nVent A90XM7818FTCLPG - Heavy-Duty Disconnect Gray Inside LP Type 12, 90.12x78.50x18.12, Gray, Steel
nVent

A90XM7818FTCLPG

UPC: 783510257071


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent Heavy-Duty Disconnect Enclosure (SKU: A90XM7818FTCLPG) is engineered for robust protection of electrical disconnect switches and control equipment in demanding industrial environments. Manufactured by nVent, a trusted leader in electrical enclosure solutions, this enclosure provides superior durability and reliability. Its construction from heavy-gauge steel, finished in a standard industrial gray, ensures resistance to corrosion and physical impact, making it ideal for applications where harsh conditions are prevalent. Designed to meet Type 12 NEMA standards, this enclosure offers excellent protection against dust, dirt, and dripping water, safeguarding sensitive electrical components from contamination and operational failure. The generous dimensions of 90.12 inches in height, 78.50 inches in width, and 18.12 inches in depth accommodate a wide range of disconnect switch configurations and associated control devices. This specific model, featuring a "LP Type" designation, suggests a low-profile design optimized for space-constrained installations without compromising on protection or accessibility. Key features of the nVent Heavy-Duty Disconnect Enclosure include: * **Robust Construction:** Fabricated from heavy-duty steel for maximum strength and longevity. * **Type 12 Protection:** Offers superior ingress protection against dust, dirt, and water. * **Generous Dimensions:** Ample internal space (90.12" x 78.50" x 18.12") for various electrical components. * **Corrosion Resistance:** Industrial gray finish provides a durable barrier against environmental degradation. * **Manufacturer Reliability:** Backed by the quality and expertise of nVent. This disconnect enclosure is a cost-effective and straightforward solution for protecting critical electrical infrastructure. Its simple yet effective design minimizes installation complexity and maintenance requirements. While this specific SKU is listed as "Disc. Encl. 2Dr FS wo panel," indicating a two-door configuration without an internal panel, nVent offers a comprehensive range of accessories and panel options to customize the enclosure to precise application needs. The flexibility to order with one to six doors (as per the general product line description) allows for scalability and adaptation to diverse project scopes, from single-machine control to large-scale plant automation. Typical applications for this heavy-duty disconnect enclosure span across numerous industries, including manufacturing, food and beverage processing, chemical plants, water and wastewater treatment facilities, and any sector where reliable electrical protection is paramount. It serves as a vital component in ensuring operational continuity and personnel safety by isolating electrical circuits during maintenance or in emergency situations. The US country of origin underscores a commitment to quality manufacturing standards. When selecting an enclosure, professionals prioritize factors such as NEMA/IP ratings, material durability, internal space, and ease of access for installation and servicing. The nVent A90XM7818FTCLPG meets these critical requirements, offering a dependable solution for safeguarding electrical systems against the rigors of industrial operation.
  • Seams continuously welded and ground smooth
  • Body stiffeners in larger enclosures for extra rigidity
  • Body flange trough excludes liquids and contaminants
  • Heavy-duty lifting eyes anchor into reinforced top
  • Removable centerposts permit easy panel installation
  • Concealed, easy-to-remove hinges
  • Heavy-duty 3-point latching mechanism operated by padlocking handle on all doors
  • Panel supports
  • Data pocket is high-impact thermoplastic
  • Oil-resistant gasket

Specifications

Application
Arc Flash Safety;Controls and Drives;Power Distribution
Application
Power Distribution; Arc Flash Safety; Controls and Drives
Color
Gray
Depth
460 mm
Depth
18.12
Depth
460
Exterior Color
Gray
Exterior Color Code
ANSI 61
Finish
Powder Coated
Height
2,289 mm
Height
90.12
Height
2,289
Interior Color
Gray
IP Rating
IP55
Material
Mild Steel
Material
Steel
Modification Services
Yes
NEMA Rating
12
Nema Rating
Type 12
NEMA Rating
12 Indoor, dust-resistant
Panel Included
No
Protection Rating
NEMA Type 12
Series
Heavy-Duty Disconnect Gray Inside LP
Size
90.12x78.50x18.12 inches
Size
90.12x78.50x18.12
Size
90.12x78.50x18.12 in
Stiffener Locations
610 mm
Stiffener Locations
24 in
Thickness
11 ga
Thickness
3.04 mm
Thickness
51.40mm (2.024")
Type
Mild Steel Freestanding Industrial Disconnect Enclosures
Type Number
Type 12
Weight
903 lb
Width
1,994 mm
Width
78.5
Width
1,994
With or Without Panel
Without
Package Dimensions (L x W x H)
84 IN x 36 IN x 100 IN
Package Dimensions (L x W x H)
213.36 cm x 91.44 cm x 254 cm
Package Weight (Imperial)
903.000 L
Package Weight (Metric)
409.601 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the WS74XM7524SS Enclosure

This guide provides step-by-step instructions for safely installing the WS74XM7524SS enclosure, ensuring proper handling and setup.

Estimated time: 1h

Tools needed:

Forklift, Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, 3000 lb-rated chain or strap

  1. Prepare the installation area

    Clear the installation route of all obstructions and ensure that workers are at a safe distance, more than the overall height of the enclosure.

  2. Secure the enclosure for transport

    Using a forklift, insert a 3000 lb-rated chain or strap through the eye bolts on top of the enclosure and securely fasten it to the forklift mast. Ensure sufficient tension to prevent tipping.

  3. Lift and position the enclosure

    Carefully lift the enclosure using the forklift, ensuring it is clear of the ground. Position the enclosure at the desired installation location.

  4. Mount the enclosure

    Secure the enclosure to the mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  5. Connect electrical components

    Use wire strippers to prepare the wires and connect them to the terminal connectors as per the wiring diagram provided. Verify connections with a multimeter.

  6. Calibrate the enclosure

    Follow the manufacturer's instructions to perform any necessary calibration of the enclosure's components to ensure proper functionality.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.