nVent F66LP - Closure Plate Hinged-Cover Lay-in Wireway, 6.00x6.00, Gray, Mild Steel
nVent

F66LP

UPC: 783510186708


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent F66LP (SKU: F66LP) is a 6.00 x 6.00 inch closure plate designed for nVent's NEMA Type 12 Lay-In Wireway systems. Manufactured from mild steel with a gray finish, this component serves to securely seal the end of a wireway section or run, preventing the ingress of dust and debris. Its hinged-cover design offers convenient access for installation, inspection, and maintenance. The F66LP is specifically engineered to maintain the lay-in feature of the wireway, simplifying wire entry and routing without requiring complex threading. This closure plate is ideal for applications in commercial buildings, industrial facilities, and data centers where reliable cable management and system integrity are paramount. Each sealing plate includes one gasket and one set of screws for joining sections. Certified by Canadian Standards Association. The F66LP closure plate has dimensions of 7.62 inches (194 mm) in depth and 7.62 inches (194 mm) in width, as indicated by the D and E measurements in the catalog. It is designed for use with 6.00 x 6.00 inch (152 x 152 mm) wireway sections.
  • Lay-in Hinged-Cover Closure Plates are used for closing and sealing the end of a wireway section or run
  • Hinged cover for easy access
  • Mild steel construction with gray finish
  • Maintains lay-in feature for simplified wire routing
  • Includes one gasket and one set of screws
  • Certified by Canadian Standards Association

Specifications

Application
Power Distribution
Color
Gray
Color Code
ANSI 61
Finish
Galvanized;Painted
Finish
Galvanized
Height
44 IN
Height
6
Height
152
IP Rating
IP54
Material
Mild Steel
Material
Mild Steel;Steel
Modification Services
Yes
NEMA Rating
12 Indoor, dust-resistant
NEMA Rating
12
Protection Rating
NEMA Type 12
Sealing Plate Quantity
1
Sealing Plate Type
90°
Sealing Plate Type
90°
Thickness
14 ga
Thickness
1.9 mm
Thickness
51.40mm (2.024")
Type
Closure Plate;Industrial Lay-in Wireway
Type
Closure Plate
Weight
2.98 lb
Width
23 IN
Width
6
Width
152
Wireway
Lay-In NEMA Type 12 Wireway
Package Dimensions (L x W x H)
12.2 IN x 10 IN x 1.3 IN
Package Dimensions (L x W x H)
30.988 cm x 25.4 cm x 3.302 cm
Package Weight (Imperial)
2.980 L
Package Weight (Metric)
1.352 kg
Nipple Lay-in Hinged-Cover, 6.00x6.00x1.00, Gray, Steel

F66LN1

Nipple Lay-in Hinged-Cover, 6.00x6.00x1.00, Gray, Steel
N12 Wireway, Cut-Off Fitting, Lay-In - Fits 12 x 6 - Steel/Gray

1485FW1

N12 Wireway, Cut-Off Fitting, Lay-In - Fits 12 x 6 - Steel/Gray
Wire Safe Fitting - 6 inch X 6 Inch External Coupling.

EGCER

Wire Safe Fitting - 6 inch X 6 Inch External Coupling.
Twin-70 raceway base, 10 foot length. Supplied with pre-punched mounting holes. 2' of cover needed for every 1' of Twin-70 base.

T702BIW10

Twin-70 raceway base, 10 foot length. Supplied with pre-punched mounting holes. 2' of cover needed for every 1' of Twin-70 base.

How to Install the F66LP Lay-In Wireway

This guide provides step-by-step instructions for installing and configuring the F66LP Lay-In Wireway, ensuring proper assembly and sealing for effective cable management.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Drill, Wrench

Supplies needed:

Mounting screws, Gaskets, Terminal connectors, 90° sealing plates

  1. Assemble the wireway sections

    Place a gasket between the flanges of the wireway sections and secure them using screws and nuts as shown in the installation details.

  2. Seal the joints

    For joints between lay-in sections, position the LSGQR fitting, leaving out the top flange screw on the hinge side. Install with a shoulder bolt through the flange and ensure gaskets are visible from above.

  3. Install box entries

    Make a cutout in the control enclosure for the wireway entry. Position the box connector and gasket inside the enclosure, then install a 90° sealing plate between the wireway section and the enclosure.

  4. Adjust telescope fitting

    Assemble the compression ring, gasket, and retainer on the telescope fitting body. Insert the body into the straight section and adjust to the desired length, ensuring the gasket is properly seated.

  5. Anchor the telescope fitting

    If the telescope fitting is used vertically, drill .25 inch diameter holes through the sides and bottom of the straight section and telescope fitting. Install .25−20x.5 screws and secure with cap nuts and lockwashers.

  6. Calibrate the wireway

    After installation, verify that all sections are securely fastened and that gaskets are properly seated to prevent any leaks. Use a multimeter to check for grounding continuity if applicable.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.