The nVent CCC48 Stainless HMI Enclosure (SKU: CCC48S404016) is engineered for demanding industrial environments where superior corrosion resistance and robust protection for Human-Machine Interface (HMI) components are paramount. Constructed from high-quality Brushed Stainless Steel 304, this enclosure offers exceptional durability and a clean aesthetic, making it a preferred choice for industries such as food and beverage processing, pharmaceuticals, and chemical manufacturing. Its Type 4X rating ensures protection against water ingress, dust, and corrosion, vital for washdown applications and environments exposed to harsh chemicals. Designed for versatility, the CCC48 enclosure features a cutout specifically for HMI integration, simplifying the mounting of control panels and displays. The intelligent design allows for flexible mounting options, with the ability to attach to various support arm systems from either the top or bottom position. This adaptability ensures seamless integration into existing or new production lines, optimizing workspace and operator accessibility. For internal equipment mounting, an optional mounting plate can be installed, providing a secure platform for sensitive electronics and control gear on the rear of the enclosure. The rear of the enclosure is equipped with integrated pins, facilitating straightforward installation and removal of the mounting plate or other internal components. This nVent enclosure series is renowned for its reliability and performance. The 400x400x160mm dimensions provide ample space for a range of HMI devices and associated wiring, while maintaining a compact footprint. The brushed finish not only enhances its resistance to fingerprints and minor abrasions but also contributes to its hygienic properties, crucial for sanitary applications. Professionals trust nVent for their commitment to quality and innovation in enclosure solutions, ensuring that critical control equipment is protected, operational, and easily accessible for maintenance and operation. The CCC48 series exemplifies this dedication, offering a robust, reliable, and compliant solution for your most critical HMI applications.
  • Durable Brushed Stainless Steel 304 construction for superior corrosion resistance.
  • Type 4X / NEMA 4X rating provides protection against water, dust, and corrosive agents.
  • Optimized 400x400x160mm dimensions for HMI integration and component mounting.
  • Versatile top/bottom mounting capability for seamless integration with support arm systems.
  • Optional mounting plate and rear pins for easy internal equipment installation.
  • Stainless steel safety latch mounted at side, away from protected space
  • Can be mounted from top or bottom

Specifications

Application
Corrosive Environments; Controls and Drives
Color
Unpainted
Depth
6.3 in
Door Clear Space
12.59 x 11.42 in
Finish
Brushed
Height
15.75 in
IP Rating
IP66
Material
Stainless Steel 304
Modification Services
Yes
Mounting Plate
CCCP4040
NEMA Rating
4X Watertight, corrosion-resistant
Product Family
Compact
Protection Rating
NEMA Type 12
Size
400x400x160mm
Thickness
1.5 mm
Type
HMI Enclosure Systems
Type Number
Type 4X
Use With Pendant Arm System
CS480
Weight
19.9 lb
Width
15.75 in
Package Dimensions (L x W x H)
16.8 IN x 16.2 IN x 8.5 IN
Package Dimensions (L x W x H)
42.672 cm x 41.148 cm x 21.59 cm
Package Weight (Imperial)
19.900 L
Package Weight (Metric)
9.027 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Prepare the Enclosure for CCC48S404016 Installation

This guide outlines essential enclosure preparation steps, including door grounding, removal, and cable management, which are crucial before installing devices like the CCC48S404016.

Estimated time: 30m

Tools needed:

Screwdriver, Wire strippers

Supplies needed:

Grounding wire, Cable ties

  1. Ground the Enclosure Door

    Connect a suitable grounding wire from the enclosure door to the designated ground point on the enclosure frame. Ensure a secure connection for electrical safety.

  2. Remove the Enclosure Door (Optional)

    If necessary for installation or access, carefully remove the enclosure door. Follow the indicated sequence: unfasten any securing clips or screws, lift the door from its hinges, and set it aside safely.

  3. Organize Internal Cabling

    Route and secure all internal cables, ensuring they are neatly organized and do not obstruct components or door closure. Use cable management accessories as needed.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.