nVent CSD303010 - Concept Single-Door Enclosure, 30.00x30.00x10.00, Gray, Steel

nVent CSD303010 Concept Single-Door Enclosure, 30.00x30.00x10.00, Gray, Steel

UPC: 783510375393


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent CSD303010 Concept Single-Door Enclosure is a steel enclosure with external dimensions of 30.00 x 30.00 x 10.00 inches (762 x 762 x 254 mm). Constructed from 14-gauge steel, it features a durable ANSI 61 gray finish for corrosion resistance and a streamlined design with flush quarter-turn latches for secure closure. The enclosure includes a conductive panel for grounding and EMC compliance, with removable hinges allowing a 210° door opening. Mounting dimensions are 28.50 x 28.50 inches (724 x 724 mm), accommodating a panel size of 28.20 x 28.20 inches (716 x 716 mm). Designed for wall-mounting with required brackets, it meets Type 4, 12, and 13 NEMA ratings and IP66 per IEC 60529, providing protection against dust, water, and oil ingress. Ideal for industrial control panels, automation systems, and equipment protection in manufacturing, food processing, water treatment, and petrochemical environments.
  • External dimensions: 30.00 x 30.00 x 10.00 inches (762 x 762 x 254 mm)
  • 14-gauge steel construction with ANSI 61 gray finish
  • Flush quarter-turn latches with 210° door opening
  • Conductive panel included for grounding and EMC compliance
  • Type 4, 12, 13 NEMA and IP66 rated for dust, water, and oil resistance
  • Door opens 210 degrees
  • External formed body flange
  • Panel mounting studs fit optional Concept panels and other accessories
  • Mounting holes in back of body for optional external wall-mount brackets
  • Removable door with hidden hinges for clean, aesthetic appearance

Specifications

Application
Controls and Drives
Body Thickness
1.9 mm
Body Thickness
14 ga
Body Thickness
16 ga
Color
Gray
Color Code
ANSI 61
Concept Panel
CP3030
Conductive Concept Panel
CP3030G
Depth
10 IN
Depth
254 mm
Door Thickness
1.9 mm
Door Thickness
14 ga
Finish
Powder Coated
Height
30 IN
Height
762 mm
IP Rating
IP66
Latch Quantity
2
Latch Style
Quarter-turn
Latch Type
Quarter-turn
Material
Mild Steel
Material
Steel
Modification Services
Yes
Mounting
28.50 x 28.50 in
Mounting
Wall Mounting Brackets Available
Mounting Type
Wall-mount
NEMA Rating
12 Indoor, dust-resistant
NEMA Rating
12
Nema Rating
TYPE 4/12
Panel Size
716 x 716 mm
Panel Size
28.20 x 28.20 in
Product Family
Concept
Protection Rating
NEMA Type 12
Series
Concept
Size
30.00x30.00x10.00 inches
Size
30.00x30.00x10.00 in
Type
Mild Steel Wall Mounted Industrial Enclosures
Type Number
Type 4
Weight
73 lb
Width
762 mm
Width
30 IN
Package Dimensions (L x W x H)
34.7 IN x 31.5 IN x 12 IN
Package Dimensions (L x W x H)
88.138 cm x 80.01 cm x 30.48 cm
Package Weight (Imperial)
73.000 L
Package Weight (Metric)
33.113 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the CSD303010 Wall-Mount Enclosure

Follow these instructions to properly mount and install your CSD303010 wall-mount enclosure.

Estimated time: 1h

Tools needed:

Drill, Level, Measuring tape, Screwdriver, Wrench or socket set

Supplies needed:

Mounting hardware (screws, anchors, bolts), Gasket (if applicable), Sealing fittings (if applicable)

  1. Select Mounting Location

    Choose a suitable location for the enclosure. Ensure the mounting surface is strong enough to support the weight of the enclosure and its contents. Consider environmental factors such as temperature, humidity, and potential exposure to corrosive elements. Refer to the datasheet for specific environmental ratings.

  2. Prepare the Enclosure

    If necessary, install any required accessories such as internal mounting panels, gland plates, or door stops. Ensure the gasket is properly seated around the door flange for a watertight seal. If using sealing fittings for cable entry, install them according to their specific instructions.

  3. Mark Mounting Holes

    Hold the enclosure in the desired position against the mounting surface. Use a level to ensure it is straight. Mark the locations for the mounting holes through the designated mounting points on the back of the enclosure or the internal mounting panel.

  4. Drill Mounting Holes

    Remove the enclosure from the mounting surface. Drill the mounting holes at the marked locations. If mounting to a concrete or masonry surface, use appropriate masonry bits and install anchors. If mounting to a metal surface, ensure the holes are appropriately sized for the chosen fasteners.

  5. Mount the Enclosure

    Position the enclosure over the drilled holes. Secure the enclosure to the mounting surface using appropriate hardware (screws, bolts, etc.). Ensure the enclosure is firmly attached and does not move. Use a wrench or socket set for tightening bolts as needed.

  6. Install Equipment and Wiring

    Install any internal equipment according to its specific instructions. Route wiring through the appropriate conduit or cable entries, ensuring proper strain relief and sealing. Refer to the wiring diagrams provided with the equipment and the enclosure datasheet for guidance on wire management and sealing.

  7. Final Inspection

    Close and latch the enclosure door securely. Verify that all seals are properly engaged and that the enclosure is watertight or weatherproof as required by its rating. Double-check that all mounting hardware is tight and that the installation is secure.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.