Overview

The nVent MAS0604015PER5 single door wall-mount enclosure is a robust, off-the-shelf solution designed to protect critical electrical and electronic components in demanding industrial environments. Engineered from high-quality mild steel with a durable light gray finish, this enclosure meets IP66 standards, ensuring superior resistance to water ingress and dust accumulation. With dimensions of 600x400x155mm, it provides ample space for housing control panels, automation systems, and other sensitive equipment while maintaining a compact footprint for efficient wall mounting. This enclosure is part of nVent’s renowned MAS series, a trusted range of enclosures known for their reliability, durability, and ease of installation. The single-door design facilitates quick access for maintenance and troubleshooting, reducing downtime and operational disruptions. The IP66 rating guarantees protection against heavy seas or powerful jets of water, making it ideal for outdoor installations, manufacturing floors, and other harsh environments where moisture and particulate contamination are concerns. Industries such as manufacturing, oil and gas, utilities, and transportation rely on nVent MAS enclosures to safeguard vital infrastructure. Whether deployed in process control systems, telecommunications hubs, or renewable energy installations, these enclosures deliver consistent performance under challenging conditions. Professionals select the MAS0604015PER5 for its combination of strength, corrosion resistance, and compliance with international protection standards, ensuring long-term reliability and reduced risk of component failure. Installation is straightforward, with pre-drilled mounting holes and a design optimized for wall mounting. The enclosure’s construction minimizes the risk of deformation or damage during handling, while its modular design allows for easy integration with accessories such as gland plates, ventilation units, and locking mechanisms. nVent’s commitment to quality is reflected in every aspect of this product, from material selection to manufacturing processes, ensuring that it meets the rigorous demands of industrial applications. By choosing the nVent MAS0604015PER5, engineers and facility managers invest in a solution that enhances system longevity, reduces maintenance costs, and supports operational continuity. With a country of origin in the US, this enclosure benefits from nVent’s global expertise in thermal management and electrical protection, making it a preferred choice for professionals who prioritize performance and reliability in their projects.
  • Body: Folded and seam welded. Four 8.5 mm diameter holes for wall fixing, pressed out in 20.4 mm diameter × 2 mm depressions, to allow air circulation around the rear part of the enclosure.
  • Gland Plate Opening: Situated at the far rear of the enclosure, to make cabling onto the mounting plate easier.
  • Protection: Complies with IP 66, TYPE 4, 12, IK 10. For outdoor installation, the use of a rain Hood, ARF, and 100% polyester paint coating plus corrosion protection primer is recommended. Resistance to corrosion must be taken into consideration for outdo
  • Mounting plate: The mounting plate is marked vertically at 10 mm intervals, for easy horizontal positioning of equipment. On the top and bottom there are holes to facilitate cable fixing. Fixed onto M8 press welded studs to the rear of the enclosure. All
  • Material: Body: 1.2 mm mild steel for enclosures with a depth of 155 mm / 1.4 mm for enclosures with a depth of 210 or 260 mm / 1.5 mm for enclosures with a depth of 300 or 400 mm, or if a height or width is 1000 mm or greater. Gland plate: 1.4 mm mild st
  • Lock: nVent HOFFMAN customized double-bit 3 mm lock, with 90° movement and anti-vibration mechanism. Two locks for 600 mm high to 800 mm high enclosures. Espagnolette three point locking for 1000 mm high enclosures and above. Other inserts are available a
  • Finish: RAL 7035 structured powder coating.
  • Door: Surface mounted with 130° opening. Concealed removable hinges with captive pin. Hinges can be mounted to allow left or right hand opening. Inner M6 welded studs to mount door profiles MMDP, see delivery. Sealing is ensured by an injected one piece p
  • Delivery: Enclosure with door and mounting plate (not included for item numbers ending with PER5). For height 600 mm and above, two MMDP door mounting profiles. Gland plate(s) with gasket(s), plastic double-bit 3 mm key, and mounting accessories. Metallic
  • Mounting plate: All sides, from 800 mm and above, are strengthened by folded edges

Specifications

Application
Controls and Drives;Factory Automation and Process Control
Body Thickness
16 ga
Body Thickness
18 ga
Color
Light Gray
Color Code
RAL 7035
Depth
155 mm
Depth
6.1 in
Door Thickness
14 ga
Door Thickness
16 ga
Finish
Powder Coated
Gland Plate Opening Depth
2.2 in
Gland Plate Opening Depth
3.78 in
Gland Plate Opening Width
12.2 in
Height
23.62 in
Height
600 mm
IP Rating
IP66
Latch Quantity
2
Material
Mild Steel
Material Quality
Mild Steel
Mounting Plate Included
No
Mounting Type
Wall-mount
Number of Gland Plate Openings
1
Protection Rating
NEMA Type 4
Series
MAS
Size
600x400x155mm
Type
Mild Steel Wall Mounted Industrial Enclosures
Weight
22.9 lb
Weight
32 lbs./100ft
Width
400 mm
Width
15.75 in
Package Dimensions (L x W x H)
24 IN x 16.12 IN x 16.37 IN
Package Dimensions (L x W x H)
60.96 cm x 40.9448 cm x 41.5798 cm
Package Weight (Imperial)
22.900 L
Package Weight (Metric)
10.387 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

What is the IP protection degree of the MAS enclosure range?

The MAS enclosure range has an IP 66 protection degree, preventing water and dust from entering.

What industry standards does the MAS0604015PER5 enclosure comply with?

It complies with UL 508A Listed Type 4, 12; cUL Listed Type 12; NEMA/EEMAC Type 4, 12; CSA Type 4, 12; IEC 62208 IP66; and CE, UK CA, UL, DNV.

What material is the MAS0604015PER5 enclosure body made of?

The enclosure body is made of 1.2 mm mild steel, equivalent to 18ga thickness.

What is the thickness of the door on this enclosure?

The door thickness is 1.2 mm mild steel, equivalent to 16ga.

What type of lock mechanism does the enclosure use?

It uses an nVent HOFFMAN customized double-bit 3 mm lock with a 90° movement and anti-vibration mechanism.

Does the MAS0604015PER5 enclosure include a mounting plate?

No, the mounting plate is not included for item numbers ending with PER5.

What are the dimensions of the MAS0604015PER5 enclosure?

The enclosure dimensions are 600x400x155mm, or 23.62 inches high, 15.75 inches wide, and 6.1 inches deep.

What is the color and finish of the enclosure?

The enclosure has a RAL 7035 structured powder coating in a light gray color.

What is the weight of the MAS0604015PER5 enclosure?

The enclosure weighs 22.9lb.

How does the enclosure facilitate wall fixing and air circulation?

It has four 8.5 mm diameter holes for wall fixing, pressed out in 20.4 mm diameter depressions to allow air circulation.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.