nVent MCD18104R5 - Modular Double Door, with Plate, Rear Panel, 1800x1000x400mm, Gray, Mild Steel
nVent

MCD18104R5

UPC: 783510490461


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The **nVent MCD18104R5 Modular Double Door Enclosure** is a premium-grade, mild steel floor-standing cabinet engineered for demanding industrial environments where space efficiency and component protection are critical. Designed by **nVent**, a globally trusted leader in thermal management and electrical protection solutions, this enclosure combines robust construction with modular flexibility to meet the rigorous demands of modern industrial, commercial, and utility applications. With a **1800x1000x400mm** footprint and **IP55-rated protection**, the MCD18104R5 ensures reliable safeguarding of sensitive electrical and electronic components against dust ingress, water jets, and mechanical stress—ideal for installations in confined or high-traffic areas where space is at a premium. **Key Features and Benefits** The **double-door design** of the MCD18104R5 is a standout feature, offering significant advantages over single-door enclosures. By splitting access across two doors, this configuration minimizes the spatial footprint required for door swing, making it ideal for installations in tight corridors, server rooms, or industrial control panels where floor space is limited. Additionally, the load-bearing capacity is distributed across both doors, enhancing structural integrity and reducing stress on hinges and seals during frequent access or heavy component loading. This design also facilitates easier cable management and internal organization, as technicians can access different sections of the enclosure simultaneously without obstruction. **Industry-Leading Protection and Durability** Crafted from **mild steel with a durable gray finish**, the MCD18104R5 delivers exceptional durability and corrosion resistance, ensuring long-term performance in harsh environments. The **IP55 protection rating** confirms its resistance to dust accumulation and low-pressure water jets, making it suitable for both indoor and sheltered outdoor applications. This level of ingress protection is essential in industries such as manufacturing, utilities, telecommunications, and data centers—where equipment must operate reliably despite exposure to particulates, humidity, or incidental moisture. **Modularity and Scalability for Future Growth** As part of nVent’s **MCD series**, the MCD18104R5 is designed for modular expansion and system integration. The enclosure supports the addition of side panels, roof sections, and mounting plates, allowing professionals to customize the configuration based on evolving operational needs. Whether expanding a control system, upgrading network infrastructure, or consolidating multiple devices into a single secure housing, the modular architecture ensures seamless scalability without compromising structural integrity or protection standards. **Applications Across Diverse Sectors** This enclosure is purpose-built for a wide range of critical applications: - **Industrial Automation & Control Systems**: Safeguard PLCs, HMIs, and variable frequency drives (VFDs) in manufacturing plants and processing facilities. - **Power Distribution & Electrical Panels**: House circuit breakers, relays, and distribution boards in utility substations or commercial buildings. - **Telecommunications & IT Infrastructure**: Protect servers, switches, and networking equipment in data centers or telecom shelters. - **Renewable Energy Systems**: Enclose inverters, battery management systems, and monitoring equipment in solar or wind power installations. - **Transportation & Infrastructure**: Secure signaling systems, traffic control devices, and surveillance electronics in rail, road, or airport environments. **Engineered for Professional Installation and Maintenance** The MCD18104R5 is designed with installer convenience and long-term reliability in mind. Pre-drilled mounting holes and removable rear panels simplify wall or floor anchoring, while the double-door configuration allows for easier access during commissioning, troubleshooting, and upgrades. The **gray powder-coated finish** not only enhances corrosion resistance but also provides a professional appearance suitable for visible installations in clean rooms, labs, or customer-facing facilities. **Why Choose nVent?** With over a century of innovation in thermal and electrical protection, **nVent** is a brand engineers and facility managers trust for performance, safety, and compliance. The MCD series reflects the company’s commitment to delivering modular, high-integrity enclosures that meet international standards, including IEC 62208 and UL Type 12. Backed by comprehensive technical support, global distribution, and a reputation for durability, nVent enclosures like the MCD18104R5 provide peace of mind in mission-critical applications where failure is not an option. **Ideal for Professionals Who Demand More** Whether you're designing a new control room, retrofitting an aging electrical panel, or upgrading telecom infrastructure, the **nVent MCD18104R5** delivers the space-saving flexibility, protection, and scalability your project requires. Choose a solution that combines smart engineering with trusted performance—choose nVent.
  • Material: Frame: 1.5 mm painted steel. Doors: 2 mm painted steel. Rear, roof and side panels: 1.5 mm painted steel. Mounting plate: 3 mm galvanized steel. Bottom plates: 1 mm galvanized steel.
  • Frame: Seam welded reversed open profiles with 25 mm hole pattern, according to DIN 43660. Including integrated external hole pattern.
  • Doors: Mounted with four hinges. Including door frame with 25 mm hole pattern. Doors cannot be reversed. Separate doors to be ordered for left hand door locking.
  • Rear panel: Fitted by M6 torx screws. Standard facilities for rear doors mounting. Split rear panels in 1600 mm wide enclosures. RD version comes with rear door instead of rear panel.
  • Side panels: Supplied as an accessory.
  • Roof panel: Removable.
  • Lock: Espagnolette 4-point locking system in the main door and 2-point locking system in the slave door. Standard double-bit lock with 3 mm insert. Standard inserts, cylinders, lift handles and T-handles are available as accessories.
  • Bottom plates: Consists of three or four (D>600) pieces.
  • Mounting plate: Double folded and slides into position. Adjustable in depth by steps of 25 mm, with the MPD02 accessory. Supplied, attached on the outside of the enclosure packaging.
  • Earthing: All panels are earthed through their fittings and equipped with a separate earthing stud.

Specifications

Application
Controls and Drives;Factory Automation and Process Control
Body Thickness
1.5 mm
Body Thickness
16 ga
Cable Entry
No
Color
Light Gray
Color
Gray
Color
Grey
Color Code
RAL 7035
Construction
Body: 16 gauge Door: 14 gauge
Depth
15.75
Depth
400
Depth
400 mm
Door Thickness
14 ga
Finish
Powder Coating
Finish
Powder Coated
Height
1,800 mm
Height
70.87
Height
1,800
Material
Mild Steel
Max Mounting Depth
14.13 in
Max Mounting Depth
11.1 in
Mounting
Free Standing
Mounting Plate Height
1,694;66.7 mm;mm
Mounting Plate Included
Yes
Mounting Plate Width
35.2 in
NEMA Rating
12
NEMA Rating
NEMA Type 12
Protection Rating
NEMA Type 12
Rear Door Included
No
Rear Panel Included
Yes
Size
70.87 x 39.37 x 15.75 inch
Type
Mild Steel Modular Industrial Enclosures
Weight
350.8 lb
Width
39.37
Width
1,000
Width
1,000 mm
Package Dimensions (L x W x H)
71.24 IN x 39.75 IN x 40 IN
Package Dimensions (L x W x H)
180.9496 cm x 100.965 cm x 101.6 cm
Package Weight (Imperial)
350.800 L
Package Weight (Metric)
159.123 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the MCS20085R5 Controller

This guide provides step-by-step instructions for installing and configuring the MCS20085R5 Controller, ensuring proper mounting, wiring, and initial setup.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors, Floor plate (if required)

  1. Mount the controller

    Secure the MCS20085R5 Controller to the designated mounting surface using the provided mounting screws. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Use wire connectors to connect the power and signal wires to the appropriate terminals on the controller. Ensure all connections are secure and insulated.

  3. Verify the installation

    Use a multimeter to check the voltage at the controller terminals to ensure proper power supply. Confirm that all connections are correct and secure.

  4. Configure the controller settings

    Access the controller's configuration interface and input the necessary parameters for operation. Follow the manufacturer's guidelines for specific settings.

  5. Calibrate the controller

    Perform any required calibration procedures as outlined in the user manual to ensure optimal performance of the MCS20085R5 Controller.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.