The nVent F66BK60 Barrier Divider Wireway Kit Bolt-On is a factory-engineered solution for dividing 6.00 x 6.00-inch wireway sections into isolated compartments. Manufactured by nVent, a global leader in electrical connectivity, this kit ensures organized cable management and enhanced electrical safety in industrial, commercial, and institutional applications. Key specifications include a 4.50-inch (114 mm) barrier width, 60.00-inch (1524 mm) length, and durable mild steel construction with a corrosion-resistant gray finish. The bolt-on design features pre-punched mounting holes and includes sealing washers to maintain IP-rated protection against dust and moisture ingress when used with compatible nVent wireway systems. Compatible with NEMA Type 12 and IEC 60529 IP66 environments, the F66BK60 supports compliance with NEC and IEC wiring standards. Typical applications include power distribution panels, data centers, manufacturing facilities, and renewable energy installations where cable segregation is critical for safety and performance. The barriers effectively separate high-voltage power cables from low-voltage control wiring, minimizing crosstalk and simplifying troubleshooting.
  • Divides wireway into two or more compartments
  • Barriers are fastened to wireway sections with screws. Sealing washers are included
  • Bolt-on design with pre-punched mounting holes and sealing washers
  • Durable mild steel construction with corrosion-resistant gray finish
  • Maintains IP-rated protection (NEMA Type 12, IEC 60529 IP66) when used with compatible nVent wireway systems

Specifications

Application
Power Distribution
Color
Gray
Color Code
ANSI 61
Depth
0.62 in
Depth
13 IN
Finish
Painted;Powder Coat
Finish
Powder Coated
Height
44 IN
Height
4.5 in
Height
2.52
Height
64
Material
Mild Steel
Material
Mild Steel;Steel
Modification Services
Yes
NEMA Rating
12 Indoor, dust-resistant
NEMA Rating
12
Protection Rating
NEMA Type 12
Thickness
16 ga
Thickness
1.52 mm
Thickness
51.40mm (2.024")
Type
Barrier Kit
Type
Barrier Kit;Industrial Feed-Through Wireway
Weight
8 lb
Width
2.5
Width
64
Width
23 IN
Width
59.75 in
Wireway
Lay-In NEMA Type 1 Hinged-Cover Wireway
Package Dimensions (L x W x H)
64 IN x 6.25 IN x 5.75 IN
Package Dimensions (L x W x H)
162.56 cm x 15.875 cm x 14.605 cm
Package Weight (Imperial)
8.000 L
Package Weight (Metric)
3.629 kg
Barrier Divider Wireway Kit Bolt-On, fits 4.00x4.00, Gray, Mild Steel

F44BK60

Barrier Divider Wireway Kit Bolt-On, fits 4.00x4.00, Gray, Mild Steel
N4/12 Wiring Trough - 2.5 x 2.5 x 24 - Steel/Gray

1486B24

N4/12 Wiring Trough - 2.5 x 2.5 x 24 - Steel/Gray
The LD10 Surface Raceway channel is a one-piece latching channel with integrated cover and is designed to route, protect, and conceal data, voice, and video cabling. It features a factory-applied adhesive backing for fast mounting. It is 8 feet in length and is 1.5 inches wide by 0.94 inches deep. It meets TIA/EIA, used in applications up to 50 V. It is constructed of rigid PVC and is International Gray.

LD10IG8-A

The LD10 Surface Raceway channel is a one-piece latching channel with integrated cover and is designed to route, protect, and conceal data, voice, and video cabling. It features a factory-applied adhesive backing for fast mounting. It is 8 feet in length and is 1.5 inches wide by 0.94 inches deep. It meets TIA/EIA, used in applications up to 50 V. It is constructed of rigid PVC and is International Gray.
Wire Safe Fitting - 6 inch X 6 Inch External Coupling.

EGCER

Wire Safe Fitting - 6 inch X 6 Inch External Coupling.

How to Install the Lay-In Wireway

This guide provides step-by-step instructions for installing and sealing a Lay-In Wireway for effective cable management.

Estimated time: 1h

Tools needed:

Screwdriver, Drill, Wrench

Supplies needed:

Mounting screws, Gaskets, Nuts, Sealing plates

  1. Assemble the wireway sections

    Place a gasket between the flanges of the wireway sections and secure them using screws and nuts as shown in the installation details.

  2. Seal the joints

    For joints between lay-in sections, use the LSGQR fitting and install it by leaving out the top flange screw on the hinge side. Ensure gaskets are visible and rotate the cam to lock.

  3. Make box entries

    Cut out the necessary openings in the control enclosure as specified, position the box connector and gasket inside, and install a 90° angle sealing plate as described.

  4. Adjust telescope fitting

    Assemble the compression ring, gasket, and retainer on the telescope fitting body. Insert it into the straight section and adjust to the desired length.

  5. Anchor the telescope fitting

    Drill .25 inch diameter holes through the sides and bottom of the straight section and telescope fitting. Install .25−20x.5 screws and secure with cap nuts and lockwashers.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.