Authorized nVent Distributor
nVent D723646SDA - Seismic Free-Stand DA Cabinet Type 12, 72x36x46, Lt Gray, Steel

nVent D723646SDA Seismic Free-Stand DA Cabinet Type 12, 72x36x46, Lt Gray, Steel

UPC: 783510354473


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent D723646SDA is a Type 12 seismic free-standing cabinet designed for robust industrial applications. Constructed from 12-gauge steel with continuously welded seams and unibody construction, this cabinet ensures structural integrity. The 72x36x46 inch dimensions provide ample internal space. For enhanced rigidity on two-door models, back stiffeners are included. The cabinet is equipped with lifting eyes for easy handling and a 3-point latching system with an oil-tight, key-locking handle. Concealed, removable hinges facilitate maintenance. Internal mounting channels are welded horizontally at the top, bottom, and center, allowing for flexible placement of optional panels and rack angles. High-impact thermoplastic data pockets and an oil-resistant door gasket contribute to its functionality. This cabinet meets NEBS-Telcordia GR-63-CORE Zone 4 seismic standards when used with optional accessories. An optional white interior is available. Compatible with a range of nVent accessories including seismic anchor kits, bonding kits, panels, PDUs, heaters, and cooling products.
  • Six seismic bottom-mounting plates made of painted plated steel for 5/8-inch diameter anchors
  • Lifting eyes installed for ease of handling
  • Rack angles included are infinitely adjustable from front-to-rear supporting multiple networking/communication equipment configurations
  • AC models available for heat management
  • Data pockets included for equipment information management/organization
  • Data pockets are high-impact thermoplastic
  • Internal mounting channels welded horizontally to sides at top, bottom and center
  • 36-in. wide models include 2 Seismic Rack Panel Kits with EIA 310 specified square-holes (.375 x .375) that are infinitely adjustable front to rear

Specifications

Application
Datacom and Telecom Equipment;Networking, Storage and Data Center
Color
Light Gray
Color
Gray
Color Code
RAL 7035
Depth
46.16 in
Depth
1,173 mm
Finish
Powder Coated
Height
72.22 in
Height
1,834 mm
Material
Mild Steel
Modification Services
Yes
Product Type
Standard
Rack Units
35 U
Thickness
2.66 mm
Thickness
12 ga
Thickness
51.40mm (2.024")
Type
Data Networking Freestanding Cabinets
Weight
720 lb
Width
918 mm
Width
36.14 in
Package Dimensions (L x W x H)
60 IN x 45 IN x 81 IN
Package Dimensions (L x W x H)
152.4 cm x 114.3 cm x 205.74 cm
Package Weight (Imperial)
720.000 L
Package Weight (Metric)
326.592 kg
Seismic Free-Stand DA Cabinet AC Type 12, 72x36x46, Lt Gray, Steel

D723646SDAAC

Seismic Free-Stand DA Cabinet AC Type 12, 72x36x46, Lt Gray, Steel
DTT 6201 230V SC 7035

13256241055

DTT 6201 230V SC 7035
AC Unit 9-12,000 BTU/H 230V

DTS3245A230LG

AC Unit 9-12,000 BTU/H 230V
Seismic Free-Stand DA Cabinet Type 3R 4 4X 12, 72x24x36, Brushed, SS304

D722436SDAS

Seismic Free-Stand DA Cabinet Type 3R 4 4X 12, 72x24x36, Brushed, SS304
Seismic Free-Stand DA Cabinet Type 3R 4 4X 12, 90x24x36, Brushed, SS304

D902436SDAS

Seismic Free-Stand DA Cabinet Type 3R 4 4X 12, 90x24x36, Brushed, SS304
SpectraCool Advanced Corrosion Protection Lvl 2, 4000BTU 115V, Lt Gray, Steel

G280416G800

SpectraCool Advanced Corrosion Protection Lvl 2, 4000BTU 115V, Lt Gray, Steel
T-Series Mid-Size Outdoor with Heat T53, 19000BTU 230V, Brushed, SS304

T531926G151

T-Series Mid-Size Outdoor with Heat T53, 19000BTU 230V, Brushed, SS304
SpectraCool Advanced Corrosion Protection Lvl 1, 4000BTU 115V, Lt Gray, Steel

G280416G700

SpectraCool Advanced Corrosion Protection Lvl 1, 4000BTU 115V, Lt Gray, Steel

How to Safely Handle and Install Large Hoffman Enclosures

This guide provides instructions for safely handling and installing large Hoffman enclosures, emphasizing precautions to prevent injury and equipment damage.

Estimated time: 1h

Tools needed:

Forklift, Overhead lifting device (e.g., crane), Slings with load-rated hooks or shackles, ROLL•A•LIFT™ or similar device (for some models)

Supplies needed:

3000 lb.-rated chain or strap (for securing to forklift mast), Rigging equipment (for overhead lifting)

  1. Read Safe Handling Requirements

    Before moving or installing the enclosure, thoroughly read and understand the 'Large Enclosure Safe Handling Requirements' document that accompanied the enclosure. Ensure the route is clear of obstructions and all personnel are at a safe distance.

  2. Prepare for Movement

    Ensure the enclosure is stabilized before removing any strapping. Verify that the lifting equipment (forklift or overhead device) has a sufficient load rating for the enclosure's weight and size. Only trained and authorized personnel should operate the lifting equipment.

  3. Position Forklift Forks

    For forklift handling, spread the forks to the maximum distance or as dictated by the skid width. Enter the skid from the rear (Side A) of the enclosure. Position the enclosure carefully on the forks, keeping the load against the carriage/mast and tilting the load backward towards the mast.

  4. Secure Enclosure to Forklift

    If using a forklift, secure the enclosure to the forklift mast before moving. Insert a 3000 lb.-rated chain or strap through the eye bolts provided on top of the enclosure and fasten it securely to the forklift mast assembly. Ensure sufficient tension to prevent tipping.

  5. Lift and Transport Enclosure

    Lift the enclosure a minimum distance so the skid is just clear of the floor. Start and stop the forklift slowly and gradually, avoiding jerky movements. Drive slowly with the forks carried as low to the ground as possible. Never attempt to move more than one enclosure at a time.

  6. End Loading/Unloading (if applicable)

    For end loading/unloading on trailers, spread forks to match pallet end slot openings and enter from the narrow side (C or D). Secure the enclosure to the forklift mast using chains or straps. Tilt the mast to take weight off the opposite end and slide/push the enclosure as required. Do not use chains or straps to lift the enclosure.

  7. Overhead Lifting (if applicable)

    If using overhead lifting, attach rigging to the eye bolts, ensuring the angle between lifting cables and the vertical does not exceed 45 degrees. Use slings with adequate load-rated hooks or shackles. Ensure the load rating of the lifting device and rigging is sufficient. Do not use ropes or cables through eye bolts.

  8. Final Placement

    Once the enclosure is at its final location, carefully position it. Ensure it is stable and permanently installed according to any specific product instructions not covered in this general handling guide. Refer to the nameplate or datasheet for model-specific details.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.