mounting subpanel, gland plate, and four lifting eyes**—eliminating guesswork and streamlining procurement. Side covers are available separately to support **baying or joining applications**, providing flexibility for system expansion. **Key Applications & Industries:** The ProLine G2 is ideal for **industrial automation, manufacturing, food and beverage processing, pharmaceuticals, and data centers**, where reliable electrical and electronic component housing is critical. Common uses include: - **Control panels** for motor starters, PLCs, and variable frequency drives (VFDs) - **Power distribution centers** in harsh or washdown environments - **Networking and telecom enclosures** requiring NEMA 12/IP54 protection - **Machine automation systems** where dust and moisture resistance are mandatory **Why Choose nVent ProLine G2?** nVent’s reputation for innovation and reliability makes the ProLine G2 a trusted choice among engineers and facility managers. The **pre-drilled mounting subpanel** simplifies internal component installation, while the **gland plate** ensures secure cable entry without compromising protection. The **light gray powder-coated finish** resists chipping and fading, maintaining a professional appearance even in high-traffic areas. **Installation & Compliance Considerations:** Designed for **ease of installation**, the ProLine G2 features **integrated lifting eyes** for safe handling and a **solid rear cover** for added security. The **Type 12 rating** ensures compliance with OSHA, NEC, and IEC standards, making it suitable for both indoor and protected outdoor applications (when properly installed). For applications requiring additional ventilation or heat dissipation, nVent offers compatible accessories like **filter fans, louvers, and thermostats**—though this specific model prioritizes **dust and drip resistance** over airflow. **Durability & Maintenance:** Constructed from **high-grade steel with a durable powder coat**, the ProLine G2 withstands impacts, vibrations, and temperature fluctuations. The **key-lockable door** provides tamper resistance, while the **removable rear cover** allows for quick access during maintenance or upgrades. For washdown environments, the enclosure’s smooth surfaces and sealed seams minimize contamination risks. **Industry-Leading Support & Warranty:** Backed by nVent’s **global engineering expertise** and **comprehensive warranty**, the ProLine G2 delivers peace of mind for mission-critical applications. Whether you’re retrofitting an existing system or designing a new facility, this enclosure package reduces lead times and eliminates the complexity of sourcing individual components. For professionals seeking a **high-performance, code-compliant, and hassle-free enclosure solution**, the nVent ProLine G2 Industrial Package (P2KOD16164) is the smart choice—combining **premium construction, regulatory compliance, and nVent’s trusted reliability** in a single, ready-to-deploy package.
  • 12-gauge (2.5 mm) roll-formed steel with welded corners, and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Enclosures with a width of 1200mm or less have a single-piece rear cover, and can accommodate a fully-recessed mounting subpanel; enclosures with a width of greater than 1200mm have two rear covers that affix to a removable center upright/vertical combina
  • Gasket is seamless polyurethane providing a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant
  • Door bar system present on all doors (including window doors)
  • Single/primary door includes Smooth Glide Latching System, 3-point roller latch system with timed latch engagement, for enclosures greater than or equal to 1000 mm in height; system ensures a solid and repeatable seal with a low closure force
  • 2-door enclosures include overlapping double doors to provide full-width open front, with a secondary door that latches with two levers
  • Reversible hinging on single doors (default left hinge), and on overlapping double doors (default right door primary door)
  • Two grounding studs present on each door
  • Low-Profile Flush Swing Handle with key lock on standard versions; double bit lock on 'E' versions; other handle options available (sold separately)

Specifications

Application
Controls and Drives; Power Distribution
Color
Light Gray
Color
Lt Gray
Color Code
RAL 7035
Depth
15.94
Depth
405
Door Quantity
2
Finish
Powder Coated
Height
63.07
Height
1,602
Material
Mild Steel
Material
Steel
Max Rack Mount Unit
33
Max Subpanel Size
1506 x 1528 mm
Max Subpanel Size
59.3 x 60.2 in
Nema Rating
Type 12
Product Family
ProLine
Series
ProLine G2 Industrial Packages
Size
1600x1600x400
Type
Mild Steel Modular Industrial Enclosures
Weight
404 lb
Width
63.29
Width
1,608
Package Dimensions (L x W x H)
50 IN x 30.5 IN x 70 IN
Package Dimensions (L x W x H)
127 cm x 77.47 cm x 177.8 cm
Package Weight (Imperial)
404.000 L
Package Weight (Metric)
183.254 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

What are the key features of the ProLine G2 enclosure?

The ProLine G2 has a 15% higher load rating than competitors, can hold over 45% more weight on subpanels, and offers more than 400 standard industrial packages. It features a welded steel frame with rectangular and round hole patterns compatible with 25 mm DIN standard.

What environmental ratings are available for ProLine G2?

ProLine G2 offers Type 3R and Type 12 ratings. EMC options are also available for various components like frames, covers, doors, and tops.

What mounting options are available for internal components?

ProLine G2 offers multiple mounting solutions including full subpanels, partial subpanels, swing-out subpanels, side-mount subpanels, grid straps, 19-inch rack angles, and adjustable rack-mounting rails.

What safety features are included in the ProLine G2?

Safety features include mechanical and electrical interlocks, barrier panels, Sequestr external disconnect package to mitigate arc flash, and anti-tip brackets to prevent enclosure tipping.

What cable management solutions does ProLine G2 provide?

Cable management options include cable entry cabinets, top mounting modules, vertical tie-down cable managers, basket trays, power strip brackets, D-ring cable managers, and VELCRO cable wraps.

How to Install the P2ACU16 Controller

This guide provides step-by-step instructions for installing and configuring the P2ACU16 Controller for optimal performance.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the P2ACU16 controller to a suitable mounting surface using the provided mounting screws. Ensure it is level and securely fastened.

  2. Connect power supply

    Using wire connectors, connect the power supply wires to the designated terminals on the P2ACU16. Ensure the connections are tight and insulated to prevent short circuits.

  3. Wire the input/output terminals

    Connect the input and output devices to the corresponding terminals on the P2ACU16. Refer to the wiring diagram for correct terminal assignments.

  4. Configure the controller settings

    Power on the P2ACU16 and access the configuration menu using the front panel buttons. Set the desired parameters according to your application requirements.

  5. Calibrate the controller

    Perform a calibration of the P2ACU16 by following the on-screen instructions. Ensure all sensors and inputs are functioning correctly.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.