nVent AU8418EPTSS Universal Free-Stand Formed End Plate, 84.13x18.11x2.50, Brushed, Stainless 304
UPC: 783510389857
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Universal Free-Stand End plate is used to seal open side(s) of nVent HOFFMAN Universal Free-stand Enclosures.
- The 2.50-inch deep End Plate allows extra wiring space and is Type 4X, 4, 12, 3R and IP66 rated
- Gasket and mounting bolts are included
- Dimensions: 84.13 x 18.11 x 2.50 inches, providing ample wiring space.
- Includes pre-installed gasket and mounting bolts for simplified installation.
Specifications
Application | Arc Flash Safety;Controls and Drives;Power Distribution |
Application | Power Distribution; Arc Flash Safety; Controls and Drives |
Cable Entry | No |
Color | None |
Color | Brushed |
Connection | No |
Depth | 2.5 in |
Depth | 64 mm |
Depth | 64 |
Finish | Brushed |
Height | 84.13 in |
Height | 2,137 mm |
Height | 2,137 |
Insulation | No |
Insulation | False |
IP Rating | IP66 |
Material | Stainless 304 |
Material | Stainless Steel 304 |
Material Quality | Stainless Steel 304 |
Material Quality | Stainless steel V2A |
NEMA Rating | 12;4;4X |
NEMA Rating | 4X, 4, 12, 3R |
NEMA Rating | Type 4X, 4, 12, 3R |
Number Of Outlet | 0 |
Size | 84.13 x 18.11 x 2.5 inch |
Thickness | 1.9 mm |
Thickness | 14 ga |
Thickness | 51.40mm (2.024") |
Type | Other Accessories |
Weight | 60 lb |
Width | 18.11 in |
Width | 460 mm |
Works With | NEMA |
Package Dimensions (L x W x H) | 87.25 IN x 21 IN x 4 IN |
Package Dimensions (L x W x H) | 221.615 cm x 53.34 cm x 10.16 cm |
Package Weight (Imperial) | 60.000 L |
Package Weight (Metric) | 27.216 kg |

BX4
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, BlackFrequently Asked Questions
What is the purpose of the AU8418EPTSS End Plate?
The End Plate is used to seal the open side(s) of nVent HOFFMAN Universal Free-stand Enclosures.
What are the NEMA and IP ratings for this end plate?
The End Plate is Type 4X, 4, 12, 3R and IP66 rated.
What material is the AU8418EPTSS End Plate made of?
The End Plate is constructed from Stainless Steel 304.
What are the dimensions of the AU8418EPTSS End Plate?
The End Plate measures 84.13 inches in height, 18.11 inches in width, and 2.5 inches in depth.
Does the AU8418EPTSS End Plate include mounting hardware?
Yes, a gasket and mounting bolts are included with the End Plate.
What is the thickness of the end plate material?
The material thickness of the end plate is 14ga.
What is the weight of the AU8418EPTSS End Plate?
The End Plate weighs 60lb.
What is the finish of the AU8418EPTSS End Plate?
The End Plate has a brushed finish.
Where can I find installation instructions for nVent products?
Installation sheets are available at www.nvent.com or from your nVent customer service representative.
What are the consequences of improper installation of nVent products?
Improper installation can lead to product malfunction, property damage, serious injury, death, and void the warranty.
How to Install the AU8418EPTSS Controller
This guide provides step-by-step instructions for installing and configuring the AU8418EPTSS Controller on a DIN rail.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Mount the controller
Secure the AU8418EPTSS controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.
- Connect the wiring
Use terminal connectors to connect the power supply and input/output wires to the designated terminals on the controller. Ensure all connections are tight and secure.
- Verify the installation
Power on the controller and use a multimeter to check the voltage at the input terminals. Confirm that the readings are within the specified range.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.