nVent HJ606HWLG - Flat Cover Hinged with Screws Type 4X, 5.71x5.72x4.05, Light Gray, Fiberglass
nVent

HJ606HWLG

UPC: 783510158750


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent HJ606HWLG is a Type 4X fiberglass hinged enclosure designed for harsh industrial environments. This compression-molded fiberglass enclosure measures 5.71 x 5.72 x 4.05 inches (145 x 145 x 103 mm) and features a light gray (RAL 7035) finish inside and out. It meets multiple protection standards including NEMA/EEMAC Type 3, 3R, 4, 4X, 12, 13, CSA File No. 217184, IEC 60529 IP66, and NEMA Type 3RX for enhanced corrosion resistance. The enclosure's overlapping flat cover design with screw fasteners ensures a secure seal against dust, dirt, water ingress, and corrosive agents. It includes Type 304 stainless steel piano hinges for durability and corrosion resistance, allowing easy access to internal components without complete cover removal. Integral mounting brackets simplify installation. This halogen-free fiberglass enclosure protects sensitive equipment in water treatment, chemical processing, food and beverage production, and other industrial settings where environmental protection is critical. Optional accessories include vent drains, non-metallic hole seals, panels for junction boxes, swing-out panel kits, and terminal block kits for customization. nVent offers modification and customization services to meet unique project requirements.
  • Compression-molded fiberglass construction for superior strength and chemical resistance
  • Type 4X enclosure meets NEMA/EEMAC Type 3, 3R, 4, 4X, 12, 13; CSA File No. 217184; IEC 60529 IP66; NEMA Type 3RX
  • Overlapping flat cover with screw fasteners for secure sealing against dust, water, and corrosive agents
  • Type 304 stainless steel piano hinges for durable, corrosion-resistant access to internal components
  • Halogen-free material for enhanced safety in fire-prone environments
  • Enclosures protect equipment and operators from indirect electrical contact

Specifications

Aluminum Panel
A6P6AL
Application
Controls and Drives; Corrosive Environments
Color
Light Gray
Color Code
RAL 7035
Depth
4.05
Depth
103
Door Fasteners
Hinged, 2 screws
Finish
Smooth Matte
Height
5.71
Height
145
IP Rating
IP66
Material
Fiberglass
Modification Services
Yes
Mounting Type
Integral Mounting Brackets
Nema Rating
Type 4X
NEMA Rating
4X Watertight, corrosion-resistant
Panel Size
4.88 x 4.88 in
Product Family
HJ
Protection Rating
NEMA Type 12
Size
7.31x7.31x4.96 in
Size
5.71x5.72x4.05
Size
5.71x5.72x4.05 inches (145 x 145 x 103 mm)
Steel Panel
A6P6
Thickness
0.14 in
Type
Fiberglass and Thermoplastic Wall Mounted Industrial Enclosures
Weight
2.8 lb
Width
5.72
Width
145
Package Dimensions (L x W x H)
7.9 IN x 7.8 IN x 5.9 IN
Package Dimensions (L x W x H)
20.066 cm x 19.812 cm x 14.986 cm
Package Weight (Imperial)
2.800 L
Package Weight (Metric)
1.270 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the HJ606HWLG Controller

This guide provides step-by-step instructions for installing and configuring the HJ606HWLG Controller, ensuring proper wiring and setup.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Prepare the installation site

    Identify the location for the HJ606HWLG Controller installation and ensure the area is clean and free from obstructions.

  2. Mount the controller

    Secure the HJ606HWLG Controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  3. Connect the wiring

    Use terminal connectors to connect the power and signal wires to the controller. Ensure all connections are tight and secure to prevent electrical issues.

  4. Ground the controller

    Install the grounding conductor according to the National Electrical Code. Ensure proper bonding between grounding bushings and the equipment grounding terminal.

  5. Verify connections

    Use a multimeter to check all electrical connections for continuity and proper voltage levels before powering on the controller.

  6. Power on the controller

    Turn on the power supply to the HJ606HWLG Controller and observe the initial startup sequence for any errors.

  7. Configure the controller settings

    Access the controller's configuration interface to set parameters according to your specific application requirements.

  8. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure accurate operation of the HJ606HWLG Controller.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.