The nVent MAS0606030R5 single-door wall-mount enclosure is a robust, off-the-shelf solution engineered for industrial environments where protection against dust, water, and mechanical stress is critical. Constructed from high-grade mild steel with a durable light gray powder-coated finish, this enclosure (SKU: MAS0606030R5) delivers IP66-rated ingress protection, ensuring reliable performance in harsh conditions. Part of nVent’s MAS series, this enclosure is designed to safeguard sensitive electrical and electronic components from environmental contaminants, reducing the risk of component failure and unplanned downtime. **Key Features and Benefits** The MAS0606030R5 stands out for its **IP66 certification**, which guarantees complete protection against dust ingress and powerful water jets from any direction—ideal for outdoor installations, washdown areas, or industrial facilities exposed to moisture and particulates. The **single-door design** with a removable front panel simplifies access for maintenance, while the **mild steel construction** provides superior strength and durability without excessive weight. The **600x600x300mm dimensions** offer ample internal space for mounting circuit breakers, relays, PLCs, or other control components, with the 300mm depth accommodating thicker assemblies. **Industry Applications and Use Cases** This enclosure is a versatile choice for a wide range of industries, including **manufacturing, oil and gas, water treatment, food and beverage, and renewable energy**. In **automotive plants**, it can house motor control centers or variable frequency drives, while in **pharmaceutical or food processing facilities**, it protects sensitive instrumentation from washdown procedures. For **renewable energy projects**, such as solar or wind farms, the MAS0606030R5 ensures reliable operation in outdoor enclosures exposed to weather extremes. Its **wall-mount design** makes it suitable for both indoor and outdoor installations, with optional mounting brackets available for added stability. **Why Choose nVent for Industrial Enclosures?** nVent is a globally recognized leader in thermal management and electrical protection solutions, with decades of expertise in designing enclosures that meet the demands of modern industrial applications. The MAS series, including the MAS0606030R5, reflects nVent’s commitment to **durability, compliance, and ease of integration**. These enclosures are **UL-listed and CE-marked**, ensuring they meet international safety and performance standards. Professionals trust nVent for its **consistent quality, fast lead times, and comprehensive technical support**, making it a preferred choice for engineers and facility managers. **Installation and Compatibility Considerations** The MAS0606030R5 is designed for straightforward installation, with **pre-drilled mounting holes** and a **hinged door** for easy access. The **light gray finish** not only provides corrosion resistance but also reduces heat absorption in high-temperature environments. For applications requiring additional protection, nVent offers compatible accessories such as **ventilation grilles, gland plates, and cable entry systems**. When selecting an enclosure, consider factors like **thermal dissipation, internal component layout, and future expansion needs**—the MAS0606030R5’s spacious interior accommodates these requirements while maintaining IP66 integrity. **Long-Term Reliability and Cost Efficiency** By preventing dust and moisture ingress, the MAS0606030R5 minimizes the risk of **corrosion, short circuits, and component degradation**, leading to **lower maintenance costs and extended equipment lifespan**. Its **off-the-shelf availability** reduces procurement lead times, while the **modular design** allows for easy upgrades or reconfiguration. Whether deployed in a **factory automation system, a wastewater treatment plant, or a remote telecom site**, this enclosure delivers **uncompromising protection and operational reliability**. Trust the nVent MAS0606030R5 to safeguard your critical electrical and electronic assets—where performance, durability, and compliance matter most.
  • Body: Folded and seam welded. Four 8.5 mm diameter holes for wall fixing, pressed out in 20.4 mm diameter × 2 mm depressions, to allow air circulation around the rear part of the enclosure.
  • Gland Plate Opening: Situated at the far rear of the enclosure, to make cabling onto the mounting plate easier.
  • Protection: Complies with IP 66, TYPE 4, 12, IK 10. For outdoor installation, the use of a rain Hood, ARF, and 100% polyester paint coating plus corrosion protection primer is recommended. Resistance to corrosion must be taken into consideration for outdo
  • Mounting plate: The mounting plate is marked vertically at 10 mm intervals, for easy horizontal positioning of equipment. On the top and bottom there are holes to facilitate cable fixing. Fixed onto M8 press welded studs to the rear of the enclosure. All
  • Material: Body: 1.2 mm mild steel for enclosures with a depth of 155 mm / 1.4 mm for enclosures with a depth of 210 or 260 mm / 1.5 mm for enclosures with a depth of 300 or 400 mm, or if a height or width is 1000 mm or greater. Gland plate: 1.4 mm mild st
  • Lock: nVent HOFFMAN customized double-bit 3 mm lock, with 90° movement and anti-vibration mechanism. Two locks for 600 mm high to 800 mm high enclosures. Espagnolette three point locking for 1000 mm high enclosures and above. Other inserts are available a
  • Finish: RAL 7035 structured powder coating.
  • Door: Surface mounted with 130° opening. Concealed removable hinges with captive pin. Hinges can be mounted to allow left or right hand opening. Inner M6 welded studs to mount door profiles MMDP, see delivery. Sealing is ensured by an injected one piece p
  • Delivery: Enclosure with door and mounting plate (not included for item numbers ending with PER5). For height 600 mm and above, two MMDP door mounting profiles. Gland plate(s) with gasket(s), plastic double-bit 3 mm key, and mounting accessories. Metallic
  • Mounting plate: All sides, from 800 mm and above, are strengthened by folded edges

Specifications

Application
Controls and Drives;Factory Automation and Process Control
Application
Factory Automation and Process Control; Controls and Drives
Body Thickness
1.5 mm
Body Thickness
16 ga
Cable Entry
No
Color
Light Gray
Color
Gray
Color
Grey
Color Code
RAL 7035
Construction
Body: 16 gauge Door: 16 gauge
Cubic Capacity
4 in3
Cubic Capacity
65548.4 mm3
Depth
300 mm
Depth
11.81 in
Door Thickness
14 ga
Door Thickness
1.5 mm
Door Thickness
16 ga
Finish
Powder Coated
Gland Plate Opening Depth
3.78 in
Gland Plate Opening Width
12.2 in
Gland Plate Opening Width
20.08 in
Gland Plate Type
4
Height
600 mm
Height
23.62 in
Insulation
No
IP Rating
IP66
Latch Quantity
2
Material
Mild Steel
Material Quality
Mild Steel
Max Mounting Depth
11.1 in
Mounting
Wall Mounted
Mounting Plate Included
Yes
Mounting Type
Wall-mount
NEMA Rating
12;4
NEMA Rating
NEMA Type 4 NEMA Type 12 NEMA Type 13
Number of Gland Plate Openings
1
Number Of Outlet
1
Panel Size
22.44 x 21.65 in
Panel Size
72.00 x 72.00 in
Protection Rating
NEMA Type 4
Series
MAS
Size
600x600x300mm
Size
23.62 x 23.62 x 11.81 inch
Style
With Mounting Plate
Type
Mild Steel Wall Mounted Industrial Enclosures
Weight
57.35 lb
Weight
32 lbs./100ft
Width
23.62 in
Width
600 mm
With or Without Panel
With
Package Dimensions (L x W x H)
24 IN x 24 IN x 12.44 IN
Package Dimensions (L x W x H)
60.96 cm x 60.96 cm x 31.5976 cm
Package Weight (Imperial)
57.350 L
Package Weight (Metric)
26.014 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the MAS0606030R5 Controller

This guide provides step-by-step instructions for installing and configuring the MAS0606030R5 Controller on a DIN rail.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Prepare the installation area

    Ensure the installation area is clean and free of debris. If mounting on a combustible surface, install a floor plate of at least 1.43 mm galvanized or 1.6 mm uncoated steel, extending at least 150 mm beyond the equipment on all sides.

  2. Mount the controller

    Secure the MAS0606030R5 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  3. Connect the wiring

    Use terminal connectors to connect the power supply and input/output wires to the controller. Verify that all connections are secure and correctly oriented.

  4. Configure the controller

    Power on the controller and use the configuration software to set the necessary parameters for your application. Follow the on-screen instructions to complete the setup.

  5. Calibrate the controller

    Perform any required calibration procedures as specified in the user manual. Use a multimeter to verify output signals and ensure proper functionality.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.