- Gland plates provide easily customizable cable egress for internal components
- Gland plates are easy to replace as installation modifications are completed after initial install
- UL Type 4, 4X, and 12 certified for indoor/outdoor use
- Compatible with 30-inch wide, 12-inch deep standard enclosure bottoms
- Certified for Division 1/2 and Zone 1/2 hazardous locations (ATEX/IECEx)
Specifications
Application | Hazardous Environments |
Cable Entry | 21.50 x 7.00 in Cutout Size |
Color | Unpainted |
Cutout Size | 21.50 x 7.00 in |
Cutout Size | 18.69 x 7.19 in |
Dimensions | 28W x 10D x 10H IN |
Dimensions | 21.49 x 8.48 in |
Finish | Brushed |
Height | 44 IN |
Height | 8.48 in |
Ip Rating | IP66/IP67 |
Material | SS Type 316 Stainless Steel |
Material | SS Type 316;Stainless Steel 316L |
Material | Stainless Steel |
Modification Services | No |
Mounting Type | Surface Mount |
Product Family | Zonex |
Series | nVent |
Size | 21.49 x 8.48 in |
Size | 24 in. x 12 in. |
Thickness | 51.40mm (2.024") |
Thickness | 12 ga |
Type | External Mounting for Industrial Enclosures |
Weight | 6.1 lb |
Width | 21.49 in |
Width | 23 IN |
Works With | NEMA / IEC |
Package Dimensions (L x W x H) | 23.5 IN x 9.3 IN x 1.9 IN |
Package Dimensions (L x W x H) | 59.69 cm x 23.622 cm x 4.826 cm |
Package Weight (Imperial) | 6.100 L |
Package Weight (Metric) | 2.767 kg |

52171-CM13
Pre-Fabricated, Single Gang Outlet Box, 30.3 Cubic Inches, 4 Inch Square x 2-1/8 Inch Deep x 1/2 Inch Raised, 1/2 Inch and 3/4 Inch Eccentric Knockouts, Galvanized Steel, with Box Support Cover, 10-1/2 Inch #12 AWG Solid Ground Wire Pigtail, For use with ConduitFrequently Asked Questions
What are the dimensions of the GP2412SS6 gland plate?
The GP2412SS6 has overall dimensions of 22.98 x 8.48 inches with a cutout size of 21.50 x 7.00 inches.
What temperature range does the GP2412SS6 support?
The GP2412SS6 operates reliably within a service temperature range of -50°C to +100°C.
What certifications does the GP2412SS6 have?
The GP2412SS6 is certified for Division 1/2 and Zone 1/2 hazardous locations, meeting ATEX and IECEx standards (Ex e IIC Gb, Ex tb IIIC Db).
What enclosure size is compatible with the GP2412SS6?
The GP2412SS6 is compatible with 30-inch wide, 12-inch deep standard enclosure bottoms.
Is the GP2412SS6 suitable for outdoor use?
Yes, the GP2412SS6 is UL Type 4 and 4X rated, making it suitable for outdoor and indoor applications.
How to Install the GP2412SS6 Controller
This guide provides step-by-step instructions for installing and configuring the GP2412SS6 controller on a DIN rail.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Mount the controller
Secure the GP2412SS6 controller to the DIN rail using the integrated clips. Ensure that the controller is level and firmly attached.
- Connect the power supply
Using the wire strippers, prepare the power supply wires and connect them to the appropriate terminals on the controller. Ensure that the connections are tight and secure.
- Verify connections
Use a multimeter to check the voltage at the power terminals of the controller to ensure proper voltage is supplied. Confirm that all connections are secure and correct.
- Configure the controller settings
Access the configuration menu of the GP2412SS6 controller and input the necessary parameters for your application. Follow the on-screen instructions to complete the setup.
- Calibrate the controller
Perform any required calibration procedures as per the manufacturer's guidelines to ensure accurate operation of the controller.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.