The nVent F66WPSS is a 6.00x6.00 inch closure plate designed for Feed-Through Wireway systems. Constructed from durable Stainless Steel 304 with a brushed finish, this component from nVent effectively seals the end of a wireway section or run. It is engineered for environments that are regularly hosed down, very wet, or highly corrosive, meeting stringent NEMA Type 4X and 12, CSA Type 1, and IEC 60529 IP66 standards. The robust stainless steel construction provides excellent resistance to corrosion, making it ideal for demanding applications in food and beverage processing, pharmaceutical manufacturing, water treatment facilities, and marine environments. The F66WPSS is certified by the Canadian Standards Association. All dimensions are to outside surfaces, with an allowance for gasket at joints. SKU: F66WPSS. Country of Origin: US. The F66WPSS closure plate has dimensions of 7.62 inches (194 mm) in both D and E directions, measured to outside surfaces. An allowance of 0.12 inches (3 mm) is included for gasket at joints. This product is certified by the Canadian Standards Association.
  • Feed-Through Stainless Steel Closure Plates are used for closing the end of a wireway run
  • Connects to other wireway sections and fittings and protects wires and cables in frequently hosed down, very wet or highly corrosive applications
  • Meets NEMA Type 4X and 12, CSA Type 1, and IEC 60529 IP66 standards
  • Ideal for wet, hosed-down, or highly corrosive environments
  • Certified by the Canadian Standards Association

Specifications

Application
Corrosive Environments;Hygienic Environments;Power Distribution
Application
Corrosive Environments; Power Distribution; Hygienic Environments
Color
Brushed
Color
Unpainted
Finish
No. 2B
Height
44 IN
Height
6
Height
152
IP Rating
IP66
Material
Stainless Steel 304
Modification Services
Yes
NEMA Rating
4X
NEMA Rating
4X Watertight, corrosion-resistant
Protection Rating
NEMA Type 4X
Size
6.00x6.00
Thickness
1.59 mm
Thickness
16 ga
Thickness
51.40mm (2.024")
Type
Closure Plate
Type
Closure Plate;Industrial Feed-Through Wireway
Weight
2.6 lb
Width
6
Width
152
Width
23 IN
Wireway
Stainless Steel Feed-Through NEMA Type 4X Wireway
Package Dimensions (L x W x H)
12.2 IN x 10 IN x 1 IN
Package Dimensions (L x W x H)
30.988 cm x 25.4 cm x 2.54 cm
Package Weight (Imperial)
2.600 L
Package Weight (Metric)
1.179 kg
Nipple Feed-Through Wireway, 6.00x6.00x6.00, Brushed, Stainless Steel 304

F66WN6SS

Nipple Feed-Through Wireway, 6.00x6.00x6.00, Brushed, Stainless Steel 304
N4X Wireway, Drop Hanger - Fits 8 x 8 - 304SS

1487EL1SS

N4X Wireway, Drop Hanger - Fits 8 x 8 - 304SS
Wire Safe Fitting - 6 inch X 6 Inch External Coupling.

EGCER

Wire Safe Fitting - 6 inch X 6 Inch External Coupling.
Twin-70 raceway base, 10 foot length. Supplied with pre-punched mounting holes. 2' of cover needed for every 1' of Twin-70 base.

T702BIW10

Twin-70 raceway base, 10 foot length. Supplied with pre-punched mounting holes. 2' of cover needed for every 1' of Twin-70 base.

How to Install the Feed-Through Wireway

This guide provides step-by-step instructions for installing and configuring the Feed-Through Wireway, ensuring proper assembly and connection.

Estimated time: 1h

Tools needed:

Screwdriver, Drill, Wire strippers

Supplies needed:

Mounting screws, Gaskets, Nuts, Lockwashers, Threaded rods

  1. Assemble the wireway sections

    Place a gasket between the flanges of the wireway sections and secure them using screws and nuts as shown in the assembly details.

  2. Install the telescope fitting

    Assemble the telescope fitting parts in the correct order, insert it into the straight section, and adjust to the desired length. Ensure the gasket is properly positioned against the flange.

  3. Anchor the telescope fitting

    Drill .25 inch diameter holes through the straight section and telescope fitting. Install .25−20x.5 screws from the outside and secure with cap nuts and lockwashers.

  4. Cut the wireway to length

    Cut the wireway body to the desired length, ensuring it is cut squarely. Weld an extra flange to the body and grind off any sharp edges.

  5. Install swivel nipples

    Position the wireway section, flange gasket, swivel ring, and swivel nipple in order. Secure with clips, screws, and nuts.

  6. Make box entries

    Cut out the necessary openings in the enclosure for box entries. Position the box connector and gaskets inside the enclosure, ensuring proper alignment with the wireway.

  7. Assemble hangers

    Assemble the hangers according to the provided details, ensuring they are attached to the wireway flanges in the desired positions.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.