Authorized nVent Distributor
nVent LHC252015SS6 - InLine Hinged Cover 1/4 Turn Latch Type 4X, 250x200x150mm, Brushed, Stainless 316

nVent LHC252015SS6 InLine Hinged Cover 1/4 Turn Latch Type 4X, 250x200x150mm, Brushed, Stainless 316

UPC: 783510877606


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent InLine Hinged Cover (SKU: LHC252015SS6) is a Type 4X stainless steel enclosure designed for harsh industrial environments. Constructed from 316 stainless steel with a brushed finish, this enclosure resists corrosion, dust, and water ingress while maintaining a professional appearance. The 1/4-turn latch system enables quick access for maintenance or inspection, reducing downtime in critical applications. Key specifications include a 250x200x150mm footprint, continuous seam welding with ground smooth seams, and an outward-formed body flange to prevent contaminant entry. The enclosure features a large perimeter body opening for cable management and fastening holes for secure mounting. Its Type 4X rating ensures suitability for outdoor and corrosive environments, including chemical processing, water treatment, food and beverage, pharmaceuticals, and marine applications. Compatible with nVent’s InLine series, this enclosure integrates seamlessly into industrial control panels, sensor housings, and instrumentation enclosures. The brushed stainless steel finish provides both durability and aesthetic appeal, making it ideal for applications where both performance and visual consistency are required.
  • Seams continuously welded and ground smooth
  • External formed body flange trough
  • Large perimeter body opening
  • Fastening holes in back of body for direct mounting or optional external mounting brackets
  • Seamless foam-in-place gasket
  • M6 bonding provision on cover, M6 ground stud in body
  • Furnished hardware kit includes panel mounting screws, grounding hardware and sealing washers for wall-mounting holes
  • Furnished hardware kit includes panel mounting screws, grounding hardware and sealing washers for wall-mounting holes

Specifications

Application
Controls and Drives;Corrosive Environments;Hygienic Environments
Application
Corrosive Environments; Hygienic Environments; Controls and Drives
Body Thickness
14 ga
Body Thickness
16 ga
Body Thickness
1.98 mm
Color
Unpainted
Conductive Panel
LP2520G
Depth
5.91 in
Depth
150 mm
Door Thickness
14 ga
Door Thickness
16 ga
Door Thickness
1.59 mm
Finish
Brushed #4
Height
250 mm
Height
9.84 in
Height
250
Ip Rating
Type 4X
IP Rating
IP66
Material
Stainless 316
Material
Stainless Steel;Stainless Steel 316L
Material
Stainless Steel 316L
Modification Services
Yes
Mounting
Wall Mounting Brackets Available
Mounting
9.12 x 5.33 in
NEMA Rating
4X Watertight, corrosion-resistant
Nema Rating
Type 4X
NEMA Rating
4X
Panel Size
9.09 x 7.13 in
Panel Size
231 x 181 mm
Product Family
InLine
Protection Rating
NEMA Type 12
Size
250x200x150mm
Stainless Steel Type
316L
Steel Panel
LP2520
Type
Stainless Steel Wall Mounted Industrial Enclosures
Type
Hazardous Location Enclosures
Type Number
Type 4X
Weight
5 lb
Width
7.87 in
Width
200 mm
Package Dimensions (L x W x H)
10 IN x 8 IN x 6 IN
Package Dimensions (L x W x H)
25.4 cm x 20.32 cm x 15.24 cm
Package Weight (Imperial)
5.000 L
Package Weight (Metric)
2.268 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the LHC252015SS6 Wall-Mount Enclosure

Installation guide for mounting and wiring the LHC252015SS6 wall-mount enclosure.

Estimated time: 1h

Tools needed:

Drill, Level, Screwdriver, Wire strippers, Pliers, Measuring tape

Supplies needed:

Mounting hardware (screws, anchors), Wire connectors, Gasket material (if not pre-installed)

  1. Select Mounting Location

    Choose a suitable location for the enclosure. Ensure it is protected from extreme environmental conditions and provides adequate space for installation and maintenance. Refer to the datasheet for specific environmental ratings.

  2. Prepare the Enclosure

    If necessary, install the gasket material around the enclosure door. Identify the knockout locations for cable entry and exit. Remove the appropriate knockouts using a suitable tool.

  3. Mount the Enclosure

    Position the enclosure against the mounting surface. Use a level to ensure it is plumb. Mark the mounting hole locations. Drill pilot holes and install appropriate mounting hardware (screws, anchors) suitable for the mounting surface. Securely fasten the enclosure to the wall.

  4. Install Internal Components

    Mount any internal components such as backplates, subpanels, or mounting brackets according to their specific instructions. Ensure all components are securely fastened.

  5. Wire the Enclosure

    Route power and signal cables through the prepared knockouts. Use appropriate cable glands or conduit fittings to maintain environmental protection. Connect wiring to internal terminals or devices as per the wiring diagram. Ensure all connections are secure and properly insulated. Refer to the product's wiring diagram for specific connection details.

  6. Final Inspection and Sealing

    Verify all wiring connections are correct and secure. Ensure all knockouts are properly sealed with appropriate fittings or plugs. Close and latch the enclosure door, ensuring the gasket provides a proper seal.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.