nVent CCFI610 Cable Entry Gld Plt Connected Inside, CCFI, 106x70x20mm, Blk, Plastic
UPC: 783510583163
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Delivery: Frame + Inlay for CCFGS
- Description: CCFI cable entry is quick and easy to assemble. It is made of a sturdy, glass-fiber reinforced plastic. With an IP66 rating, the foam seal helps ensure an optimal seal. The system comes prepared with inlays to fit small grommets (CCFGS). CCFG
- Finish: Black
- Flammability: UL94 V-0
- Material: Polyamide 6.6 / TPE
- Pack quantity: 1pc
- Protection: IP66, NEMA 1, 4x, 12 (Indoor use only)
- Temperature resistance: -40°C to +120°C
- Grommets sold separately
- Alternate inlays/dividers for different grommet configurations sold separately
Specifications
Application | Controls and Drives;Corrosive Environments |
Application | Corrosive Environments; Controls and Drives |
Cable Entry Quantity | 6 |
Color | Black |
Cutout Size | 4.47 x 1.81 in |
Cutout Size | 113x46 mm |
Cutout Size | 18.69 x 7.19 in |
Depth | 19.6 mm |
Depth | 0.77 in |
Finish | Untreated |
Finish | Bare/Untreated |
Height | 44 IN |
Height | 4.17 in |
Height | 106 mm |
Height | 106 |
Material | Plastic |
Operating Temperature | -40-248 °F |
Operating Temperature | -40-120 °C |
Product Family | Cable Manager |
Protection Rating | NEMA Type 1 |
Type | Cable Entry Systems |
Weight | 0.176 lb |
Weight | 32 lbs./100ft |
Weight | 0.1 kg |
Width | 23 IN |
Width | 70 |
Width | 70 mm |
Width | 2.76 IN |
Works With | NEMA |
Package Dimensions (L x W x H) | 5 IN x 4 IN x 1 IN |
Package Dimensions (L x W x H) | 12.7 cm x 10.16 cm x 2.54 cm |
Package Weight (Imperial) | 0.180 L |
Package Weight (Metric) | 0.082 kg |

T70CIW8
The T-70 Power Rated Raceway Cover is designed to snap on to the base to create a tamper resistant cable routing solution along perimeter walls. It is 8 ft and Off WhiteFrequently Asked Questions
What is the material and flammability rating of the CCFI610?
The CCFI610 is made of Polyamide 6.6 / TPE plastic and has a UL94 V-0 flammability rating.
What is the operating temperature range for the CCFI610?
The CCFI610 can operate in temperatures ranging from -40°C to 120°C (-40 to 248°F).
What protection ratings does the CCFI610 offer?
The CCFI610 offers IP66, NEMA 1, 4x, and 12 protection ratings for indoor use only.
What are the dimensions of the CCFI610 cable entry?
The CCFI610 has dimensions of 106x70x20mm, with a cutout size of 4.47 x 1.81 inches.
How many cables can the CCFI610 accommodate?
The CCFI610 cable entry system can accommodate 6 cables.
Are grommets included with the CCFI610?
No, grommets for the CCFI610 need to be ordered separately.
What industry standards does the CCFI610 comply with?
The CCFI610 is UL 508A Component Recognized, UL94 V-0 Flammability rated, CE, and IP66 compliant.
What is the weight of the CCFI610?
The CCFI610 weighs 0.176lb.
What is the color of the CCFI610?
The CCFI610 is black in color.
How to Install the CCFI610 Cable Entry System
This guide provides step-by-step instructions for installing the CCFI610 cable entry system, ensuring proper mounting and wiring for optimal performance.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Prepare the installation area
Ensure the installation area is clean and free of debris. Verify that the mounting surface is suitable for the CCFI610 cable entry system.
- Mount the cable entry system
Secure the CCFI610 to the enclosure using four M5 stainless steel screws. Ensure the screws account for the 3mm thickness of the gland plate and are tightened to 3 Nm (26 in-lbs).
- Connect the cables
Insert the cables through the entry points of the CCFI610. Use terminal connectors to secure the connections, ensuring that they are properly insulated and protected.
- Verify the installation
Use a multimeter to check the continuity of the connections. Ensure that all cables are securely attached and that there are no exposed wires.
- Calibrate the system
Follow the manufacturer's calibration instructions to ensure the CCFI610 is functioning correctly. Adjust settings as necessary based on the specific application requirements.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.