The nVent HyShed Hinge Cover Enclosure (SKU: HSDH363012SS) is a Type 4X stainless steel enclosure designed for sanitary washdown environments in food/beverage processing, pharmaceuticals, and meat/dairy facilities. Constructed from 304 stainless steel with a brushed finish, it resists corrosion and withstands high-pressure/temperature cleaning cycles. The 15-degree sloped top prevents liquid pooling and maximizes back panel space. Features an FDA-grade silicone gasket for bacteria and chemical resistance, with easy replacement. Meets NSF/ANSI 3-A and FDA requirements for direct/indirect food contact. Dimensions: 36" x 30" x 12". IP66 and IEC 60529 rated for dust and water jet protection. Compatible with optional inner panels (e.g., EN4SD363012SSWH) and accessories like DIN rail kits, door stop kits, and drip shield kits. Supports door swing reversal (EHLLSAK) and includes a door alignment guide for 36" models.
  • Brushed #4 finish for dairy applications
  • 15-degree sloped top facilitates runoff of water and cleaning solutions; prevents fluids or particulates from pooling
  • Door edges are sloped to facilitate runoff
  • Replaceable FDA-grade silicone gasket compliant with FDA Guideline 21 CFR 177.2600
  • Gasket is sanitary Pantone 287 blue color for easy detection by common food scanning equipment and vision systems
  • Internally mounted hinges to reduce bacteria-harboring catch points
  • Stainless steel crevice-free latch surfaces to reduce bacteria harboring catch points; uses standard tool to open
  • Solid back with no pre-tapped mounting holes for easy weld mounting; optional IP69K sanitary stand-off kit available
  • 105-degree door opening
  • Self-grounding latch system with double seal

Specifications

Application
Hygienic Environments; Corrosive Environments
Application
Corrosive Environments;Hygienic Environments
Color
Brushed stainless steel
Color
Unpainted
Conductive Panel
A36P30G
Depth
12
Depth
305 mm
Finish
#4 Dairy
Height
36 in
Height
914 mm
IP Rating
IP66
Ip Rating
IP4X
Latch Quantity
5
Material
304 Stainless Steel
Material
Stainless Steel 304
Material Quality
Stainless Steel 304
Material Quality
Stainless steel V2A
NEMA Rating
12 Indoor, dust-resistant
NEMA Rating
12
Nema Rating
Type 4X
Panel
A36P30
Product Family
HyShed
Protection Rating
NEMA Type 12
Replacement Gasket
HSDH3630GSK
Series
HyShed Hinge Cover Enclosures
Series
HyShed
Size
36.00x30.00x12.00 inches
Size
36.00x30.00x12.00
Size
36" x 30" x 12"
Stainless Steel Panel
A36P30SS6
Thickness
1.98 mm
Thickness
14 ga
Thickness
51.40mm (2.024")
Type
Stainless Steel Wall Mounted Industrial Enclosures
Weight
112 lb
Width
762 mm
Width
30 IN
Package Dimensions (L x W x H)
44.5 IN x 31 IN x 14.7 IN
Package Dimensions (L x W x H)
113.03 cm x 78.74 cm x 37.338 cm
Package Weight (Imperial)
112.000 L
Package Weight (Metric)
50.803 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the HSDH363012SS Enclosure

This guide provides step-by-step instructions for properly mounting and configuring the HSDH363012SS enclosure to ensure safe and effective operation.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the enclosure

    Secure the enclosure to the wall or surface using the appropriate mounting screws. Ensure the enclosure is level and plumb to guarantee proper sealing of the door.

  2. Seal the perimeter

    If mounted directly to a surface, apply sealant around the entire perimeter of the enclosure to prevent liquid ingress. Ensure the seal is continuous and meets 3-A requirements.

  3. Access the interior

    Loosen the cover screws and remove the cover to access the interior of the enclosure. Ensure the gasket is fully seated before reattaching the cover.

  4. Connect wiring

    Use wire strippers to prepare the wires for connection. Connect the wires to the terminal connectors inside the enclosure, ensuring all connections are secure.

  5. Verify connections

    Use a multimeter to check all electrical connections for continuity and proper voltage levels before energizing the circuits.

  6. Calibrate the enclosure

    Once all connections are verified, power on the enclosure and perform any necessary calibration as per the manufacturer's specifications.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.