The nVent CCFI14 (SKU: CCFI14) is a modular cable entry gland plate designed for tool-free installation into industrial enclosures. Constructed from halogen-free Polyamide with a black finish, this 81x70x20mm plate features ten openings for CCG cable entry grommets (sold separately), enabling flexible cable routing for pre-assembled or unassembled cables with or without connectors. The snap-in fastening system accommodates wall thicknesses from 1.4 to 2 mm, reducing installation time by eliminating tools. When paired with compatible grommets and cables, the CCFI14 achieves IP65 protection against dust and water ingress, while its integrated NBR/EPDM seal ensures environmental resistance. Operating from -30°C to +90°C with a V-0 flammability rating per UL94, this gland plate is ideal for control cabinets, automation systems, and machinery enclosures. Strain relief is achieved via simple cable ties, and dummy grommets must be used in unused openings to maintain IP ratings. Trust nVent for reliable, compliant cable management in demanding industrial environments.
  • Delivery: Frame + Inlay for CCFGS
  • Description: CCFI cable entry is quick and easy to assemble. It is made of a sturdy, glass-fiber reinforced plastic. With an IP66 rating, the foam seal helps ensure an optimal seal. The system comes prepared with inlays to fit small grommets (CCFGS). CCFG
  • Finish: Black
  • Flammability: UL94 V-0
  • Material: Polyamide 6.6 / TPE
  • Pack quantity: 1pc
  • Protection: IP66, NEMA 1, 4x, 12 (Indoor use only)
  • Temperature resistance: -40°C to +120°C
  • Grommets sold separately
  • Alternate inlays/dividers for different grommet configurations sold separately

Specifications

Application
Controls and Drives; Corrosive Environments
Cable Entry Quantity
6
Color
Black
Cutout Size
46 x 46 mm
Cutout Size
1.81 x 1.81 in
Depth
0.77 in
Depth
19.6 mm
Finish
Untreated
Height
3.19
Height
81
Height
81 mm
Material
Plastic
Operating Temperature
-40-248 °F
Operating Temperature
-40-120 °C
Product Family
Cable Manager
Protection Rating
NEMA Type 1
Type
Cable Entry Systems
Weight
0.142 lb
Weight
0.1 kg
Width
70 mm
Width
2.76
Width
70
Works With
NEMA
Package Dimensions (L x W x H)
5 IN x 4 IN x 1 IN
Package Dimensions (L x W x H)
12.7 cm x 10.16 cm x 2.54 cm
Package Weight (Imperial)
0.140 L
Package Weight (Metric)
0.064 kg
Cable Entry Gld Plt Connected Inside, CCFI, 106x70x20mm, Blk, Plastic

CCFI610

Cable Entry Gld Plt Connected Inside, CCFI, 106x70x20mm, Blk, Plastic
Bushing for Strain Relief Cord Connectors with 90 Degree Bend 1-1/4 Inch to 1-1/2 Inch

053-71411-7

Bushing for Strain Relief Cord Connectors with 90 Degree Bend 1-1/4 Inch to 1-1/2 Inch
The T-70 Power Rated Raceway Cover is designed to snap on to the base to create a tamper resistant cable routing solution along perimeter walls. It is 8 ft and Off White

T70CIW8

The T-70 Power Rated Raceway Cover is designed to snap on to the base to create a tamper resistant cable routing solution along perimeter walls. It is 8 ft and Off White

How to Install the CCFI14 Cable Entry System

This guide provides step-by-step instructions for installing the CCFI14 cable entry system, ensuring proper mounting and sealing.

Estimated time: 30m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

M5 stainless steel screws, Gland plate seal

  1. Prepare the installation area

    Ensure the installation area is clean and free of debris. Verify that the enclosure is suitable for the CCFI14 installation.

  2. Mount the gland plate

    Align the gland plate with the cutout dimensions specified for the CCFI14. Secure it using four M5 stainless steel screws, ensuring they are tightened to a torque of 3 Nm (26 in-lbs).

  3. Insert the seal

    Push the seal all the way into the gland plate to ensure a proper fit. This will help maintain the integrity of the enclosure against environmental factors.

  4. Verify installation

    Check that the gland plate is securely mounted and that the seal is properly inserted. Use a multimeter to ensure there are no electrical faults in the installation.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.