Overview

The nVent ADR1001030-316 Double Door Enclosure is a premium-grade stainless steel solution engineered for demanding industrial environments where space efficiency, durability, and protection are critical. Designed by nVent, a global leader in thermal management and electrical protection solutions, this enclosure combines robust construction with intelligent design to meet the rigorous demands of modern industrial applications. With a brushed stainless steel 316 finish, the ADR1001030-316 offers exceptional corrosion resistance, making it ideal for harsh or hygienic environments such as food and beverage processing, pharmaceutical manufacturing, chemical handling, and marine applications. Its double-door configuration ensures optimal access to internal components while minimizing space intrusion—critical in confined installation areas where a single door would obstruct workflow or maintenance access. The enclosure’s IP66 rating provides superior protection against dust ingress and high-pressure water jets, ensuring reliable operation even in washdown environments or outdoor installations exposed to the elements. The load-bearing capacity is distributed across two doors, enhancing structural integrity and ease of operation under heavy component loads. This design also supports better cable management and thermal dissipation, reducing the risk of overheating in densely packed control or instrumentation systems. Professionals in industries such as water treatment, oil and gas, and power distribution rely on nVent’s ADR series for its proven performance and compliance with international safety standards. Installation is straightforward with wall-mounting provisions, and the brushed finish resists fingerprints and surface damage, maintaining a professional appearance in cleanroom or visible installation zones. Backed by nVent’s reputation for innovation and reliability, the ADR1001030-316 is not just an enclosure—it’s a long-term investment in system uptime, safety, and operational efficiency. Whether deployed in a food-grade facility requiring frequent sanitation or a coastal industrial site facing salt spray exposure, this enclosure delivers uncompromising protection and accessibility.
  • Material: AISI 304L / AISI 316L pre-grained stainless steel. Body: 1.5 mm. Door: 2 mm. Mounting plate: 2.5 mm galvanized steel.
  • Body: Folded and seam welded. For ease of installation, each back corner of the enclosure is laser-marked to precisely indicate where to drill holes and affix AWS wall mounting brackets.
  • Door: Corner formed in one piece. Surface mounted, with 130° opening. Concealed AISI 304 stainless steel hinges with captive pin. Sealing is ensured by an injected polyurethane gasket. For AISI 316L, sealing is ensured by an injected silicone gasket. Inne
  • Lock: nVent HOFFMAN customized zamak double-bit 3 mm lock, with 90° movement and anti-vibration mechanism. Espagnolette three point locking. Stainless steel lock and other versions are available as accessories.
  • Mounting plate: The mounting plate is marked vertically at 10 mm intervals, for easy horizontal positioning of equipment. On the top and bottom there are holes to facilitate cable fixing. Fixed onto M8 press welded studs to the rear of the enclosure. All
  • Cable access: No gland plate openings as standard, to maximise sealing and cleanliness.
  • Finish: 400 pre-grained stainless steel.
  • Protection: Corresponds with IP 55, TYPE 12, IK 10.
  • Delivery: Enclosure with door, mounting plate, metallic key and mounting accessories.
  • Additional information: For outdoor environments exposed to precipitation, the use of a rain hood is advised. Also in environments known for quick temperature changes, consideration to condensation should be taken. Please see the thermal management sectio

Specifications

Application
Hazardous Environments; Factory Automation and Process Control; Corrosive Environments
Application
Corrosive Environments; Factory Automation and Process Control; Hazardous Environments
Body Thickness
1.5 mm
Body Thickness
16 ga
Cable Entry
No
Color
Unpainted
Color
Brushed stainless steel
Connection
No
Construction
Body: 16 gauge Door: 14 gauge
Cubic Capacity
18307 Cu-in
Depth
300 mm
Depth
11.81 in
Door Thickness
2 mm
Door Thickness
14 ga
Finish
Brushed
Height
1,000 mm
Height
39.37 in
Insulation
No
IP Rating
IP66
IP Rating
IP55
Knockouts
No
Latch Quantity
1
Material
Stainless 316
Material
Stainless Steel 316
Max Mounting Depth
282 mm
Max Mounting Depth
11.1 in
Mounting
Wall Mounted
Mounting Type
Wall-mounted
Number Of Outlet
1
Protection Rating
NEMA Type 12
Series
ADR
Size
1000x1000x300mm
Size
39.37 x 39.37 x 11.81 inch
Type
Stainless Steel Wall Mounted Industrial Enclosures
Weight
70 kg
Weight
154.35 lb
Width
39.37 in
Width
1,000 mm
Package Dimensions (L x W x H)
39.75 IN x 39.75 IN x 12.44 IN
Package Dimensions (L x W x H)
100.965 cm x 100.965 cm x 31.5976 cm
Package Weight (Imperial)
154.350 L
Package Weight (Metric)
70.013 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Prepare for ADR1001030-316 Installation

This guide outlines critical safety warnings and preparatory steps for mounting the ADR1001030-316, focusing on requirements for combustible surfaces and maintaining enclosure integrity.

Estimated time: 5m

  1. Understand Mounting Surface Requirements

    Before mounting the ADR1001030-316, understand that if it is to be installed on or over a combustible surface, a floor plate is required. This plate must be at least 1.43 mm galvanized or 1.6 mm uncoated steel.

  2. Install Required Floor Plate

    If mounting on a combustible surface, install a floor plate that extends at least 150 mm beyond the equipment on all sides. This plate must meet the specified material and thickness requirements (1.43 mm galvanized or 1.6 mm uncoated steel).

  3. Maintain Enclosure Environmental Integrity

    When customizing the enclosure or closing openings, ensure that any devices used have the same environmental ratings as the ADR1001030-316. This is crucial for maintaining the environmental integrity of the enclosure.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.