nVent CCC48S303513 - Stainless HMI Enclosure CCC48 Cutout Type 4X, 300x350x130mm, Brushed, SS304
nVent

CCC48S303513

UPC: 783510460198


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent CCC48S303513 is a robust Stainless HMI Enclosure designed for demanding industrial applications. Constructed from SS304 stainless steel with a brushed finish, this enclosure offers superior resistance to corrosion, staining, and microbial growth, making it ideal for environments found in food & beverage, pharmaceutical, and chemical processing industries. It features a Type 4X rating, equivalent to IP66/IP69K, ensuring protection against water ingress, dust, and corrosive substances, and can withstand high-pressure washdowns and harsh cleaning agents. The enclosure measures 300x350x130mm and includes a cutout for seamless mounting to support arm systems, with additional top/bottom mounting options. Integrated rear pins simplify installation, and an optional internal mounting plate is available for secure component mounting. The brushed surface minimizes glare, enhancing HMI screen visibility. Manufactured in the USA, this enclosure provides reliable protection for your Human Machine Interface components.
  • SS304 Stainless Steel construction for corrosion resistance
  • Type 4X rating (IP66/IP69K equivalent) for protection against water and dust
  • Brushed finish minimizes glare for improved HMI screen visibility
  • Cutout for seamless mounting to support arm systems
  • Dimensions: 300x350x130mm
  • Integrated rear pins simplify enclosure mounting and installation.
  • Ideal for food & beverage, pharmaceutical, and chemical processing industries.
  • Manufactured in the USA for assured quality and reliability.

Specifications

Application
Controls and Drives; Corrosive Environments
Color
Unpainted
Color
Brushed
Depth
5.12 in
Door Clear Space
8.66 x 9.45 in
Finish
Brushed
Height
11.81 in
Ip Rating
IP4X
IP Rating
IP66
Material
Stainless Steel 304
Material
SS304
Modification Services
Yes
Mounting Plate
CCCP3035
Mounting Type
CS480 Mounting
NEMA Rating
4X Watertight, corrosion-resistant
Nema Rating
Type 4X
Product Family
Compact
Protection Rating
NEMA Type 12
Series
CCC48
Size
300x350x130mm
Thickness
1.5 mm
Type
HMI Enclosure Systems
Type Number
Type 4X
Use With Pendant Arm System
CS480
Weight
13.7 lb
Width
13.78 in
Package Dimensions (L x W x H)
16.3 IN x 16 IN x 6.6 IN
Package Dimensions (L x W x H)
41.402 cm x 40.64 cm x 16.764 cm
Package Weight (Imperial)
13.700 L
Package Weight (Metric)
6.214 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Prepare and Maintain the CC480/CC600 Enclosure

This guide provides essential procedures for the initial assembly, door grounding, door removal, and cable management for the CC480/CC600 enclosure.

Estimated time: 30m

Tools needed:

Screwdriver

Supplies needed:

Mounting hardware, Grounding wire

  1. Assemble Enclosure Components

    Perform the initial assembly of the enclosure components. Refer to the provided diagrams for the correct placement and use of parts, including those indicated by '1' and '2' and their quantities.

  2. Ground the Enclosure Door

    Ensure electrical safety by properly grounding the enclosure door. Connect a suitable grounding wire as indicated in the 'Door Grounding' section of the documentation.

  3. Remove the Enclosure Door

    If access is required for installation or maintenance, carefully remove the enclosure door by following the 'Door Removal' procedure outlined in the documentation.

  4. Manage Internal Cables

    Implement effective cable management within the enclosure to ensure organized wiring and proper airflow. Refer to the 'Cable Management' section for guidance.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.