Authorized nVent Distributor
nVent LHC151512SS6 - InLine Hinged Cover 1/4 Turn Latch Type 4X, 150x150x120mm, Brushed, Stainless 316

nVent LHC151512SS6 InLine Hinged Cover 1/4 Turn Latch Type 4X, 150x150x120mm, Brushed, Stainless 316

UPC: 783510877408


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent LHC151512SS6 InLine Hinged Cover Enclosure provides robust protection for electrical and electronic components. Constructed from Stainless Steel 316, it offers excellent corrosion resistance, suitable for environments exposed to moisture and chemicals. The brushed finish enhances durability and ease of maintenance. This enclosure features a Type 4X NEMA rating, ensuring protection against water ingress and dust, and is suitable for washdown applications. Its dimensions are 150x150x120mm, providing ample space for control panels and instrumentation. The hinged cover is secured with a 1/4 turn latch for quick access. The outward-formed body flange prevents contaminants from entering when the door is opened. This enclosure is ideal for food and beverage processing, chemical plants, and wastewater treatment facilities.
  • Seams continuously welded and ground smooth
  • External formed body flange trough
  • Large perimeter body opening
  • Fastening holes in back of body for direct mounting or optional external mounting brackets
  • Seamless foam-in-place gasket
  • M6 bonding provision on cover, M6 ground stud in body
  • Furnished hardware kit includes panel mounting screws, grounding hardware and sealing washers for wall-mounting holes
  • Furnished hardware kit includes panel mounting screws, grounding hardware and sealing washers for wall-mounting holes

Specifications

Application
Corrosive Environments; Controls and Drives; Hygienic Environments
Application
Controls and Drives;Corrosive Environments;Hygienic Environments
Body Thickness
16 ga
Body Thickness
14 ga
Body Thickness
1.98 mm
Color
Unpainted
Color
Brushed
Conductive Panel
LP1515G
Depth
120 mm
Depth
4.72 in
Depth
120
Door Thickness
1.59 mm
Door Thickness
14 ga
Door Thickness
16 ga
Finish
Brushed #4
Height
5.91 in
Height
150 mm
IP Rating
IP66
Material
Stainless Steel;Stainless Steel 316L
Material
Stainless Steel 316L
Material
Stainless Steel 316
Modification Services
Yes
Mounting
Wall Mounting Brackets Available
Mounting
5.18 x 3.36 in
NEMA Rating
4X Watertight, corrosion-resistant
Nema Rating
Type 4X
NEMA Rating
4X
Panel Size
5.16 x 5.16 in
Panel Size
131 x 131 mm
Product Family
InLine
Protection Rating
NEMA Type 12
Size
150x150x120mm
Size
150x150x120 mm
Stainless Steel Type
316L
Steel Panel
LP1515
Type
Stainless Steel Wall Mounted Industrial Enclosures
Type
Hazardous Location Enclosures
Type Number
Type 4X
Weight
3.96 lb
Width
5.91 in
Width
150 mm
Package Dimensions (L x W x H)
6.5 IN x 6.25 IN x 5.5 IN
Package Dimensions (L x W x H)
16.51 cm x 15.875 cm x 13.97 cm
Package Weight (Imperial)
3.960 L
Package Weight (Metric)
1.796 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the LHC151512SS6 Controller

This guide provides step-by-step instructions for installing and configuring the LHC151512SS6 Controller on a DIN rail.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the LHC151512SS6 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Using terminal connectors, connect the power supply wires to the designated input terminals on the controller. Verify that the connections are secure and correctly polarized.

  3. Configure the controller settings

    Power on the controller and use the interface to set the desired operational parameters. Refer to the user manual for specific configuration options.

  4. Calibrate the controller

    Perform a calibration of the controller by following the calibration procedure outlined in the user manual. Ensure all readings are within acceptable ranges.

  5. Test the installation

    Use a multimeter to verify that the output signals from the controller are functioning as expected. Check for proper voltage and current levels.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.