Contact for Pricing
Overview
- Delivery: Frame, protected hood + Inlay for CCFGS
- Description: An inverted cable entry system, the CCFO enables complete assembly from the outside of the enclosure. It is made of sturdy, glass-fiber reinforced plastic. The rubber seal helps ensure an optimal seal with IP66 protection. The CCFI comes prep
- Finish: Black
- Flammability: UL94 V-0
- Material: Polyamide 6.6 / TPE
- Pack quantity: 1pc
- Protection: IP66, NEMA 1, 4x, 12 (Indoor use only)
- Temperature resistance: -40°C to +120°C
- CCFO comes standard with inlay/divider for Small Grommet installation
- Grommets sold separately
Specifications
Application | Controls and Drives; Corrosive Environments |
Cable Entry Quantity | 4 |
Color | Black |
Cutout Size | 46x36 mm |
Cutout Size | 1.81 x 1.42 in |
Depth | 24.2 mm |
Depth | 0.95 in |
Finish | Untreated |
Height | 64 mm |
Height | 2.52 |
Height | 64 |
Material | Plastic |
Operating Temperature | -40-120 °C |
Operating Temperature | -40-248 °F |
Product Family | Cable Manager |
Protection Rating | NEMA Type 1 |
Type | Cable Entry Systems |
Weight | 0.198 lb |
Weight | 0.1 kg |
Width | 81 mm |
Width | 3.19 |
Width | 81 |
Works With | NEMA |
Package Dimensions (L x W x H) | 7 IN x 3 IN x 1 IN |
Package Dimensions (L x W x H) | 17.78 cm x 7.62 cm x 2.54 cm |
Package Weight (Imperial) | 0.200 L |
Package Weight (Metric) | 0.091 kg |

053-71411-17
Bushing for Watertight Strain Relief Connector with 1-1/2 Inch Hub Size, Cable Range 1.000-1.187
JBP1FSIG
Single gang power rated two-piece snap together outlet box. Box accepts Pan-Way Snap-On Faceplates. For use with Pan-Way T-45 or LD, LDP, LDPH, LDS profile raceways. 5.00"L x 3.26"W x 1.62"H (127.1mm x 82.7mm x 41.1mm). Breakouts for 1/2", 3/4", or 1" diameter conduit, International Gray.How to Install the CCFO14 Cable Entry Gland Plate
This guide provides step-by-step instructions for installing the CCFO14 cable entry gland plate, ensuring proper sealing and securing of cables.
Estimated time: 45m
Tools needed:
Screwdriver, Torque wrench
Supplies needed:
M5 stainless steel screws, Cable seals, Washers, Nuts
- Prepare the installation area
Ensure the installation area is clean and free of debris. Verify that the enclosure is suitable for the CCFO14 cable entry gland plate.
- Guide cables through the frame
Insert the cables through the frame of the CCFO14, ensuring that they are positioned correctly for sealing.
- Attach seals and assemble the hood
Attach the seals to the cables, then assemble the hood by inserting washers and nuts. Tighten the nuts from inside to a torque of 3 Nm (26 in-lbs).
- Secure the inlays
Click the inlays into position and ensure they are properly seated. Push the seals all the way in to ensure a tight fit.
- Finalize the installation
Snap the hood onto the frame and remove any optional locking bars if not needed. Press the tabs on the sides to secure the assembly.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.