Authorized nVent Distributor
nVent HDP5CN - InterSafe Data Interface Port for ControlNet, Duplex, Black, Steel

nVent HDP5CN InterSafe Data Interface Port for ControlNet, Duplex, Black, Steel

UPC: 783510149345


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent HDP5CN InterSafe Data Interface Port (SKU: HDP5CN) provides secure, external access for programming and diagnostics to industrial control systems utilizing ControlNet protocols. It features a duplex RJ45 receptacle as the primary connector and a 10-ft. shielded cable with a male RJ45 connector for secondary termination. This design allows technicians to connect to devices within enclosures without opening the door, significantly enhancing safety by preventing accidental contact with energized components and minimizing operational downtime. The HDP5CN is compatible with devices from leading manufacturers such as Allen-Bradley. An integrated 5-amp circuit breaker offers additional protection for connected equipment. nVent offers modifications and customization for this product series to meet specific application needs. Trust nVent for reliable electrical enclosure solutions.
  • Steel and Stainless Steel doors are welded and ground
  • Back plate is aluminum
  • All standard configurations include a GFCI or standard duplex receptacle with a 5-A circuit breaker for added safety
  • Door gasket (between the door and plate assemblies) and plate gasket (between the plate assembly and the enclosure) together provide a tight seal
  • Template provided for accurate enclosure cutout dimensions
  • Quarter-turn latch with screwdriver slot and padlock hasp on all steel and stainless steel door models for convenience and security
  • Quarter-turn latch with screwdriver slot on polycarbonate models

Specifications

Accessory Type
InterSafe Data Interface Ports
Application
Arc Flash Safety;Controls and Drives
Color
Black
Configuration
120 VAC Duplex Receptacle
Configuration
- 120 VAC duplex receptacle- Shielded RJ45- 5-amp circuit breaker
Configuration 1
Shielded RJ45
Finish
Alum/Black;Powder Coat
Finish
Powder Coated
IP Rating
IP66
Material
Mild Steel
Material
Mild Steel;Steel
Modification Services
Yes
Primary Connector Termination
- Shielded RJ45- 10-ft. shielded cable with male RJ45
Product Family
InterSafe
Size
143x176x24mm
Supports Devices Sold By
Allen-Bradley
Thickness
51.40mm (2.024")
Thickness
16 ga
Thickness
1.5 mm
Type
Electrical Accessories
Type Number
Type 4
Weight
3.1 lb
Works With
NEMA / IEC
Package Dimensions (L x W x H)
9.1 IN x 9 IN x 7.2 IN
Package Dimensions (L x W x H)
23.114 cm x 22.86 cm x 18.288 cm
Package Weight (Imperial)
3.100 L
Package Weight (Metric)
1.406 kg
The NE1.5X4WH6 Halogen-Free Wide Slot Wiring Duct design provides greater rigidity and allows for a wide range of wire/bundle sizes. Upper and lower scorelines for easy finger/sidewall section removal. UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95 C (203 F). Halogen-Free, Polyphenylene Oxide (PPO). Mounting holes provided. 4.06" x 1.64" (103.1 mm x 41.7 mm) and 6' (1.83 m) long. Cover sold separately. Color White. 6 pieces per package.

NE1.5X4WH6

The NE1.5X4WH6 Halogen-Free Wide Slot Wiring Duct design provides greater rigidity and allows for a wide range of wire/bundle sizes. Upper and lower scorelines for easy finger/sidewall section removal. UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95 C (203 F). Halogen-Free, Polyphenylene Oxide (PPO). Mounting holes provided. 4.06" x 1.64" (103.1 mm x 41.7 mm) and 6' (1.83 m) long. Cover sold separately. Color White. 6 pieces per package.
The NNC75X75WH2 Halogen-Free Wide Slot Wiring Duct is used to route, protect, and manage wires near sensitive electronic equipment and in environments where heat resistance or public safety is a concern. UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95 C (203 F). Halogen-Free, Polyphenylene Oxide (PPO). Mounting holes provided. 2.85" x 2.97" (72.4 mm x 75.4 mm) and 6.6' (2 m) long. Cover included. Color White. 5 pieces per package.

NNC75X75WH2

The NNC75X75WH2 Halogen-Free Wide Slot Wiring Duct is used to route, protect, and manage wires near sensitive electronic equipment and in environments where heat resistance or public safety is a concern. UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95 C (203 F). Halogen-Free, Polyphenylene Oxide (PPO). Mounting holes provided. 2.85" x 2.97" (72.4 mm x 75.4 mm) and 6.6' (2 m) long. Cover included. Color White. 5 pieces per package.
2 x 3 Inches Duct Spacer, High Impact Polystyrene Snap-Loc Intermediate Spacer For Use With Nonmetallic Ducts

S289JLN

2 x 3 Inches Duct Spacer, High Impact Polystyrene Snap-Loc Intermediate Spacer For Use With Nonmetallic Ducts
2 x 3 Inches Duct Spacer, High Impact Polystyrene Snap-Loc Base Spacer For Use With Nonmetallic Ducts

S288JLN

2 x 3 Inches Duct Spacer, High Impact Polystyrene Snap-Loc Base Spacer For Use With Nonmetallic Ducts

How to Install the HDP5CN Enclosure

Installation guide for mounting the HDP5CN enclosure. Verify dimensions and clearances before drilling or installation.

Estimated time: 1h

Tools needed:

Drill, Level, Measuring tape

Supplies needed:

Mounting hardware (screws, bolts, etc.), Sealing material (if required)

  1. Verify Dimensions and Clearances

    Before proceeding with installation, carefully verify all dimensions and required clearances for the HDP5CN enclosure. Ensure the intended mounting location can accommodate the enclosure's size (166mm x 160mm / 6.54 x 6.30) and any necessary surrounding space.

  2. Prepare Mounting Location

    Mark the enclosure's mounting points on the installation surface based on the verified dimensions. Ensure the surface is clean, stable, and capable of supporting the weight of the enclosure and its contents. If drilling is required, use appropriate drill bits for the mounting surface material.

  3. Mount the Enclosure

    Position the HDP5CN enclosure against the prepared mounting surface, aligning the mounting points. Secure the enclosure using appropriate mounting hardware. Ensure the enclosure is level and firmly attached. If necessary, apply sealing material around the mounting points to maintain environmental protection.

  4. Final Check

    Once mounted, double-check that the enclosure is securely fastened and level. Inspect any seals or gaskets to ensure they are properly seated for environmental protection.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.