nVent MCD18124R5 - Modular Double Door, with Plate, Rear Panel, 1800x1200x400mm, Gray, Mild Steel
nVent

MCD18124R5

UPC: 783510490645


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent MCD Modular Double Door Enclosure (SKU: MCD18124R5) is a robust, floor-standing solution engineered for demanding industrial environments. This combinable enclosure system is specifically designed to address space constraints, offering a practical alternative to single-door units where a wide door swing would impede workflow or access. By dividing the opening into two doors, the MCD significantly reduces the required clearance in front of the enclosure, making it an ideal choice for tight installation spaces. This design also distributes the weight load, enhancing the overall structural integrity and ease of operation. Constructed from durable mild steel and finished in a standard industrial gray, the MCD enclosure provides excellent protection for sensitive electrical and electronic components. Its IP 55 protection degree ensures that internal equipment is safeguarded against dust ingress and low-pressure water jets, making it suitable for a wide array of applications across various sectors. Whether used for control systems, power distribution, automation equipment, or telecommunications hardware, the MCD enclosure offers a reliable housing solution. Key features and benefits include: * **Space-Saving Double Door Design:** Minimizes front clearance requirements, crucial for confined installations. * **Enhanced Load Capacity:** Dual doors distribute weight, improving handling and structural stability. * **IP 55 Protection:** Offers superior defense against environmental contaminants and water ingress. * **Modular Combinability:** Allows for flexible configuration and expansion to meet evolving project needs. * **Durable Mild Steel Construction:** Ensures longevity and resistance to industrial wear and tear. * **Integrated Mounting Plate and Rear Panel:** Facilitates efficient component mounting and internal organization. The nVent MCD range is a testament to nVent's commitment to providing high-quality, reliable enclosure solutions. Professionals rely on nVent for their expertise in protecting critical infrastructure, and the MCD series exemplifies this dedication. The thoughtful design, including the inclusion of a mounting plate and rear panel, streamlines the installation process, allowing for quicker deployment and reduced labor costs. This enclosure is a strategic investment for any facility prioritizing operational efficiency, component protection, and long-term system reliability. Its versatility allows it to be integrated into diverse industrial settings, from manufacturing plants and processing facilities to utility substations and data centers.
  • Material: Frame: 1.5 mm painted steel. Doors: 2 mm painted steel. Rear, roof and side panels: 1.5 mm painted steel. Mounting plate: 3 mm galvanized steel. Bottom plates: 1 mm galvanized steel.
  • Frame: Seam welded reversed open profiles with 25 mm hole pattern, according to DIN 43660. Including integrated external hole pattern.
  • Doors: Mounted with four hinges. Including door frame with 25 mm hole pattern. Doors cannot be reversed. Separate doors to be ordered for left hand door locking.
  • Rear panel: Fitted by M6 torx screws. Standard facilities for rear doors mounting. Split rear panels in 1600 mm wide enclosures. RD version comes with rear door instead of rear panel.
  • Side panels: Supplied as an accessory.
  • Roof panel: Removable.
  • Lock: Espagnolette 4-point locking system in the main door and 2-point locking system in the slave door. Standard double-bit lock with 3 mm insert. Standard inserts, cylinders, lift handles and T-handles are available as accessories.
  • Bottom plates: Consists of three or four (D>600) pieces.
  • Mounting plate: Double folded and slides into position. Adjustable in depth by steps of 25 mm, with the MPD02 accessory. Supplied, attached on the outside of the enclosure packaging.
  • Earthing: All panels are earthed through their fittings and equipped with a separate earthing stud.

Specifications

Application
Controls and Drives;Factory Automation and Process Control
Body Thickness
16 ga
Body Thickness
1.5 mm
Cable Entry
No
Color
Light Gray
Color
Gray
Color
Grey
Color Code
RAL 7035
Construction
Body: 16 gauge Door: 14 gauge
Depth
400 mm
Depth
15.75
Depth
400
Door Thickness
14 ga
Finish
Powder Coated
Finish
Powder Coating
Height
1,800 mm
Height
70.87
Height
1,800
IP Rating
IP55
Material
Mild Steel
Max Mounting Depth
14.13 in
Max Mounting Depth
11.1 in
Mounting
Free Standing
Mounting Plate Height
1,694;66.7 mm;mm
Mounting Plate Included
Yes
Mounting Plate Width
43.07 in
Mounting Type
Floor-standing
NEMA Rating
NEMA Type 12
NEMA Rating
12
Protection Rating
NEMA Type 12
Rear Door Included
No
Rear Panel Included
Yes
Series
MCD
Size
1800x1200x400mm
Size
70.87 x 47.24 x 15.75 inch
Type
Mild Steel Modular Industrial Enclosures
Weight
423.6 lb
Width
1,200 mm
Width
47.24
Width
1,200
Package Dimensions (L x W x H)
71.24 IN x 47.62 IN x 47.87 IN
Package Dimensions (L x W x H)
180.9496 cm x 120.9548 cm x 121.5898 cm
Package Weight (Imperial)
423.600 L
Package Weight (Metric)
192.145 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the MCS20085R5 Controller

This guide provides step-by-step instructions for installing and configuring the MCS20085R5 Controller, ensuring proper mounting, wiring, and initial setup.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors, Floor plate (if required)

  1. Mount the controller

    Secure the MCS20085R5 Controller to the designated mounting surface using the provided mounting screws. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Use wire connectors to connect the power and signal wires to the appropriate terminals on the controller. Ensure all connections are secure and insulated.

  3. Verify the installation

    Use a multimeter to check the voltage at the controller terminals to ensure proper power supply. Confirm that all connections are correct and secure.

  4. Configure the controller settings

    Access the controller's configuration interface and input the necessary parameters for operation. Follow the manufacturer's guidelines for specific settings.

  5. Calibrate the controller

    Perform any required calibration procedures as outlined in the user manual to ensure optimal performance of the MCS20085R5 Controller.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.