The nVent GP128SS6 is a 12-inch by 8-inch gland plate constructed from 14-gauge Type 316 stainless steel. This removable plate ensures a sealed interface for cable entry and egress into NEMA 4X enclosures, effectively protecting against dust, moisture, and corrosive elements. Certified for hazardous locations (Zone 1/2, ATEX, IECEx), it meets UL/CSA and IP66 standards. The GP128SS6 is ideal for harsh industrial environments such as chemical processing, food and beverage, and marine applications. Includes necessary hardware and a cutout template for straightforward installation.
  • Gland plates provide easily customizable cable egress for internal components
  • Gland plates are easy to replace as installation modifications are completed after initial install
  • Maintains NEMA 4X, UL/CSA, and IP66 enclosure integrity for hazardous locations.
  • Provides a sealed interface for cable entry and egress.
  • Includes hardware and cutout template for easy installation.

Specifications

Application
Hazardous Environments
Cable Entry
9.50 x 5.75 in Cutout Size
Color
Unpainted
Cutout Size
9.50 x 5.75 in
Cutout Size
18.69 x 7.19 in
Dimensions
28W x 10D x 10H IN
Dimensions
10.98 x 7.23 in
Finish
Brushed
Height
44 IN
Height
7.23 in
Ip Rating
IP not explicitly stated (implied by NEMA 4X)
Ip Rating
IP66/IP67
IP Rating
IP66
Material
Stainless Steel Type 316
Material
SS Type 316;Stainless Steel 316L
Material
Stainless Steel
Material
Type 316 Stainless Steel
Modification Services
No
Mounting Type
Enclosure Mounting
Mounting Type
Hardware Included
Nema Rating
Type 4X
NEMA Rating
Type 3R
Nema Rating
NEMA 4X
Product Family
Zonex
Series
nVent GP Series
Series
GP
Series
EXE Gland Plate
Series
nVent
Size
10.98 x 7.23 in
Size
12in x 8in
Size
12 in. x 8 in.
Thickness
12 ga
Thickness
51.40mm (2.024")
Type
External Mounting for Industrial Enclosures
Weight
2.5 lb
Width
10.98 in
Width
23 IN
Works With
NEMA / IEC
Package Dimensions (L x W x H)
13.5 IN x 10 IN x 1.5 IN
Package Dimensions (L x W x H)
34.29 cm x 25.4 cm x 3.81 cm
Package Weight (Imperial)
2.500 L
Package Weight (Metric)
1.134 kg
12 in. x 8 in. EXE SG Gland Plate, SS Type 316

GPS128SS6

12 in. x 8 in. EXE SG Gland Plate, SS Type 316
Telecommunication Box, 64 Cubic Inches, 5 Inches Square x 2-7/8 Inches Deep, 1 Inch Knockouts, Pre-Galvanized Steel, with Cable Management Posts

82181T-1

Telecommunication Box, 64 Cubic Inches, 5 Inches Square x 2-7/8 Inches Deep, 1 Inch Knockouts, Pre-Galvanized Steel, with Cable Management Posts
2 1/8" Deep Welded Box 4 11/16" Square

FA-411

2 1/8" Deep Welded Box 4 11/16" Square

Frequently Asked Questions

What material is the nVent GP128SS6 gland plate made from?

The nVent GP128SS6 gland plate is constructed from Type 316 stainless steel, offering excellent corrosion resistance.

Is the nVent GP128SS6 suitable for hazardous locations?

Yes, the nVent GP128SS6 is certified for hazardous locations, including Zone 1/2, ATEX, and IECEx.

What are the dimensions of the nVent GP128SS6 gland plate?

The nVent GP128SS6 gland plate measures 12 inches by 8 inches.

Does the gland plate include installation hardware?

Yes, the nVent GP128SS6 gland plate includes the necessary hardware and a cutout template for installation.

What NEMA and IP ratings does this gland plate meet?

This gland plate meets NEMA Type 3RX and IP66 ratings, ensuring protection against dust and water ingress.

How to Install the GP128SS6 Controller

This guide provides step-by-step instructions for mounting, wiring, and configuring the GP128SS6 Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the GP128SS6 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Use terminal connectors to connect the power supply wires to the designated input terminals on the controller. Ensure proper polarity is observed.

  3. Verify connections

    Use a multimeter to check the voltage at the input terminals to ensure the controller is receiving the correct power supply voltage.

  4. Configure the controller settings

    Access the configuration interface of the GP128SS6 and input the necessary parameters according to your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure the controller operates within the desired specifications.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.