Authorized nVent Distributor
nVent MCF18105R5 - Flange Mount Disconnect, MCF, 1800x1000x500mm, Zinc Plated, Mild Steel

nVent MCF18105R5 Flange Mount Disconnect, MCF, 1800x1000x500mm, Zinc Plated, Mild Steel

UPC: 783510493011


Documents & Media
Installation InstructionsSpecification SheetVideo ClipManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent MCF18105R5 Flange Mount Disconnect Enclosure is a heavy-duty, floor-standing industrial enclosure designed for secure housing of electrical controls, switchgear, and instrumentation. Constructed from 1.5 mm painted mild steel for the frame, rear, roof, and side panels, and 2 mm painted mild steel for the doors, this enclosure delivers exceptional durability in demanding environments. The zinc-plated finish enhances corrosion resistance, making it ideal for industrial, manufacturing, power generation, water treatment, and automation applications. Key features include an IP55 protection rating for dust and water ingress resistance, Type 12 and 13 compliance for industrial safety, and an IK10 rating for high-impact resistance. The enclosure incorporates a 25 mm DIN 43660 hole pattern in the frame and door frame for flexible component mounting, with a universal pre-machined cut-out on the right-hand door to simplify switch installation. The flange door design allows for surface mounting and is secured with four heavy-duty hinges, featuring internal locking for enhanced security. The mounting plate is 3 mm galvanized steel, and bottom plates are 1 mm galvanized steel, providing a stable foundation for equipment. The MCF18105R5 is engineered for compliance with door interlocking and main switch regulations, ensuring operational safety and reliability.
  • Material: Frame: 1.5 mm painted steel. Doors: 2 mm painted steel. Rear, roof and side panels: 1.5 mm painted steel. Mounting plate: 3 mm galvanized steel. Bottom plates: 1 mm galvanized steel.
  • Frame: Seam welded reversed open profiles with 25 mm hole pattern, according to DIN 43660. Including integrated external hole pattern.
  • Door: Mounted with four hinges. Including door frame with 25 mm hole pattern. Door can not be reversed. Flange door: Surface mounted with hinges, locked from the inside, including universal cut-out.
  • Rear panel: Fitted by M6 torx screws. Standard facilities for rear door mounting.
  • Side panels: Supplied as an accessory.
  • Roof panel: Removable.
  • Lock: Lock, left door: Espagnolette 4-point locking system. Does not interfere with the enclosure inner space. Standard double-bit lock with 3 mm insert. Standard inserts, cylinders, lift handles and T-handles are available as accessories. Lock, right doo
  • Bottom plates: Consists of three pieces
  • Mounting plate: Double folded and adjustable in depth by steps of 25 mm, with the MPD02 accessory. Supplied, attached on the outside of the enclosure packaging.
  • Earthing: All panels are earthed through their fittings and are equipped with a separate earthing stud.

Specifications

Application
Controls and Drives;Factory Automation and Process Control
Body Thickness
1.5 mm
Body Thickness
16 ga
Cable Entry
No
Color
Light Gray
Color
Gray
Color
Grey
Color Code
RAL 7035
Construction
Body: 16 gauge Door: 14 gauge
Depth
500 mm
Depth
19.69 in
Depth
500
Door Thickness
14 ga
Finish
Powder Coated
Finish
Powder Coating
Height
1,800 mm
Height
70.87 in
Height
1,800
Material
Mild Steel
Mounting
Free Standing
Mounting Plate Height
1,694;66.69 mm;mm
Mounting Plate Width
35.2 in
NEMA Rating
12
NEMA Rating
NEMA Type 12
Protection Rating
NEMA Type 12
Size
70.87 x 39.37 x 19.69 inch
Type
Mild Steel Modular Industrial Disconnect Enclosures
Weight
345.55 lb
Width
999 mm
Width
1,000
Width
39.37 in
Package Dimensions (L x W x H)
39.75 IN x 20.31 IN x 71.24 IN
Package Dimensions (L x W x H)
100.965 cm x 51.5874 cm x 180.9496 cm
Package Weight (Imperial)
345.550 L
Package Weight (Metric)
156.742 kg
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

What are the overall dimensions of the MCF18105R5 enclosure?

The enclosure has a height of 70.87 inches, a width of 39.37 inches, and a depth of 19.69 inches.

What industry standards does the MCF18105R5 enclosure comply with?

It is UL 508A Listed, cUL Listed, NEMA/EEMAC Type 12, and complies with IEC 62208 IP55.

What materials are used in the construction of this enclosure?

The frame, rear, roof, and side panels are 1.5 mm painted steel, doors are 2 mm painted steel, and the mounting plate is 3 mm galvanized steel.

What is the protection rating of the MCF18105R5 enclosure?

The enclosure complies with IP 55, TYPE 12, and IK 10 protection ratings.

How is the mounting plate installed and adjusted?

The mounting plate is double folded and adjustable in depth by steps of 25 mm using the MPD02 accessory.

What type of locking system does the enclosure feature?

The left door has an Espagnolette 4-point locking system with a standard double-bit lock. The right door has top and bottom locks with a double-bit 3 mm insert.

Are side panels included with the enclosure?

No, SPM mild steel side panels must be ordered separately to close the cabinets and maintain the protection rating.

How is the enclosure delivered?

It is delivered on a pallet identical to the enclosure width, with fitted doors, rear panel, roof panel, bottom plates, mounting plate, and door frame.

What is the finish and color of the enclosure?

The enclosure has a RAL 7035 structured powder coating in a light gray color.

What is the body and door thickness of the enclosure?

The body thickness is 16ga, and the door thickness is 14ga.

How to Install the MCF18105R5 Controller

This guide provides step-by-step instructions for mounting and wiring the MCF18105R5 controller securely and safely.

Estimated time: 45m

Tools needed:

Screwdriver, Torque wrench, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Cage nuts, Terminal connectors

  1. Prepare the mounting area

    Ensure the mounting surface is clean and free from debris. If mounting on a combustible surface, install a floor plate of at least 1.43 mm galvanized or 1.6 mm uncoated steel extending at least 150 mm beyond the equipment on all sides.

  2. Mount the controller

    Secure the MCF18105R5 controller to the mounting plate using the provided mounting screws. Ensure the controller is level and firmly attached. Use a torque wrench to tighten screws to the specified torque of 4.5-5 Nm.

  3. Connect the wiring

    Connect the power and signal wires to the designated terminals on the controller. Use wire strippers to prepare the wire ends and ensure secure connections. Verify connections with a multimeter to ensure proper voltage and continuity.

  4. Configure the controller

    Power on the controller and access the configuration settings. Follow the manufacturer's instructions to set parameters such as communication protocols and operational modes.

  5. Calibrate the controller

    Perform calibration as per the manufacturer's guidelines. This may involve adjusting settings based on the specific application requirements and verifying output signals.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.