Contact for Pricing
Overview
- Gland plates provide easily customizable cable egress for internal components
- Gland plates are easy to replace as installation modifications are completed after initial install
- NEMA 4X and IP66 ingress protection ratings
- Integrated ground connection for enhanced safety
- Certified for hazardous locations (Zone 1 or 2)
Specifications
Application | Hazardous Environments |
Cable Entry | 7.50 x 5.75 in Cutout Size |
Color | Unpainted |
Cutout Size | 7.50 x 5.75 in |
Cutout Size | 18.69 x 7.19 in |
Dimensions | 28W x 10D x 10H IN |
Dimensions | 8.98 x 7.23 in |
Finish | Brushed |
Height | 44 IN |
Height | 7.23 in |
IP Rating | IP66 |
Material | Type 316 Stainless Steel |
Material | SS Type 316 |
Material | Stainless Steel |
Material | SS Type 316;Stainless Steel 316L |
Modification Services | No |
Mounting Type | Surface Mounting |
Nema Rating | NEMA 12, 4, 4X |
Nema Rating | NEMA 4X |
Product Family | Zonex |
Series | EXE SG Gland Plate |
Series | nVent HOFFMAN |
Size | 8.98 x 7.23 in |
Size | 12 in. x 8 in. |
Thickness | 51.40mm (2.024") |
Thickness | 12 ga |
Type | External Mounting for Industrial Enclosures |
Weight | 2.14 lb |
Width | 23 IN |
Width | 8.98 in |
Works With | NEMA / IEC |
Package Dimensions (L x W x H) | 13 IN x 10 IN x 2 IN |
Package Dimensions (L x W x H) | 33.02 cm x 25.4 cm x 5.08 cm |
Package Weight (Imperial) | 2.140 L |
Package Weight (Metric) | 0.971 kg |

82181T-1234-1CV
Telecommunication Box, 64 Cubic Inches, 5 Inches Square x 2-7/8 Inches Deep, 1/2 Inch, 3/4 Inch, and 1 Inch Knockouts, Pre-Galvanized Steel, with Cable Management Posts and CV BracketHow to Install the GPS128SS6 Controller
This guide provides step-by-step instructions for installing and configuring the GPS128SS6 Controller for optimal performance.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Wire connectors, Anti-seize compound
- Mount the controller
Secure the GPS128SS6 controller to the designated mounting surface using the provided mounting screws. Ensure the controller is level and firmly attached.
- Connect the wiring
Using wire strippers, prepare the wires for connection. Connect the power and signal wires to the appropriate terminals on the GPS128SS6 controller, ensuring a secure fit.
- Verify connections
Use a multimeter to check the voltage at the power terminals of the GPS128SS6 controller. Ensure that the voltage is within the specified range before proceeding.
- Configure the controller
Follow the manufacturer's instructions to access the configuration menu of the GPS128SS6 controller. Set the desired parameters for operation.
- Calibrate the system
Perform any necessary calibration procedures as outlined in the user manual to ensure the GPS128SS6 controller operates accurately.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.