The nVent F66L120 is a 120-inch straight section lay-in wireway designed for NEMA Type 12 applications. Constructed from durable steel and finished in neutral gray, this wireway provides robust protection for electrical wiring and cabling against dust, dirt, oil, and dripping water in harsh industrial environments. Its 6.00 x 6.00 x 120.00 inch dimensions accommodate substantial cable runs, making it ideal for manufacturing plants, processing facilities, and automotive assembly lines. The lay-in design eliminates the need for pulling wires, significantly reducing installation time and complexity. The hinged cover features quick-release latches for fast access during inspections, maintenance, or modifications, minimizing downtime. Available with or without knockouts, the F66L120 integrates seamlessly into comprehensive wire management systems. Manufactured by nVent, a trusted leader in electrical enclosure solutions, this wireway upholds the brand's reputation for quality and reliability in demanding industrial settings.
  • Lay-in NEMA Type 12 Wireway fittings are used primarily in industrial applications to protect wiring against exposure to oil and other contaminants
  • This gasketed wireway features quick-release latches for easy access and an opening on one side so wires and cables can be laid in along the entire run without pulling
  • Lay-in design eliminates wire pulling for faster installation
  • Hinged cover with quick-release latches for easy access
  • Available with or without knockouts for flexible installation

Specifications

Application
Power Distribution
Color
Gray
Color Code
ANSI 61
Depth
120 in
Depth
3,048 mm
Depth
13 IN
Finish
Galvanized;Painted
Finish
Galvanized
Height
44 IN
Height
6
Height
152
IP Rating
IP54
Material
Mild Steel;Steel
Material
Mild Steel
Material
Steel
Modification Services
Yes
Nema Rating
Type 12
NEMA Rating
12 Indoor, dust-resistant
NEMA Rating
12
Protection Rating
NEMA Type 12
Sealing Plate Quantity
1
Sealing Plate Type
Flat
Series
F66L
Size
6.00x6.00x120.00 in
Thickness
1.9 mm
Thickness
14 ga
Thickness
51.40mm (2.024")
Type
Straight Section
Type
Industrial Lay-in Wireway;Straight Section
Type Number
Type 12
Weight
70 lb
Width
6
Width
152
Width
23 IN
Wireway
Lay-In NEMA Type 12 Wireway
Package Dimensions (L x W x H)
123.25 IN x 8 IN x 8 IN
Package Dimensions (L x W x H)
313.055 cm x 20.32 cm x 20.32 cm
Package Weight (Imperial)
70.000 L
Package Weight (Metric)
31.752 kg
Straight Section Lay-in Hinged Cover Type 12, 6.00x6.00x60.00, Gray, Steel

F66L60

Straight Section Lay-in Hinged Cover Type 12, 6.00x6.00x60.00, Gray, Steel
N12 Wireway, Cut-Off Fitting, Lay-In - Fits 12 x 6 - Steel/Gray

1485FW1

N12 Wireway, Cut-Off Fitting, Lay-In - Fits 12 x 6 - Steel/Gray
Wire Safe Fitting - 6 inch X 6 Inch External Coupling.

EGCER

Wire Safe Fitting - 6 inch X 6 Inch External Coupling.
The LDPH10 power rated Surface Raceway is a two-piece latching raceway with cover suitable for applications up to 600 V. It features pre-punched mounting holes and factory-applied adhesive backing for fast mounting. It is 6 feet in length and is 1.52 inches wide by 0.86 inches deep. It meets TIA/EIA Standards, is UL5A Listed, and is UL Compliant. It is International Gray.

LDPH10IG6-A

The LDPH10 power rated Surface Raceway is a two-piece latching raceway with cover suitable for applications up to 600 V. It features pre-punched mounting holes and factory-applied adhesive backing for fast mounting. It is 6 feet in length and is 1.52 inches wide by 0.86 inches deep. It meets TIA/EIA Standards, is UL5A Listed, and is UL Compliant. It is International Gray.

How to Install the F66L120 Controller

This guide provides step-by-step instructions for installing and configuring the F66L120 controller, including mounting, wiring, and initial setup.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors, Gaskets

  1. Mount the controller

    Secure the F66L120 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the wiring

    Use wire strippers to prepare the wires and connect them to the appropriate terminals on the controller. Ensure all connections are tight and secure.

  3. Verify electrical connections

    Use a multimeter to check the voltage and continuity of the connections to ensure they are functioning correctly before powering on the controller.

  4. Power on the controller

    Once all connections are verified, power on the F66L120 controller and observe the startup sequence for any error indicators.

  5. Configure initial settings

    Access the controller's configuration menu and set the initial parameters as required for your application. Refer to the user manual for specific settings.

  6. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure the controller operates within the desired specifications.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.