nVent MCS20088R5 - Modular Single Door, MCS with Plate, 2000x800x800mm, Light Gray, Mild Steel
nVent

MCS20088R5

UPC: 783510496227


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent MCS20088R5 is a 2000x800x800mm floor-standing enclosure constructed from mild steel with a light gray finish. It offers IP55 ingress protection, safeguarding internal components from dust and low-pressure water jets. This modular single-door enclosure is designed for industrial applications requiring reliable protection for electrical and electronic equipment. Its substantial dimensions provide ample space for control panels, automation components, and other critical hardware. The mild steel construction offers a balance of strength and cost-effectiveness, suitable for various indoor and semi-outdoor environments. Applications include manufacturing, renewable energy, telecommunications, and water/wastewater treatment facilities where equipment durability is essential. The MCS20088R5 is part of nVent's MCS series, known for engineered reliability and modularity. Its design facilitates installation and maintenance, with pre-drilled surfaces for standard mounting. Compatible with various nVent accessories for customization. SKU: MCS20088R5. Country of Origin: US.
  • Material: Frame: 1.5 mm painted steel. Door: 2 mm painted steel. Rear, roof and side panels: 1.5 mm painted steel. Mounting plate: 3 mm galvanized steel. Bottom plates: 1 mm galvanized steel.
  • Frame: Seam welded reversed open profiles with 25 mm hole pattern, according to DIN 43660. Including integrated external hole pattern.
  • Door: Mounted with four hinges allowing left or right hand opening. Including door frame with 25 mm hole pattern.
  • Rear panel: Fitted by M6 torx screws. Standard facilities for rear door mounting. RD version comes with rear door instead of rear panel.
  • Side panels: Supplied as an accessory.
  • Roof panel: Removable.
  • Lock: Espagnolette 4-point locking system. Does not interfere with the enclosure inner space. Standard double-bit lock with 3 mm insert. Standard inserts, cylinders, lift handles and T-handles are available as accessories.
  • Bottom plates: Consists of three or four (D>600) pieces.
  • Mounting plate: Double folded and slides into position. Adjustable in depth by steps of 25 mm, with the MPD02 accessory. Supplied, attached on the outside of the enclosure packaging.
  • Earthing: All panels are earthed through their fittings and are equipped with a separate earthing stud.

Specifications

Application
Controls and Drives;Factory Automation and Process Control
Body Thickness
1.5 mm
Body Thickness
16 ga
Cable Enclosures Included
No
Cable Entry
No
Color
Gray
Color
Grey
Color
Light Gray
Color Code
RAL 7035
Construction
Body: 16 gauge Door: 14 gauge
Depth
800 mm
Depth
31.5
Depth
800
Door Thickness
14 ga
Finish
Powder Coated
Finish
Powder Coating
Height
2,000 mm
Height
78.74
Height
2,000
Material
Mild Steel
Max Mounting Depth
29.88 in
Max Mounting Depth
11.1 in
Mounting
Free Standing
Mounting Plate Height
1,894;74.57 mm;mm
Mounting Plate Included
Yes
Mounting Plate Width
27.32 in
NEMA Rating
12
NEMA Rating
NEMA Type 12
Protection Rating
NEMA Type 12
Rear Door Included
No
Rear Panel Included
Yes
Size
78.74 x 31.5 x 31.5 inch
Type
Mild Steel Modular Industrial Enclosures
Weight
323.05 lb
Weight
32 lbs./100ft
Weight
286.6 lb
Width
31.5
Width
800
Width
800 mm
Package Dimensions (L x W x H)
32.12 IN x 31.87 IN x 79.12 IN
Package Dimensions (L x W x H)
81.5848 cm x 80.9498 cm x 200.9648 cm
Package Weight (Imperial)
323.050 L
Package Weight (Metric)
146.536 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the MCS20088R5 Controller

This guide provides step-by-step instructions for installing and configuring the MCS20088R5 Controller, ensuring proper setup and functionality.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors, DIN rail

  1. Mount the controller

    Secure the MCS20088R5 Controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Use wire connectors to connect the power supply and input/output wires to the designated terminals on the controller. Verify that all connections are secure and properly insulated.

  3. Configure the controller settings

    Power on the controller and use the programming interface to set the desired parameters. Follow the manufacturer's guidelines for configuration options.

  4. Calibrate the controller

    Perform a calibration check by following the calibration procedure outlined in the user manual. Ensure that all readings are within acceptable ranges.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.