nVent CDSC24228SS - Concept Wallmount Disconnect Enclosure 3Pt Latch, 24x22x8, Brushed, SS304
nVent

CDSC24228SS

UPC: 783510127541


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent Concept Wallmount Disconnect Enclosure (SKU: CDSC24228SS) is a premium Type 4X stainless steel enclosure designed for industrial and commercial applications requiring robust protection and reliable performance. Engineered by nVent, a global leader in electrical and thermal management solutions, this enclosure combines durability, corrosion resistance, and precision engineering to meet the demands of harsh environments. With a brushed SS304 finish and a 3-point latch mechanism, it ensures secure closure while providing Type 4X protection against dust, water, and corrosion—ideal for outdoor or wet-location installations. Designed to accommodate major brand disconnect switches and circuit breakers, the Concept Wallmount Disconnect Enclosure offers a standardized cutout that simplifies installation and ensures compatibility with industry-leading components. Its 24x22x8-inch dimensions provide ample space for housing critical electrical components, while the wallmount design allows for easy integration into control panels, machinery, or facility infrastructure. The stainless steel construction delivers exceptional strength and longevity, making it a cost-effective choice for long-term deployments in manufacturing plants, utilities, food processing facilities, and marine applications. Key features of the nVent Concept Wallmount Disconnect Enclosure include: - **Type 4X Rating**: Provides protection against corrosion, dust ingress, and hose-directed water, ensuring reliable operation in challenging conditions. - **Brushed SS304 Construction**: Offers superior corrosion resistance and a professional aesthetic, suitable for both indoor and outdoor use. - **3-Point Latch Mechanism**: Enhances security and prevents accidental openings, critical for safety in high-vibration environments. - **Standardized Cutout Design**: Compatible with major brand disconnect switches and circuit breakers, reducing installation complexity and downtime. - **Wallmount Configuration**: Facilitates easy mounting on walls or control panels, optimizing space utilization in industrial settings. Industries that benefit from the nVent Concept Wallmount Disconnect Enclosure include oil and gas, chemical processing, water treatment, renewable energy, and food and beverage. Its Type 4X rating makes it particularly valuable in facilities where exposure to moisture, chemicals, or particulate matter is a concern. Professionals in these sectors rely on nVent’s reputation for innovation and quality, ensuring that their electrical enclosures meet stringent safety and performance standards. Installation is straightforward, with pre-drilled mounting holes and a design that aligns with common industry practices. The enclosure’s modularity allows for easy upgrades or replacements, reducing maintenance costs over time. For engineers and facility managers seeking a dependable, high-performance disconnect enclosure, the nVent Concept Wallmount Disconnect Enclosure (CDSC24228SS) delivers unmatched reliability and value.
  • Disconnect model of Concept enclosure series, includes 3 point latching for closure.
  • Seams continuously welded and ground smooth
  • External-formed 90-degree body flange
  • Integral door ramp to properly align door and gasket to body flange
  • Holes provided in right-hand flange are for mounting disconnect operating handle and operating mechanism
  • Panel mounting studs fit optional Concept panels and other accessories (purchase panels separately)
  • Mounting holes in back of body for direct mounting or for optional external mounting brackets
  • Stainless steel hidden hinges
  • Standard full-access door opening
  • Corner formed doors are interchangeable and easily removable by pulling captive hinge pins

Specifications

Application
Corrosive Environments; Controls and Drives; Arc Flash Safety
Application
Arc Flash Safety;Controls and Drives;Corrosive Environments
Color
Brushed
Color
Unpainted
Concept Panel
CP2420
Conductive Panel
CP2420G
Depth
203 mm
Depth
8 mm
Finish
Brushed #4
Height
24 in
Height
610 mm
IP Rating
IP66
Material
SS304
Material
Stainless Steel;Stainless Steel 304
Material
Stainless Steel 304
Modification Services
Yes
Mounting
22.50 x 20.50 in
Mounting
Wall Mounting Brackets Available
Mounting Type
Wallmount
NEMA Rating
12 Indoor, dust-resistant
Nema Rating
Type 4X
NEMA Rating
12
Panel Size
22.20 x 18.20 in
Panel Size
564 x 462 mm
Product Family
Concept
Protection Rating
NEMA Type 12
Size
24x22x8 inches
Size
24.00x22.00x8.00 in
Stainless Steel Type
304
Thickness
1.98 mm
Thickness
14 ga
Thickness
51.40mm (2.024")
Type
Stainless Steel Wall Mounted Industrial Disconnect Enclosures
Type Number
Type 3R
Weight
44.1 lb
Width
559 mm
Width
22 IN
Package Dimensions (L x W x H)
29 IN x 23.4 IN x 10.2 IN
Package Dimensions (L x W x H)
73.66 cm x 59.436 cm x 25.908 cm
Package Weight (Imperial)
44.100 L
Package Weight (Metric)
20.004 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the CDSC24228SS Controller

This guide provides step-by-step instructions for installing and configuring the CDSC24228SS Controller, ensuring proper setup and operation.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Drill mounting panel

    Drill the mounting panel according to the manufacturer's instructions for the disconnect device to ensure proper fit and clearance.

  2. Install operating handle

    Attach the operating handle to the enclosure flange using the provided holes, following the disconnect manufacturer's instructions.

  3. Mount disconnect device

    Securely install the disconnect device onto the panel, adhering to the manufacturer's installation and adjustment guidelines.

  4. Install padlocking door handle

    Follow the provided figures to install the Concept padlocking door handle on the outside of the door, ensuring it operates correctly.

  5. Adjust door catch

    Utilize the installed door catch and door catch bracket to adjust for proper interlock with the disconnect operating handle, as per the manufacturer's instructions.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.