Contact for Pricing
Overview
- Lay-in NEMA Type 12 Wireway fittings are used primarily in industrial applications to protect wiring against exposure to oil and other contaminants
- This gasketed wireway features quick-release latches for easy access and an opening on one side so wires and cables can be laid in along the entire run without pulling
- Lay-in design eliminates wire pulling for faster installation
- Hinged cover with quick-release latches for easy access
- Available with or without knockouts for flexible installation
Specifications
Application | Power Distribution |
Color | Gray |
Color Code | ANSI 61 |
Depth | 120 in |
Depth | 3,048 mm |
Depth | 13 IN |
Finish | Galvanized;Painted |
Finish | Galvanized |
Height | 44 IN |
Height | 6 |
Height | 152 |
IP Rating | IP54 |
Material | Mild Steel;Steel |
Material | Mild Steel |
Material | Steel |
Modification Services | Yes |
Nema Rating | Type 12 |
NEMA Rating | 12 Indoor, dust-resistant |
NEMA Rating | 12 |
Protection Rating | NEMA Type 12 |
Sealing Plate Quantity | 1 |
Sealing Plate Type | Flat |
Series | F66L |
Size | 6.00x6.00x120.00 in |
Thickness | 1.9 mm |
Thickness | 14 ga |
Thickness | 51.40mm (2.024") |
Type | Straight Section |
Type | Industrial Lay-in Wireway;Straight Section |
Type Number | Type 12 |
Weight | 70 lb |
Width | 6 |
Width | 152 |
Width | 23 IN |
Wireway | Lay-In NEMA Type 12 Wireway |
Package Dimensions (L x W x H) | 123.25 IN x 8 IN x 8 IN |
Package Dimensions (L x W x H) | 313.055 cm x 20.32 cm x 20.32 cm |
Package Weight (Imperial) | 70.000 L |
Package Weight (Metric) | 31.752 kg |

LDPH10IG6-A
The LDPH10 power rated Surface Raceway is a two-piece latching raceway with cover suitable for applications up to 600 V. It features pre-punched mounting holes and factory-applied adhesive backing for fast mounting. It is 6 feet in length and is 1.52 inches wide by 0.86 inches deep. It meets TIA/EIA Standards, is UL5A Listed, and is UL Compliant. It is International Gray.How to Install the F66L120 Controller
This guide provides step-by-step instructions for installing and configuring the F66L120 controller, including mounting, wiring, and initial setup.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Wire connectors, Gaskets
- Mount the controller
Secure the F66L120 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.
- Connect the wiring
Use wire strippers to prepare the wires and connect them to the appropriate terminals on the controller. Ensure all connections are tight and secure.
- Verify electrical connections
Use a multimeter to check the voltage and continuity of the connections to ensure they are functioning correctly before powering on the controller.
- Power on the controller
Once all connections are verified, power on the F66L120 controller and observe the startup sequence for any error indicators.
- Configure initial settings
Access the controller's configuration menu and set the initial parameters as required for your application. Refer to the user manual for specific settings.
- Calibrate the controller
Follow the calibration procedure outlined in the user manual to ensure the controller operates within the desired specifications.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.