Contact for Pricing
Overview
- Material: AISI 304L / AISI 316L pre-grained stainless steel. Body: 1.5 mm. Door for AISI 304L: 1.5 mm / 2 mm for enclosures with a height or width of 600 mm or greater. Door for AISI 316L: 2 mm. Mounting plate: 2 mm galvanized steel.
- Body: Folded and seam welded. For ease of installation, each back corner of the enclosure is laser-marked to precisely indicate where to drill holes and affix AWS wall mounting brackets.
- Door: Corner formed in one piece. Surface mounted, with 130° opening. Concealed AISI 304 stainless steel hinges with captive pin. Can be mounted to allow left or right hand opening. Sealing is ensured by an injected polyurethane gasket. For AISI 316L, sea
- Lock: nVent HOFFMAN customized zamak double-bit 3 mm lock, with 90° movement and anti-vibration mechanism. Two locks for 600 mm high to 800 mm high enclosures. Espagnolette three point locking or 3 locks for 1000 mm high enclosures and above. Stainless st
- Mounting plate: The mounting plate is marked vertically at 10 mm intervals, for easy horizontal positioning of equipment. On the top and bottom there are holes to facilitate cable fixing. Fixed onto M8 press welded studs to the rear of the enclosure. All
- Cable access: No gland plate openings as standard, to maximise sealing and cleanliness.
- Protection: Corresponds with IP 66, TYPE 4X, 12, IK 10.
- Finish: 400 pre-grained stainless steel.
- Delivery: Enclosure with door, mounting plate, plastic double-bit 3 mm key, and mounting accessories. Metallic key, for height 1000 mm and above.
- Additional information: For outdoor environments, exposed to precipitation, the use of a rain hood is advised. Also in environments known for quick temperature changes, consideration to condensation should be taken. Please see the thermal management secti
Specifications
Application | Corrosive Environments; Hazardous Environments; Factory Automation and Process Control |
Body Thickness | 16 ga |
Body Thickness | 1.5 mm |
Cable Entry | No |
Color | Brushed Stainless |
Color | Unpainted |
Connection | No |
Construction | Body: 16 gauge Door: 16 gauge |
Cubic Capacity | 791 Cu-in |
Depth | 150 mm |
Depth | 5.91 in |
Door Thickness | 1.5 mm |
Door Thickness | 16 ga |
Finish | Brushed |
Height | 9.45 in |
Height | 240 mm |
Insulation | No |
IP Rating | IP66 |
Knockouts | No |
Latch Quantity | 1 |
Material | AISI 304 Stainless Steel |
Material | Stainless Steel 304 |
Material | Stainless 304 |
Max Mounting Depth | 5.19 in |
Max Mounting Depth | 132 mm |
Mounting | Wall Mounted |
Mounting Type | Wall-mounted |
Mounting Type | Wall mounted |
Number of Outlet | 1 |
Protection Rating | NEMA Type 12 |
Series | ASR |
Size | 240x360x150 mm |
Size | 9.45 x 14.17 x 5.91 inch |
Type | Stainless Steel Wall Mounted Industrial Enclosures |
Weight | 4.75 kg |
Weight | 10.47 lb |
Width | 14.17 in |
Width | 360 mm |
Package Dimensions (L x W x H) | 14.55 IN x 9.82 IN x 14.8 IN |
Package Dimensions (L x W x H) | 36.957 cm x 24.9428 cm x 37.592 cm |
Package Weight (Imperial) | 11.400 L |
Package Weight (Metric) | 5.171 kg |

BX4
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, BlackFrequently Asked Questions
What are the dimensions of the ASR0243615 enclosure?
The enclosure has dimensions of 9.45 inches in height, 14.17 inches in width, and 5.91 inches in depth.
What material is the ASR0243615 enclosure made from?
The enclosure is constructed from Stainless Steel 304 with a brushed finish.
What is the protection degree of this enclosure?
The enclosure has an IP 66 protection degree and meets NEMA/EEMAC Type 4, 4X, 12 standards.
What type of gasket is used for sealing?
The enclosure uses an injected polyurethane gasket for sealing.
What is the thickness of the enclosure body and door?
The body thickness is 16 gauge, and the door thickness is also 16 gauge.
What type of lock does the enclosure feature?
It features a customized zamak double-bit 3 mm lock with a 90° movement and anti-vibration mechanism.
How is the mounting plate positioned?
The mounting plate is marked vertically at 10 mm intervals for easy positioning and can be adjusted with the AMG accessory.
Are there standard gland plate openings for cable access?
No, there are no gland plate openings as standard to maximize sealing and cleanliness.
What industry standards does this enclosure comply with?
It complies with UL 508A, cUL, NEMA/EEMAC, CSA, and IEC 62208 standards.
What is the maximum mounting depth inside the enclosure?
The maximum mounting depth for equipment inside the enclosure is 5.19 inches.
ASR0243615 Installation Safety Considerations
This guide outlines critical safety warnings for ASR0243615 installation. The provided document contains only safety information and no specific installation or setup steps.
Estimated time: 5m
Supplies needed:
Floor plate (if applicable)
- Prepare Mounting Surface for Combustible Materials
WARNING: When mounting ASR0243615 on or over a combustible surface, a floor plate of at least 1.43 mm galvanized or 1.6 mm uncoated steel extended at least 150 mm beyond the equipment on all sides must be installed to prevent fire hazards.
- Maintain Enclosure Environmental Integrity
WARNING: To maintain the environmental integrity of the ASR0243615 enclosure, ensure that any devices used to close openings in a customized enclosure have the same environmental ratings as the original enclosure.
- Review All Safety Documentation
Always review all available safety and installation documentation for ASR0243615 before proceeding with any physical installation or setup to ensure compliance with all applicable standards and safe operation.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.