The nVent F66LC is a 6.00x6.00 inch steel cross fitting designed for efficient wire and cable management. Manufactured by nVent, this gray fitting (SKU: F66LC) provides a four-way junction point for wireway runs where all branches originate from the same side. Its lay-in design simplifies installation, allowing cables to be placed directly into the fitting without complex threading. The hinged cover ensures secure closure and provides convenient access for maintenance and inspections. Constructed from durable steel, the F66LC offers excellent mechanical protection and longevity in demanding industrial and commercial environments. The ANSI 61 gray polyester powder paint finish provides a professional aesthetic and corrosion resistance. This fitting is ideal for industrial automation, data centers, commercial buildings, and manufacturing plants. Key benefits include efficient four-way cable routing, simplified installation via the lay-in design, secure and accessible operation with a hinged cover, and durable steel construction for reliability. This fitting is UL 870 Listed and cUL Listed per CSA C22.2 No. 26, meeting NEMA/EEMAC Type 1 and IEC 60529 standards. It is designed to protect electrical wiring in applications where dust, dirt, oil, and water are not serious problems.
  • Lay-in Hinged-Cover Cross Fittings are used for routing cables in four directions in wireway runs
  • Used when there are four branches, all open along the same side
  • Hinged cover for secure closure and easy access
  • Four-way junction for cables originating from the same side
  • ANSI 61 gray polyester powder paint finish
  • UL 870 Listed; cUL Listed per CSA C22.2 No. 26
  • NEMA/EEMAC Type 1 and IEC 60529 compliant

Specifications

Application
Power Distribution
Color
Gray
Color Code
ANSI 61
Finish
Galvanized;Painted
Finish
Painted Steel
Height
44 IN
Height
6 in
Height
152.4 mm
IP Rating
IP54
Material
Steel
Material
Mild Steel;Steel
Modification Services
Yes
NEMA Rating
12
NEMA Rating
12 Indoor, dust-resistant
Protection Rating
NEMA Type 12
Sealing Plate Quantity
3
Sealing Plate Type
Flat
Thickness
14 ga
Thickness
51.40mm (2.024")
Thickness
1.9 mm
Type
Industrial Lay-in Wireway
Type
Commercial Lay-in Painted Galvanized Hinged-cover Type 3R Wireway;Cross Fitting
Type Number
Type 12
Weight
13.66 lb
Width
6
Width
152
Width
23 IN
Wireway
Lay-In NEMA Type 12 Wireway
Package Dimensions (L x W x H)
12.5 IN x 12 IN x 10 IN
Package Dimensions (L x W x H)
31.75 cm x 30.48 cm x 25.4 cm
Package Weight (Imperial)
13.800 L
Package Weight (Metric)
6.260 kg
Elbow 90-Degree Outside Top Opening, 6.00x6.00, Gray, Steel

F66LE9AC

Elbow 90-Degree Outside Top Opening, 6.00x6.00, Gray, Steel
N12 Wireway, Cut-Off Fitting, Lay-In - Fits 12 x 6 - Steel/Gray

1485FW1

N12 Wireway, Cut-Off Fitting, Lay-In - Fits 12 x 6 - Steel/Gray
Wire Safe Fitting - 6 inch X 6 Inch External Coupling.

EGCER

Wire Safe Fitting - 6 inch X 6 Inch External Coupling.
Twin-70 raceway base, 10 foot length. Supplied with pre-punched mounting holes. 2' of cover needed for every 1' of Twin-70 base.

T702BIW10

Twin-70 raceway base, 10 foot length. Supplied with pre-punched mounting holes. 2' of cover needed for every 1' of Twin-70 base.

How to Install the F66LC Wireway

This guide provides step-by-step instructions for installing and configuring the F66LC wireway system, ensuring proper assembly and sealing for optimal performance.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Drill, Wrench

Supplies needed:

Mounting screws, Gaskets, Terminal connectors, Sealant

  1. Assemble the wireway sections

    Place a gasket between the flanges of the wireway sections and secure them using screws and nuts as shown in the installation details.

  2. Seal the joints

    After installing the wires, seal each joint between sections using either the LSGQR fitting method or the 90° angle sealing plate method as described in the installation instructions.

  3. Install the box entries

    Make a cutout in the control enclosure for the wireway entry, position the box connector and gasket inside, and install a 90° angle sealing plate to ensure a secure fit.

  4. Adjust the telescope fitting

    Assemble the compression ring, gasket, and retainer on the telescope fitting, insert it into the straight section, and adjust to the desired length before securing it with screws.

  5. Anchor the telescope fitting

    Drill .25 inch diameter holes through the sides and bottom of the straight section and telescope fitting, then install .25−20x.5 screws with cap nuts and lockwashers to secure the fitting.

  6. Calibrate the wireway

    Ensure that all sections are level and securely fastened, and verify that the wireway is properly grounded if applicable.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.