Overview

The nVent InLine Hinged Window Cover (SKU: LWC206015SS) offers a robust and aesthetically pleasing solution for protecting sensitive electrical and electronic components in demanding industrial environments. Engineered with a premium brushed Stainless 304 construction, this enclosure meets the rigorous NEMA Type 4X rating, ensuring superior protection against water, dust, and corrosion, making it ideal for washdown applications and outdoor installations. The InLine Series is renowned for its blend of sophisticated design and uncompromising functionality. This specific model, measuring 200x600x150mm, features a hinged window door that provides convenient access for inspection and maintenance while allowing visual monitoring of internal equipment. The outward-formed body flange is a critical design element, effectively preventing contaminants from entering the enclosure, thereby safeguarding the integrity of the housed devices. This attention to detail is paramount in industries where equipment reliability is non-negotiable. When selecting an enclosure, professionals prioritize durability, environmental resistance, and ease of access. The nVent LWC206015SS excels in all these areas. Its stainless steel construction offers exceptional resistance to a wide range of chemicals and harsh atmospheric conditions, a key consideration for sectors such as food and beverage processing, chemical manufacturing, and wastewater treatment. The brushed finish not only enhances its visual appeal but also contributes to its resistance to fingerprints and minor abrasions, maintaining a professional appearance over time. Key features of the nVent InLine Hinged Window Cover include: * **Premium Material:** Constructed from high-grade Stainless 304 for superior corrosion resistance and longevity. * **NEMA Type 4X Rating:** Guarantees protection against water ingress, dust, and corrosion, suitable for wet and corrosive environments. * **Hinged Window Door:** Facilitates easy access for visual inspection and maintenance, with a clear window for monitoring. * **Contaminant Prevention:** Outward-formed body flange design effectively seals out external elements. * **Aesthetic Appeal:** Brushed finish and flush latches contribute to a clean, modern look, suitable for visible installations. This enclosure is a testament to nVent's commitment to providing high-quality, reliable solutions for critical infrastructure. Whether used in manufacturing plants, outdoor control stations, or specialized processing facilities, the InLine Hinged Window Cover ensures that vital equipment remains protected and operational. Its thoughtful design, including flush latches that maintain the enclosure's sleek profile, underscores its suitability for applications where both performance and appearance matter. Professionals trust nVent for enclosures that deliver on their promises of protection and durability, even in the most challenging operational settings.
  • Seams continuously welded and ground smooth
  • External formed body flange trough
  • Large perimeter body opening
  • Fastening holes in back of body for direct mounting or optional external mounting brackets
  • Seamless foam-in-place gasket
  • M6 bonding provision on cover, M6 ground stud in body
  • Furnished hardware kit includes panel mounting screws, grounding hardware and sealing washers for wall-mounting holes
  • Furnished hardware kit includes panel mounting screws, grounding hardware and sealing washers for wall-mounting holes

Specifications

Application
Controls and Drives;Corrosive Environments;Hygienic Environments
Application
Hygienic Environments; Corrosive Environments; Controls and Drives
Body Thickness
1.98 mm
Body Thickness
14 ga
Body Thickness
16 ga
Color
Brushed
Color
Unpainted
Conductive Panel
LP2060G
Depth
150 mm
Depth
5.91 in
Door Thickness
14 ga
Door Thickness
1.59 mm
Door Thickness
16 ga
Finish
Brushed #4
Height
7.87
Height
200
Height
200 mm
IP Rating
IP66
Material
Stainless 304
Material
Stainless Steel;Stainless Steel 304
Material
Stainless Steel 304
Modification Services
Yes
Mounting
Wall Mounting Brackets Available
Mounting
7.15 x 21.08 in
NEMA Rating
4X Watertight, corrosion-resistant
Nema Rating
Type 4X
NEMA Rating
4X
Panel Size
181 x 581 mm
Panel Size
7.13 x 22.87 in
Product Family
InLine
Protection Rating
NEMA Type 12
Series
InLine
Size
200x600x150mm
Stainless Steel Type
304
Steel Panel
LP2060
Type
Stainless Steel Wall Mounted Industrial Enclosures
Type
Hazardous Location Enclosures
Type Number
Type 4X
Weight
14.5 lb
Width
23.62 in
Width
600 mm
Window Size
4.53 x 21.61 in
Window Size
343 x 366 mm
Package Dimensions (L x W x H)
13.5 IN x 11 IN x 8.5 IN
Package Dimensions (L x W x H)
34.29 cm x 27.94 cm x 21.59 cm
Package Weight (Imperial)
14.500 L
Package Weight (Metric)
6.577 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the LWC206015SS Controller

This guide provides step-by-step instructions for mounting and wiring the LWC206015SS Controller securely.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the LWC206015SS Controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Use terminal connectors to connect the power and signal wires to the appropriate terminals on the controller. Ensure all connections are tight and secure.

  3. Verify the installation

    Use a multimeter to check the voltage at the controller terminals to ensure proper power supply. Confirm that all connections are correct before powering on the device.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.