nVent PTOD1812 - ProLine Overlapping Doors, 68.46x46.89x0.00, Painted
nVent

PTOD1812

UPC: 783510197766


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ProLine Overlapping Doors (SKU: PTOD1812) offer a robust and reliable door solution for industrial enclosures, specifically designed to fit the full-width open fronts of 1200mm wide frames. Manufactured by nVent, a trusted leader in electrical enclosure solutions, these doors provide enhanced protection and accessibility for sensitive equipment. Engineered for durability and performance, the ProLine Overlapping Doors feature a painted finish for corrosion resistance and a professional aesthetic. The overlapping design ensures a superior seal, crucial for maintaining a dust-tight environment within the enclosure, thereby safeguarding internal components from environmental contaminants. This is further enhanced by a sophisticated 3-point roller latch system, operated by a convenient ProLine flush swing handle. This mechanism guarantees a secure closure and easy access when maintenance or adjustments are required. These doors are integral to the ProLine G2 enclosure system, offering modularity and flexibility for various industrial applications. The ProLine G2 platform is renowned for its high load capacity and ease of integration with a wide range of external components, making it a versatile choice for complex electrical and automation projects. The overlapping door design is particularly beneficial in environments where dust ingress is a significant concern, such as manufacturing plants, food and beverage processing facilities, and outdoor control stations. Key features and benefits include: * **Superior Sealing:** The overlapping door design and 3-point roller latch system create a dust-tight seal, protecting sensitive electronics. * **Robust Construction:** Painted finish provides durability and resistance to harsh industrial environments. * **User-Friendly Operation:** Flush swing handle and roller latch system ensure easy and secure operation. * **Modular Integration:** Designed to seamlessly integrate with nVent ProLine G2 enclosure frames. * **Versatile Application:** Ideal for a wide range of industrial control, automation, and power distribution applications. When selecting enclosure doors, professionals prioritize security, environmental protection, and ease of access. The nVent ProLine Overlapping Doors meet these demands with their high-quality construction and thoughtful design. The 1800x1200mm size (approximately 70.2 x 47.2 inches) makes them suitable for larger frame widths, providing ample access for equipment installation and maintenance. The 'Painted' designation indicates a standard industrial finish, ready for deployment in demanding settings. For applications requiring specific certifications or enhanced environmental protection, consulting the full nVent ProLine catalog is recommended.
  • overlapping primary/adjacent door design allows unobstructed access
  • Furnished with a ProLine flush swing handle
  • Removable door bar is included on each door
  • Primary door is hinged on the right side
  • SKU PTOD1812, dimensions 1800x1200mm, manufactured by nVent in the US.

Specifications

Application
Controls and Drives; Power Distribution
Color
Light Gray
Color
Painted
Color Code
RAL 7035
Dimensions
1739 x 1191 mm
Dimensions
68.46 x 46.89 in
Finish
Powder Coated
Fits Frame
1800 x 1200 mm
IP Rating
IP66
Material
Mild Steel
Material
Steel
Modification Services
Yes
Mounting Type
Overlapping
Nema Rating
Type 4X
Product Family
ProLine
Series
ProLine G2
Size
68.46x46.89x0.00 in
Size
1800x1200 mm
Thickness
1.9 mm
Thickness
14 ga
Type
External Mounting for ProLine Industrial Enclosures
Weight
94.5 lb
Package Dimensions (L x W x H)
71 IN x 27.5 IN x 6.75 IN
Package Dimensions (L x W x H)
180.34 cm x 69.85 cm x 17.145 cm
Package Weight (Imperial)
94.500 L
Package Weight (Metric)
42.865 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the PTOD1812 Controller

This guide provides step-by-step instructions for installing and configuring the PTOD1812 Controller on a DIN rail.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the PTOD1812 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Using terminal connectors, connect the power supply wires to the designated input terminals on the PTOD1812. Verify the polarity is correct to avoid damage.

  3. Configure initial settings

    Power on the controller and access the configuration menu using the interface. Set the desired parameters according to your application requirements.

  4. Calibrate the controller

    Follow the calibration procedure outlined in the manual to ensure accurate readings. Use a multimeter to verify output signals during calibration.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.