nVent P2BGPV166 - ProLine G2 Vented Gland Plate, 1600 x 600, Steel, Light Gray
nVent

P2BGPV166

UPC: 783510310462


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The **nVent ProLine G2 Vented Gland Plate (SKU: P2BGPV166)** is a high-performance industrial component designed to enhance thermal management in electrical enclosures while maintaining robust protection against environmental contaminants. Engineered by nVent, a global leader in thermal management and electrical connectivity solutions, this vented gland plate integrates seamlessly with ProLine G2 systems to provide passive cooling for sensitive electronics without compromising NEMA 12 compliance. The 1600 x 600 mm light gray steel plate features strategically placed aluminum filters, shielded by vented top and bottom plates to facilitate optimal airflow while preventing dust, water, and debris ingress. This solution is ideal for applications where heat dissipation is critical, such as industrial control panels, automation systems, telecommunications hubs, and data centers. A key advantage of the ProLine G2 Vented Gland Plate is its **adjustable foam-gasketed gland**, which allows for secure cable entry while maintaining the enclosure’s integrity. Unlike solid gland plates, this vented design promotes natural convection cooling, reducing the need for active cooling systems and lowering operational costs. The steel construction ensures durability and structural integrity, while the light gray finish provides a professional appearance suitable for both indoor and outdoor installations. It is important to note that while the vented plate and filters are robust, they are not designed to support direct weight or foot traffic—installation should follow manufacturer guidelines to avoid damage. Industries that benefit most from this solution include **manufacturing, oil & gas, renewable energy, and infrastructure**, where electrical enclosures are exposed to harsh conditions yet require reliable thermal performance. Professionals selecting this product should consider the thermal load of their system, the environmental conditions (e.g., humidity, particulate matter), and the need for NEMA 12 compliance. nVent’s ProLine G2 series is trusted for its compatibility with a wide range of enclosures and accessories, making it a versatile choice for engineers and system integrators. Installation is straightforward with standard mounting hardware, and the vented design allows for easy filter replacement or cleaning to maintain long-term performance. By choosing the **nVent ProLine G2 Vented Gland Plate**, businesses can achieve a balance between thermal efficiency and environmental protection, ensuring their critical electronics operate within safe temperature ranges while adhering to stringent industrial standards. This product exemplifies nVent’s commitment to innovation in thermal management, backed by decades of expertise in electrical enclosure solutions.
  • Limited adjustability of plates for access point repositioning; additional gasketing supplied standard
  • Installation hardware included
  • Plinth Base and Vented Plinth Base Covers sold separately
  • Adjustable foam-gasketed gland for secure cable entry
  • Compatible with ProLine G2 systems for seamless integration

Specifications

Application
Controls and Drives; Power Distribution
Cable Entry
Yes
Color
Light Gray
Color Code
RAL 7035
Filter Quantity
2
Filter Size
22.01 x 7.24 in
Filter Size
559 x 184 mm
Finish
Powder Coated
Fits Frame
1600 x 600 mm
Fits Frame
63.00 x 23.62 in
Gland Plate Quantity
2
Material
Mild Steel
Product Family
ProLine
Size
0.68 x 62.60 x 22.05
Thickness
1.9 mm
Thickness
14 ga
Type
External Mounting for ProLine Industrial Enclosures
Weight
93.06 lb
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the P2BGPV166 Controller

This guide provides step-by-step instructions for installing and configuring the P2BGPV166 Controller on a DIN rail.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2BGPV166 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Use terminal connectors to connect the power supply wires to the designated terminals on the controller. Ensure the connections are tight and secure.

  3. Verify the connections

    Use a multimeter to check the voltage at the power supply terminals. Confirm that the voltage matches the specifications outlined in the controller's manual.

  4. Configure the controller settings

    Access the controller's configuration interface using the provided software. Follow the prompts to set up the necessary parameters for your application.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the manual to ensure the controller operates within the desired specifications. Adjust settings as necessary.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.