Protect your critical industrial components with the nVent MAS Mild Steel Single Door Enclosure (SKU: MAS0606040PER5). Engineered for demanding environments, this robust enclosure offers superior protection against dust, water, and other contaminants, ensuring the longevity and reliability of your sensitive equipment. With an IP66 protection rating, the MAS enclosure is designed to withstand high-pressure water jets and dust ingress, making it an ideal solution for a wide array of industrial applications. The nVent MAS series is renowned for its availability in a comprehensive range of standard sizes, allowing for quick and efficient deployment without compromising on protection. This particular model, measuring 600x600x400mm, provides ample space for various control panels, electrical components, and automation systems. Constructed from durable mild steel and finished in a light gray hue, it offers both structural integrity and a professional aesthetic suitable for any industrial setting. Key benefits of the nVent MAS enclosure include: * **Uncompromising Protection:** The IP66 rating guarantees protection against dust and powerful water jets, significantly reducing the risk of component failure and costly downtime. This is crucial in sectors like manufacturing, food and beverage processing, and outdoor installations where environmental factors are a constant concern. * **Durable Construction:** Crafted from high-quality mild steel, these enclosures are built to endure harsh industrial conditions, offering long-term performance and safeguarding your investments. * **Versatile Application:** The MAS range is exceptionally versatile, suitable for housing PLCs, HMI panels, motor controls, power distribution units, and other essential electrical and electronic equipment across diverse industries. * **Ease of Installation:** Designed for straightforward wall mounting, the MAS enclosures facilitate quick integration into existing infrastructure, minimizing installation time and labor costs. * **Reliability:** nVent is a trusted leader in enclosure solutions, known for its commitment to quality and innovation. Choosing nVent ensures you are selecting a product that meets stringent industry standards and delivers dependable performance. Beyond its core protective functions, the single-door design of the MAS0606040PER5 allows for convenient access to internal components for maintenance, upgrades, or troubleshooting. The absence of a mounting plate in this specific SKU (MAS no Plate) offers flexibility for users to integrate their preferred internal mounting solutions, whether it be DIN rails, custom panels, or other accessories. This adaptability further enhances its suitability for bespoke industrial automation projects. By investing in the nVent MAS Mild Steel Enclosure, you are not just purchasing a protective housing; you are investing in operational continuity, component safety, and the overall efficiency of your industrial processes. Preventing environmental ingress is paramount in maintaining optimal operating conditions for electrical and electronic systems, and the MAS series excels in this regard, offering peace of mind and robust performance.
  • Body: Folded and seam welded. Four 8.5 mm diameter holes for wall fixing, pressed out in 20.4 mm diameter × 2 mm depressions, to allow air circulation around the rear part of the enclosure.
  • Gland Plate Opening: Situated at the far rear of the enclosure, to make cabling onto the mounting plate easier.
  • Protection: Complies with IP 66, TYPE 4, 12, IK 10. For outdoor installation, the use of a rain Hood, ARF, and 100% polyester paint coating plus corrosion protection primer is recommended. Resistance to corrosion must be taken into consideration for outdo
  • Mounting plate: The mounting plate is marked vertically at 10 mm intervals, for easy horizontal positioning of equipment. On the top and bottom there are holes to facilitate cable fixing. Fixed onto M8 press welded studs to the rear of the enclosure. All
  • Material: Body: 1.2 mm mild steel for enclosures with a depth of 155 mm / 1.4 mm for enclosures with a depth of 210 or 260 mm / 1.5 mm for enclosures with a depth of 300 or 400 mm, or if a height or width is 1000 mm or greater. Gland plate: 1.4 mm mild st
  • Lock: nVent HOFFMAN customized double-bit 3 mm lock, with 90° movement and anti-vibration mechanism. Two locks for 600 mm high to 800 mm high enclosures. Espagnolette three point locking for 1000 mm high enclosures and above. Other inserts are available a
  • Finish: RAL 7035 structured powder coating.
  • Door: Surface mounted with 130° opening. Concealed removable hinges with captive pin. Hinges can be mounted to allow left or right hand opening. Inner M6 welded studs to mount door profiles MMDP, see delivery. Sealing is ensured by an injected one piece p
  • Delivery: Enclosure with door and mounting plate (not included for item numbers ending with PER5). For height 600 mm and above, two MMDP door mounting profiles. Gland plate(s) with gasket(s), plastic double-bit 3 mm key, and mounting accessories. Metallic
  • Mounting plate: All sides, from 800 mm and above, are strengthened by folded edges

Specifications

Color
Light Gray
IP Rating
IP66
Material
Mild Steel
Mounting Type
Wall Mount
Series
MAS
Size
600x600x400 mm
Package Dimensions (L x W x H)
24 IN x 24 IN x 24.25 IN
Package Dimensions (L x W x H)
60.96 cm x 60.96 cm x 61.595 cm
Package Weight (Imperial)
55.400 L
Package Weight (Metric)
25.129 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Prepare for and Secure MAS0806021PER5 Installation

This guide outlines critical safety precautions and fastener specifications for mounting MAS0806021PER5, particularly concerning combustible surfaces and enclosure integrity.

Estimated time: 10m

Tools needed:

T25 Torx driver

Supplies needed:

1.43 mm galvanized steel floor plate, 1.6 mm uncoated steel floor plate, M4.8x9.5 screws, M8 fasteners

  1. Prepare Mounting Surface for Combustible Materials

    WARNING: If mounting MAS0806021PER5 on or over a combustible surface, a floor plate must be installed. This plate shall be at least 1.43 mm galvanized or 1.6 mm uncoated steel, extending at least 150 mm beyond the equipment on all sides.

  2. Maintain Enclosure Environmental Integrity

    WARNING: To preserve the environmental integrity of the MAS0806021PER5 enclosure, use only devices with matching environmental ratings when closing openings in a customized enclosure.

  3. Select Appropriate Fasteners and Tools

    For securing MAS0806021PER5, utilize fasteners such as M4.8x9.5 screws and M8 bolts as required by the specific mounting points. A T25 Torx driver may be necessary for installation.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.