Overview
- Feed-Through Box Connectors are used inside enclosure when wireway is connected to ensure a tight seal
- Connects to other wireway sections and fittings and protects wires and cables against dust in a broad range of industrial applications
- 0.12 in. (3 mm) gasket accommodation for dust-tight seal
- CSA certified for compatibility with wireway fittings (elbows, tees, swivel nipples)
- Ideal for manufacturing, chemical processing, and data center applications
Specifications
Application | Power Distribution |
Color | Gray |
Color | Grey |
Color Code | ANSI 61 |
Connection Type | Feed-Through |
Finish | Painted;Powder Coat |
Finish | Powder Coated |
Height | 44 IN |
Height | 8 in |
Height | 203.2 mm |
Height | 203 |
IP Rating | IP66 |
IP Rating | IP54 |
Material | Mild Steel |
Material | Mild Steel;Steel |
Material | Steel |
Modification Services | Yes |
Nema Rating | Type 12 |
NEMA Rating | 12 Indoor, dust-resistant |
NEMA Rating | 12 |
Protection Rating | NEMA Type 12 |
Series | F88WB |
Size | 8.00x8.00 inch |
Size | 8.00x8.00 inches |
Thickness | 51.40mm (2.024") |
Thickness | 1.9 mm |
Thickness | 14 ga |
Type | Box Connector |
Type | Box Connector;Industrial Feed-Through Wireway |
Weight | 1.6 lb |
Width | 203 |
Width | 8 in |
Width | 23 IN |
Wireway | Feed-Through NEMA Type 12 Wireway |
Package Dimensions (L x W x H) | 11.25 IN x 11.25 IN x 0.8 IN |
Package Dimensions (L x W x H) | 28.575 cm x 28.575 cm x 2.032 cm |
Package Weight (Imperial) | 1.600 L |
Package Weight (Metric) | 0.726 kg |

T702BIW10
Twin-70 raceway base, 10 foot length. Supplied with pre-punched mounting holes. 2' of cover needed for every 1' of Twin-70 base.Frequently Asked Questions
Is the F88WB CSA certified?
Yes, the F88WB is CSA certified for compliance with safety standards.
What wireway fittings are compatible with the F88WB?
The F88WB connects with 90° elbows, tees, swivel nipples, and other wireway sections.
What applications is the F88WB suitable for?
It is ideal for manufacturing plants, chemical processing facilities, and data centers.
What material is the F88WB made from?
The F88WB is constructed from durable steel.
What are the internal dimensions of the F88WB?
The internal dimensions are 8.00 x 8.00 inches (203 x 203 mm).
What is the external size of the F88WB?
The external dimensions are 9.62 x 9.62 inches (244 x 244 mm).
Does the F88WB support gasket sealing?
Yes, it accommodates a 0.12 inch (3 mm) gasket at joints for a secure dust-tight seal.
How to Install the Feed-Through Wireway
This guide provides step-by-step instructions for installing and configuring the Feed-Through Wireway, ensuring proper assembly and secure connections.
Estimated time: 1h
Tools needed:
Screwdriver, Drill, Wire strippers
Supplies needed:
Mounting screws, Gaskets, Terminal connectors, Cap nuts, Lockwashers
- Assemble the wireway sections
Place a gasket between the flanges of the wireway sections and secure them using screws and nuts as shown in the assembly details.
- Install the telescope fitting
Assemble the telescope fitting parts in the correct order, insert the body into the straight section, and adjust to the desired length. Ensure the gasket is properly positioned against the flange.
- Anchor the telescope fitting
Drill .25 inch diameter holes through the straight section and telescope fitting at the desired extension. Install .25−20x.5 screws from the outside and secure with cap nuts and lockwashers.
- Cut the wireway to length
Cut the wireway body to the desired length, ensuring a square cut. Weld an extra flange to the body and grind off any burrs or sharp edges.
- Install swivel nipples
Position the wireway section, flange gasket, swivel ring, and swivel nipple in order. Secure with clips, screws, and nuts as detailed in the installation instructions.
- Make box entries
For box entries without swivel nipples, cut out the necessary openings in the enclosure. Position the box connector and gasket inside the enclosure, ensuring proper alignment with the wireway.
- Assemble hangers
Assemble the hangers as shown in the details, ensuring they do not fit between adjacent wireway flanges. Attach them to the wireway flanges in various positions as needed.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.