nVent HJ1614HWLG - Flat Cover Hinged with Screws Type 4X, 15.81x13.81x5.99, Light Gray, Fiberglass
nVent

HJ1614HWLG

UPC: 783510158828


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent HJ1614HWLG is a Type 4X fiberglass hinged enclosure designed for industrial environments requiring superior environmental protection. Constructed from compression-molded fiberglass, this enclosure resists corrosion, chemicals, and impact while maintaining structural integrity. Its overlapping flat cover, secured with screws and featuring Type 304 stainless steel piano hinges, ensures a tight seal against dust, water, and hose-directed ingress per NEMA Type 4X, 12, and 13 standards, as well as IEC 60529 IP66/IP67 ratings. The halogen-free material meets UL 508A and cUL Listed requirements, providing safety for indirect electrical contact scenarios. Key specifications include dimensions of 15.81" (H) x 13.81" (W) x 5.99" (D) with a standard RAL 7035 light-gray finish inside and out. Optional panel materials include white-painted steel, unpainted stainless steel, aluminum, conductive, or composite panels for customization. Integral mounting brackets simplify installation, while the hinged design allows convenient access for maintenance and equipment installation. Applications span chemical processing, food and beverage, water/wastewater treatment, and other industries where robust protection against harsh conditions is critical. Optional accessories include Type 4X vent drains, non-metallic hole seals, swing-out panel kits, and terminal block assemblies.
  • Type 4X/12/13 and IP66/IP67 rated for dust, water, and hose-directed ingress protection
  • Compression-molded fiberglass construction resists corrosion, chemicals, and impact
  • Hinged cover with stainless steel piano hinges and screw-secured overlapping flat design
  • Dimensions: 15.81" x 13.81" x 5.99" with RAL 7035 light-gray finish
  • UL 508A Listed and cUL Listed; halogen-free material
  • Enclosures protect equipment and operators from indirect electrical contact

Specifications

Aluminum Panel
A16P14AL
Application
Controls and Drives; Corrosive Environments
Color
Light Gray
Color Code
RAL 7035
Depth
5.99
Depth
152
Door Fasteners
Hinged, 2 screws
Finish
Smooth Matte
Height
15.81
Height
402
IP Rating
IP66
Ip Rating
IP4X
Ip Rating
IP66/IP67
Material
Fiberglass
Modification Services
Yes
NEMA Rating
4X Watertight, corrosion-resistant
Nema Rating
Type 4X
Panel Size
14.75 x 12.88 in
Product Family
HJ
Protection Rating
NEMA Type 12
Series
nVent Type 4X Fiberglass Hinged Flat Cover Enclosure
Size
17.31x15.30x6.70 in
Size
15.81x13.81x5.99
Size
15.81x13.81x5.99 inches
Steel Panel
A16P14
Thickness
0.14 in
Type
Fiberglass and Thermoplastic Wall Mounted Industrial Enclosures
Weight
10.2 lb
Width
13.81
Width
351
Package Dimensions (L x W x H)
17.8 IN x 15.8 IN x 7.7 IN
Package Dimensions (L x W x H)
45.212 cm x 40.132 cm x 19.558 cm
Package Weight (Imperial)
10.200 L
Package Weight (Metric)
4.627 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the HJ1614HWLG Controller

This guide provides step-by-step instructions for installing and configuring the HJ1614HWLG controller, including wiring and initial setup.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the HJ1614HWLG controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the conduit

    Cut holes in the enclosure as needed for conduit entry. Secure the conduit connector (hub) onto the conduit and attach it to the enclosure using the connector locknut.

  3. Ground the equipment

    Install the grounding conductor according to the National Electrical Code. Ensure proper bonding between grounding bushings and the equipment grounding terminal.

  4. Wiring connections

    Connect the necessary wires to the terminal connectors on the controller. Use wire strippers to prepare the wire ends and ensure secure connections.

  5. Verify connections

    Use a multimeter to check all connections for continuity and proper voltage levels before powering on the controller.

  6. Power on the controller

    Once all connections are verified, power on the HJ1614HWLG controller and observe the startup sequence for any errors.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.