Authorized nVent Distributor
nVent A90XM4EW24FTCG - Heavy-Duty Disconnect Gray Inside Type 12, 90.12x158.00x24.12, Gray, Steel

nVent A90XM4EW24FTCG Heavy-Duty Disconnect Gray Inside Type 12, 90.12x158.00x24.12, Gray, Steel

UPC: 783510257422


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent **A90XM4EW24FTCG** Heavy-Duty Disconnect Gray Inside Type 12 Enclosure is a robust, cost-effective solution designed for demanding industrial environments where reliable power distribution and equipment protection are critical. Engineered by nVent, a global leader in thermal management and electrical solutions, this enclosure combines durability, flexibility, and compliance with industry standards to deliver unmatched performance in harsh conditions. With its **90.12 x 158.00 x 24.12 mm** gray steel construction, this Type 12 enclosure is built to withstand dust, dirt, and non-hazardous liquids while providing secure housing for disconnect switches, circuit breakers, and other electrical components. This heavy-duty enclosure is ideal for applications requiring **four doors** for enhanced accessibility and organization. The modular design allows for customization with one to six doors, making it adaptable to a wide range of electrical distribution needs—from manufacturing plants and commercial buildings to data centers and utility facilities. Professionals in industries such as **automotive, aerospace, food processing, and pharmaceuticals** rely on Type 12 enclosures to protect sensitive equipment from environmental contaminants while ensuring compliance with **NEMA 12** and **IP54** standards for ingress protection. Key features of the nVent A90XM4EW24FTCG include: - **Heavy-duty steel construction** for superior durability and impact resistance. - **Gray powder-coated finish** for corrosion resistance and aesthetic consistency. - **Modular door configuration** (1-6 doors) to accommodate diverse installation requirements. - **Type 12 rating** for protection against dust, dirt, and non-hazardous liquids. - **Easy installation and maintenance** with pre-drilled mounting holes and accessible interior space. Installation is straightforward, with pre-engineered mounting points and clear labeling for efficient wiring and component placement. The enclosure’s **compact yet spacious interior** (24.12 mm depth) ensures compatibility with standard disconnect switches and control panels, while its **Type 12 compliance** makes it suitable for indoor environments where cleanliness and equipment longevity are priorities. Whether used in **motor control centers, HVAC systems, or industrial machinery**, this enclosure provides a reliable barrier against contaminants while simplifying access for maintenance and upgrades. nVent’s reputation for innovation and quality ensures that the A90XM4EW24FTCG meets the rigorous demands of modern industrial applications. As part of nVent’s comprehensive portfolio of electrical solutions, this enclosure reflects the company’s commitment to **safety, performance, and sustainability**. Trusted by engineers and facility managers worldwide, nVent enclosures like this one are a cornerstone of efficient and compliant electrical infrastructure. For projects requiring a **heavy-duty, cost-effective, and versatile disconnect enclosure**, the nVent A90XM4EW24FTCG delivers uncompromising protection and functionality.
  • Seams continuously welded and ground smooth
  • Body stiffeners in larger enclosures for extra rigidity
  • Body flange trough excludes liquids and contaminants
  • Heavy-duty lifting eyes anchor into reinforced top
  • Removable centerposts permit easy panel installation
  • Concealed, easy-to-remove hinges
  • Heavy-duty 3-point latching mechanism operated by padlocking handle on all doors
  • Panel supports
  • Data pocket is high-impact thermoplastic
  • Oil-resistant gasket

Specifications

Application
Arc Flash Safety;Controls and Drives;Power Distribution
Application
Power Distribution; Controls and Drives; Arc Flash Safety
Color
Gray
Color
Grey
Conductive Large Panel
A90PM78G
Depth
24.12 in
Depth
613 mm
Depth
613
Exterior Color
Gray
Exterior Color Code
ANSI 61
Finish
Powder Coated
Height
2,289
Height
2,289 mm
Height
90.12 in
Interior Color
Gray
IP Rating
IP55
Large Painted Panel
A90PM78
Large Panel Quantity
2
Large Panel Size
78.00 x 72.00 in
Large Panel Size
1981 x 1829 mm
Material
Mild Steel
Material
Steel
Modification Services
Yes
NEMA Rating
12
Nema Rating
Type 12
NEMA Rating
12 Indoor, dust-resistant
Panel Included
Yes
Protection Rating
NEMA Type 12
Size
90.12x158.00x24.12 in
Size
90.12x158.00x24.12
Thickness
51.40mm (2.024")
Thickness
11 ga
Thickness
3.04 mm
Type
Mild Steel Freestanding Industrial Disconnect Enclosures
Type Number
Type 12
Weight
2,446 lb
Width
158 in
Width
4,013 mm
Width
4,013
With or Without Panel
With
Package Dimensions (L x W x H)
166 IN x 32 IN x 100 IN
Package Dimensions (L x W x H)
421.64 cm x 81.28 cm x 254 cm
Package Weight (Imperial)
2446.000 L
Package Weight (Metric)
1109.506 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Repaint a Hoffman Enclosure

Guide on preparing and repainting Hoffman enclosures with TGIC polyester powder coating.

Estimated time: 1h

Tools needed:

180 grit sandpaper, 220 or 240 grit sandpaper (optional), Solvent, Paint manufacturer's recommended tools

Supplies needed:

TGIC polyester powder coated Hoffman enclosure, Paint compatible with TGIC polyester powder coating, Primer (if recommended by paint manufacturer)

  1. Prepare the Surface

    Thoroughly sand all enclosure surfaces with 180 grit sandpaper. If sanding marks are objectionable, finish sanding with 220 or 240 grit sandpaper. Wet wipe all surfaces with a solvent to remove any possible contaminants. Consult with your paint manufacturer for proper cure time and hardness prior to testing the paint for adhesion.

  2. Select Appropriate Paint

    Choose a paint that exhibits good adhesion properties over polyester powder. Recommended types include two-component epoxies, some two-component polyurethanes, and alkyd baking enamels. If using alkyd finishes, do not bake at temperatures exceeding 150°F to avoid discoloration.

  3. Apply Paint

    Apply two or three medium to light coats of paint. Allow two to three minutes flash off between coats. Allow paint to cure adequately according to the paint manufacturer's instructions.

  4. Test Adhesion

    After the paint has cured adequately, test the paint for adhesion. Consult with your paint manufacturer for proper cure time and hardness prior to testing.

  5. Test Repainting Process

    NOTICE: Always test the repainting process on an inconspicuous area prior to full application.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.