nVent AN3325PL - ARIA Flat Opaque Cover Type 4X, 32.87x25.00x11.81, Lt Gray, Fiberglass, PL
nVent

AN3325PL

UPC: 635394000505


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ARIA Flat Opaque Cover Type 4X (SKU: AN3325PL) is a fiberglass enclosure designed for harsh industrial environments requiring Type 4X protection. This enclosure measures 32.87x25.00x11.81 inches (835x635x300 mm) and features a lightweight yet durable fiberglass construction with a flat opaque cover for aesthetic and functional performance. It meets IP66 and Type 4X ratings for protection against dust, water ingress, and corrosion, making it suitable for outdoor and industrial applications exposed to moisture, chemicals, or particulate matter. Compliance with UL 508A and cUL CSA C22.2 No. 94 standards ensures safety for electrical components. The enclosure includes integral mounting brackets for secure installation and Type 316 stainless steel latches for padlockable access. The light gray finish provides UV resistance, reducing degradation in sunlight-exposed environments. Ideal for insulated electrical junction boxes, terminal wiring enclosures, instrument housings, and control panels, this enclosure excels in chemical processing plants, water treatment facilities, food and beverage production, and marine applications. Its fiberglass material prevents rust and corrosion in high-humidity or chemically aggressive conditions, ensuring long-term durability.
  • Enclosures are maintenance free and corrosion resistant
  • Bases and covers are made from hot compression molded halogen free, self extinguishing fiberglass reinforced polyester (FRP) that can withstand continuous temperatures up to 158°F (-50°C to 70°C) and momentary exposure to 302°F (150°C)
  • 4 threaded studs are molded in for attachment of mounting plates and frames.
  • All enclosures can be easily modified to customer specifications
  • UL 508A listed and cUL CSA C22.2 No. 94 certified

Specifications

Application
Corrosive Environments; Controls and Drives
Color
Light Gray
Color Code
RAL 7035
Depth
300 mm
Depth
11.81 in
Finish
Smooth Matte
Height
32.87 in
Height
835 mm
Material
Fiberglass
Product Family
ARIA
Protection Rating
NEMA Type 3
Type
Fiberglass and Thermoplastic Wall Mounted Industrial Enclosures
Weight
36 lb
Width
25 IN
Width
635 mm
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the AFP4032N Enclosure

This guide provides step-by-step instructions for installing and setting up the AFP4032N enclosure, ensuring proper mounting, wiring, and initial configuration.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the enclosure

    Secure the AFP4032N enclosure to the designated mounting surface using the provided mounting screws. Ensure the enclosure is level and firmly attached.

  2. Connect the wiring

    Strip the ends of the wires and connect them to the appropriate terminal connectors inside the enclosure. Ensure all connections are tight and secure to prevent any electrical issues.

  3. Verify electrical connections

    Use a multimeter to check the continuity of the connections. Ensure that all connections are functioning correctly before proceeding with the setup.

  4. Configure the enclosure settings

    Follow the manufacturer's instructions to configure any necessary settings on the AFP4032N enclosure. This may include setting up communication protocols or adjusting operational parameters.

  5. Calibrate the enclosure

    Perform any required calibration procedures as specified in the documentation to ensure the enclosure operates within the desired parameters.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.