nVent F66WB - Box Connector Feed-Through, 6.00x6.00, Gray, Steel
nVent

F66WB

UPC: 783510145606


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent F66WB Box Connector Feed-Through (SKU: F66WB) is a robust steel component designed for secure wireway integration into industrial enclosures. Measuring 6.00x6.00 inches, this feed-through connector ensures a tight seal, maintaining the enclosure's protective rating. Its durable gray steel construction offers resistance to corrosion and mechanical stress, suitable for demanding industrial environments. The F66WB is engineered to provide IP66 protection against dust ingress and water jets, making it ideal for applications in manufacturing, oil and gas, and automation systems where environmental resilience is critical. It facilitates seamless wireway connections while preserving enclosure integrity. Key applications include control panel wireway integration, outdoor electrical installations, hazardous location cable management, and industrial automation wiring. Professionals rely on nVent for dependable solutions that meet industry standards. Selecting the F66WB ensures reliable performance and ease of installation for mission-critical applications.
  • Feed-Through Box Connectors are used inside enclosure when wireway is connected to ensure a tight seal
  • Connects to other wireway sections and fittings and protects wires and cables against dust in a broad range of industrial applications
  • IP66 rated for dust and water jet protection
  • Maintains enclosure's protective rating
  • Designed for industrial automation and control panels

Specifications

Application
Power Distribution
Color
Gray
Color Code
ANSI 61
Finish
Painted;Powder Coat
Finish
Powder Coated
Height
44 IN
Height
6
Height
152
IP Rating
IP54
Material
Mild Steel
Material
Mild Steel;Steel
Modification Services
Yes
NEMA Rating
12 Indoor, dust-resistant
NEMA Rating
12
Protection Rating
NEMA Type 12
Thickness
14 ga
Thickness
1.9 mm
Thickness
51.40mm (2.024")
Type
Box Connector
Type
Box Connector;Industrial Feed-Through Wireway
Weight
1.12 lb
Width
6
Width
152
Width
23 IN
Wireway
Feed-Through NEMA Type 12 Wireway
Package Dimensions (L x W x H)
12 IN x 10 IN x 0.3 IN
Package Dimensions (L x W x H)
30.48 cm x 25.4 cm x 0.762 cm
Package Weight (Imperial)
1.120 L
Package Weight (Metric)
0.508 kg
Closure Plate Feed-Through Wireway, 6.00x6.00, Gray, Mild Steel

F66WP

Closure Plate Feed-Through Wireway, 6.00x6.00, Gray, Mild Steel
N12 Wireway, Cut-Off Fitting, Lay-In - Fits 12 x 6 - Steel/Gray

1485FW1

N12 Wireway, Cut-Off Fitting, Lay-In - Fits 12 x 6 - Steel/Gray
Wire Safe Fitting - 6 inch X 6 Inch External Coupling.

EGCER

Wire Safe Fitting - 6 inch X 6 Inch External Coupling.
Twin-70 raceway base, 10 foot length. Supplied with pre-punched mounting holes. 2' of cover needed for every 1' of Twin-70 base.

T702BIW10

Twin-70 raceway base, 10 foot length. Supplied with pre-punched mounting holes. 2' of cover needed for every 1' of Twin-70 base.

How to Install the Feed-Through Wireway

This guide provides step-by-step instructions for installing and configuring the Feed-Through Wireway, ensuring proper assembly and connection.

Estimated time: 45m

Tools needed:

Screwdriver, Drill, Wire strippers

Supplies needed:

Mounting screws, Gaskets, Terminal connectors

  1. Assemble the wireway sections

    Place a gasket between the flanges of the wireway sections and secure them using screws and nuts as shown in the assembly details.

  2. Install the telescope fitting

    Assemble the telescope fitting parts in the correct order, insert the body into the straight section, and adjust to the desired length. Ensure the gasket is properly positioned and secure it with the compression ring and screws.

  3. Anchor the telescope fitting

    If the telescope fitting is used vertically, drill .25 inch diameter holes through the straight section and telescope fitting. Install .25−20x.5 screws from the outside and secure with cap nuts and lockwashers.

  4. Cut the wireway to length

    Cut the wireway body to the desired length, ensuring a square cut. Weld an extra flange to the body and grind off any burrs or sharp edges.

  5. Install the swivel nipple

    Position the wireway section, flange gasket, swivel ring, and swivel nipple in order. Secure the assembly using screws and nuts, ensuring all components are tightly fastened.

  6. Make box entries

    For box entries without a swivel nipple, cut out the necessary openings in the enclosure as shown in the details. Position the box connector and gasket inside the enclosure, and place another gasket between the wireway and the enclosure.

  7. Install hangers

    Assemble the hangers as shown in the details, ensuring they are attached to the wireway flanges in various positions as needed.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.