nVent F66LE9AC - Elbow 90-Degree Outside Top Opening, 6.00x6.00, Gray, Steel
nVent

F66LE9AC

UPC: 783510195007


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent F66LE9AC is a robust 90-degree outside elbow designed for efficient and organized industrial wireway installations. Manufactured by nVent, a trusted leader in electrical enclosure and connection solutions, this elbow fitting (SKU: F66LE9AC) is engineered to facilitate seamless right-angle transitions in your conduit and cable management systems. Its primary function is to enable a vertical drop to equipment situated below at a 90-degree corner, while crucially maintaining the convenient top opening lay-in feature. This design significantly simplifies the installation and maintenance process, allowing for easy access to conductors without the need for pulling through the entire fitting. Constructed from durable steel and finished in a standard industrial gray, the nVent F66LE9AC is built to withstand demanding environments. The 6.00x6.00 inch dimensions ensure compatibility with a wide range of standard wireway systems, providing ample space for multiple conductors. The hinged cover mechanism is a key differentiator, offering secure closure and protection for the enclosed wiring while allowing for quick and tool-less access when modifications or inspections are required. This feature is invaluable in industrial settings where uptime and efficient maintenance are paramount. Applications for the nVent F66LE9AC are diverse, spanning numerous industries including: * **Manufacturing and Automation:** Routing power and control cables to machinery, robotic arms, and assembly lines. * **Data Centers:** Managing network cabling and power distribution in a structured and accessible manner. * **Commercial Buildings:** Facilitating electrical distribution in complex architectural layouts. * **Utilities and Infrastructure:** Protecting and organizing critical wiring in substations and control rooms. The outside top opening design of this 90-degree elbow is particularly advantageous for installations where space is constrained or where direct access to the wireway is needed from above. Professionals will appreciate the ease with which cables can be laid into the elbow, reducing installation time and labor costs. The robust steel construction offers excellent physical protection against impacts and environmental factors, ensuring the longevity and reliability of your electrical infrastructure. When selecting wireway fittings, choosing components from reputable manufacturers like nVent guarantees adherence to industry standards and a commitment to quality and performance. The F66LE9AC exemplifies this commitment, providing a dependable solution for complex wiring challenges.
  • Lay-in Hinged-Cover 90-Degree Elbow with Outside Top Opening are used for right-angle wireway installations
  • This elbow fitting allows a vertical drop to equipment below at a 90-degree corner while maintaining the top opening lay-in feature
  • Hinged cover provides secure closure and easy maintenance.
  • Durable steel construction with industrial gray finish.
  • 6.00x6.00 inch dimensions suitable for standard wireway systems.

Specifications

Application
Power Distribution
Color
Gray
Color Code
ANSI 61
Finish
Galvanized
Height
44 IN
Height
6
Height
152
IP Rating
IP54
Material
Mild Steel
Material
Steel
Modification Services
Yes
NEMA Rating
12 Indoor, dust-resistant
NEMA Rating
12
Protection Rating
NEMA Type 12
Sealing Plate Quantity
2
Sealing Plate Type
Flat
Size
6.00x6.00
Thickness
51.40mm (2.024")
Thickness
1.9 mm
Thickness
14 ga
Type
Elbow
Type
Elbow;Industrial Lay-in Wireway
Type Number
Type 12
Weight
12.2 lb
Width
23 IN
Width
6
Width
152
Wireway
Lay-In NEMA Type 12 Wireway
Package Dimensions (L x W x H)
10.4 IN x 10 IN x 11.5 IN
Package Dimensions (L x W x H)
26.416 cm x 25.4 cm x 29.21 cm
Package Weight (Imperial)
12.200 L
Package Weight (Metric)
5.534 kg
Tee Fitting Lay-in Hinged Cover Outside Top Opening, 6.00x6.00, Gray, Steel

F66LTC

Tee Fitting Lay-in Hinged Cover Outside Top Opening, 6.00x6.00, Gray, Steel
N12 Wireway, Cut-Off Fitting, Lay-In - Fits 12 x 6 - Steel/Gray

1485FW1

N12 Wireway, Cut-Off Fitting, Lay-In - Fits 12 x 6 - Steel/Gray
Wire Safe Fitting - 6 inch X 6 Inch External Coupling.

EGCER

Wire Safe Fitting - 6 inch X 6 Inch External Coupling.
The LDPH10 power rated Surface Raceway is a two-piece latching raceway with cover suitable for applications up to 600 V. It features pre-punched mounting holes and factory-applied adhesive backing for fast mounting. It is 6 feet in length and is 1.52 inches wide by 0.86 inches deep. It meets TIA/EIA Standards, is UL5A Listed, and is UL Compliant. It is International Gray.

LDPH10IG6-A

The LDPH10 power rated Surface Raceway is a two-piece latching raceway with cover suitable for applications up to 600 V. It features pre-punched mounting holes and factory-applied adhesive backing for fast mounting. It is 6 feet in length and is 1.52 inches wide by 0.86 inches deep. It meets TIA/EIA Standards, is UL5A Listed, and is UL Compliant. It is International Gray.

How to Install the Lay-In Wireway

This guide provides step-by-step instructions for installing and configuring the Lay-In Wireway for effective cable management.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Drill, Wrench

Supplies needed:

Mounting screws, Gaskets, Terminal connectors, Nuts, Lockwashers

  1. Assemble the wireway sections

    Place a gasket between the flanges of the wireway sections and secure them using screws and nuts as shown in the installation details.

  2. Seal the joints

    After installing the wires, seal each joint between sections using either the LSGQR fitting method or the 90° angle sealing plate method, ensuring all gaskets are properly positioned.

  3. Install box entries

    Make a cutout in the control enclosure as specified, position the box connector and gasket inside, and install a sealing plate to ensure a secure fit.

  4. Adjust telescope fitting

    Assemble the compression ring, gasket, and retainer on the telescope fitting, insert it into the straight section, and adjust to the desired length before securing with screws.

  5. Anchor the telescope fitting

    If the telescope fitting is used in a vertical position, drill holes through the fitting and straight section, then install screws and cap nuts to secure it in place.

  6. Calibrate and test

    Ensure all connections are tight and verify grounding continuity across the wireway to ensure proper operation.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.