Authorized nVent Distributor
nVent P2KOD16165E - ProLine G2 Industrial Packages Type 12 E-Cnfg 2Dr, 1600x1600x500, Lt Gray, Steel

nVent P2KOD16165E ProLine G2 Industrial Packages Type 12 E-Cnfg 2Dr, 1600x1600x500, Lt Gray, Steel

UPC: 783510322274


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The **nVent ProLine G2 Industrial Package (SKU: P2KOD16165E)** is a pre-engineered, Type 12-rated enclosure designed to streamline industrial electrical and automation installations. Manufactured by nVent, a global leader in thermal management and electrical solutions, this ready-to-use package eliminates the complexity of sourcing individual components by bundling a robust steel frame, solid door with handle and key lock, solid top and rear cover, full mounting subpanel, gland plate, and four lifting eyes into a single part number. Side covers are available separately to support baying or joining applications, ensuring scalability for expanding systems. With a compact 1600x1600x500mm footprint and light gray finish, this enclosure is engineered for durability, ease of installation, and long-term performance in demanding environments. **Key Features and Benefits** The ProLine G2 Industrial Package is built for professionals who demand reliability without compromise. The **Type 12 rating** ensures protection against dust, falling dirt, and non-corrosive liquids, making it ideal for manufacturing plants, food processing facilities, and industrial automation hubs where environmental contaminants pose a risk. The **solid door with key lock** provides secure access control, while the **full mounting subpanel** simplifies internal component organization, reducing wiring time and improving system maintainability. The **gland plate** accommodates cable entry points efficiently, and the **four lifting eyes** enable safe, ergonomic handling during installation or relocation. **Typical Applications Across Industries** This enclosure is a versatile solution for a wide range of industrial applications. In **manufacturing**, it houses PLCs, HMIs, and motor controllers, protecting sensitive electronics from harsh conditions. **Food and beverage processors** rely on Type 12 enclosures to meet hygiene standards while safeguarding against washdowns and particulate contamination. **Automation integrators** use ProLine G2 packages to consolidate control panels for robotic systems, CNC machines, and conveyor networks, ensuring centralized management and reduced footprint. The **light gray powder-coated steel** finish resists corrosion and blends seamlessly into industrial settings, while the modular design allows for future expansions or reconfigurations as operational needs evolve. **Why Choose nVent ProLine G2?** nVent is a trusted name in industrial electrical solutions, known for innovation and durability. The ProLine G2 series reflects this legacy, offering **pre-configured convenience** that saves procurement time and reduces the risk of component mismatches. Unlike generic enclosures, this package is engineered with **industry-specific certifications** (Type 12, IP54 equivalent) and **rigorous testing** to withstand temperature fluctuations, vibrations, and mechanical stress. Professionals in **oil and gas, pharmaceuticals, and water treatment** sectors choose nVent for its compliance with stringent safety standards and its ability to simplify complex installations. **Installation and Integration Considerations** The ProLine G2 Industrial Package is designed for **quick deployment** with pre-drilled mounting holes and a modular layout that accommodates standard DIN rails, backplanes, or custom mounting solutions. The **solid top and rear cover** ensure electromagnetic interference (EMI) containment, while the optional side covers (ordered separately) enable seamless baying for larger control systems. For optimal performance, install the enclosure in a **well-ventilated area** away from direct sunlight or extreme heat sources, and use the included lifting eyes to position it safely. nVent provides comprehensive documentation, including CAD models and installation guides, to support engineers and technicians throughout the project lifecycle. **Industry-Leading Support and Compliance** Backed by nVent’s global service network, the ProLine G2 package includes access to technical support, replacement parts, and compliance documentation (e.g., UL, CE, RoHS). Whether you’re retrofitting an existing facility or designing a new smart factory, this enclosure delivers the **performance, scalability, and peace of mind** required for mission-critical applications. Trust nVent to provide a solution that not only meets your specifications but exceeds them with uncompromising quality.
  • 12-gauge (2.5 mm) roll-formed steel with welded corners, and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Enclosures with a width of 1200mm or less have a single-piece rear cover, and can accommodate a fully-recessed mounting subpanel; enclosures with a width of greater than 1200mm have two rear covers that affix to a removable center upright/vertical combina
  • Gasket is seamless polyurethane providing a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant
  • Door bar system present on all doors (including window doors)
  • Single/primary door includes Smooth Glide Latching System, 3-point roller latch system with timed latch engagement, for enclosures greater than or equal to 1000 mm in height; system ensures a solid and repeatable seal with a low closure force
  • 2-door enclosures include overlapping double doors to provide full-width open front, with a secondary door that latches with two levers
  • Reversible hinging on single doors (default left hinge), and on overlapping double doors (default right door primary door)
  • Two grounding studs present on each door
  • Low-Profile Flush Swing Handle with key lock on standard versions; double bit lock on 'E' versions; other handle options available (sold separately)

Specifications

Application
Controls and Drives; Power Distribution
Color
Light Gray
Color Code
RAL 7035
Depth
405 mm
Depth
19.68 in
Depth
405
Door Quantity
2-2
Door Quantity
2
Finish
Powder Coated
Height
1,602 mm
Height
63.07 in
Height
1,602
Material
Steel
Material
Mild Steel
Max Rack Mount Unit
33
Max Subpanel Size
59.3 x 60.2 in
Max Subpanel Size
1506 x 1528 mm
Nema Rating
Type 12
Product Family
ProLine
Series
ProLine G2
Size
1600x1600x500 mm
Type
Mild Steel Modular Industrial Enclosures
Weight
404 lb
Width
1,608 mm
Width
63.29 in
Width
1,608
Package Dimensions (L x W x H)
50 IN x 30.5 IN x 70 IN
Package Dimensions (L x W x H)
127 cm x 77.47 cm x 177.8 cm
Package Weight (Imperial)
404.000 L
Package Weight (Metric)
183.254 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

What are the available frame dimensions?

Frame heights range from 600 mm to 2200 mm, with various widths and depths available.

What materials are used in the ProLine G2 frame?

The frame is made of 12 gauge (2.5 mm) roll-formed steel with fully welded solid steel corner blocks.

What types of applications does ProLine G2 support?

ProLine G2 is designed for industrial environments and can accommodate Type 3R and Seismic applications.

What accessories are available for cable management?

Cable management accessories include cable entry cabinets, tie-down brackets, and wire management rails.

What types of doors are available for the enclosure?

Available door types include solid doors, window doors, perforated doors, and overlapping double doors.

What is the maximum weight capacity for the subpanel?

The subpanel can hold greater than 45% more weight than previous models.

What safety features are included with ProLine G2?

Safety features include mechanical and electrical interlocks, disconnect doors, and barrier panels.

What is the purpose of the EMC options?

EMC options are designed to maintain electromagnetic compatibility for sensitive electronic equipment.

What is the maximum load capacity for casters?

Casters can support a maximum load of 1000 lb (453.6 kg) when installed properly.

How to Install the P2KOD16165E PROLINE G2 Enclosure

Installation guide for mounting and securing the P2KOD16165E PROLINE G2 enclosure.

Estimated time: 1h

Tools needed:

Measuring tape, Level, Drill, Screwdriver, Wrench set

Supplies needed:

Mounting hardware, Gasket, Door seals

  1. Prepare the Mounting Location

    Select a suitable location for the enclosure. Ensure the surface is level and capable of supporting the weight of the enclosure and its contents. Measure and mark the mounting hole positions according to the enclosure's dimensions. Refer to the datasheet for specific dimensions and weight.

  2. Mount the Enclosure

    Drill pilot holes at the marked locations. Secure the P2KOD16165E enclosure to the mounting surface using appropriate mounting hardware. Verify that the enclosure is securely fastened and level.

  3. Install Gaskets and Seals

    Apply the provided gasket to the enclosure door or frame according to the instructions. Ensure a proper seal to maintain the enclosure's environmental rating. Check the datasheet for specific gasket placement and type.

  4. Install Internal Components (if applicable)

    If mounting internal components such as backplates or subpanels, follow the specific instructions for those items. Ensure all components are securely fastened within the enclosure.

  5. Wire the Enclosure (if applicable)

    If the enclosure requires wiring for internal equipment, follow all electrical safety precautions. Use appropriate wire gauges and connectors. Refer to the equipment's documentation for specific wiring diagrams and requirements. Ensure all connections are tight and properly insulated.

  6. Close and Secure the Door

    Carefully close the enclosure door, ensuring that no wires or components are pinched. Secure the door using the provided latches or locking mechanism. Verify that the door is properly sealed.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.