nVent A864CHSCFGW - Continuous Hinge Window Cover Enclosure 4X, 8x6x4, Light Gray, Fiberglass
nVent

A864CHSCFGW

UPC: 783510312008


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent Continuous Hinge Window Cover Enclosure (SKU: A864CHSCFGW) is a high-performance fiberglass enclosure designed for industrial applications requiring durable, corrosion-resistant protection. Engineered by nVent, a trusted leader in thermal management and electrical protection solutions, this enclosure combines robust construction with practical design features to safeguard sensitive equipment in harsh environments. Measuring 8.00" x 6.00" x 4.00", the enclosure is ideal for housing control panels, instrumentation, or monitoring devices where environmental resistance and accessibility are critical. Key features of the nVent Continuous Hinge Window Cover Enclosure include a continuous hinge that ensures a secure seal and smooth operation, eliminating gaps that could compromise protection. The double latching mechanism provides added security against tampering or accidental opening, making it suitable for applications in industrial plants, manufacturing facilities, or outdoor installations. The light gray fiberglass construction delivers exceptional resistance to corrosion, UV exposure, and chemical attack, ensuring long-term reliability even in coastal, chemical processing, or wastewater treatment environments. Designed for ease of installation and maintenance, this enclosure features corner latches that allow unobstructed access to internal components without the need for tools. The fiberglass material is inherently non-conductive, providing an additional layer of safety for electrical applications while reducing the risk of short circuits or ground faults. Professionals in industries such as oil and gas, utilities, telecommunications, and transportation rely on nVent’s enclosures to protect critical infrastructure from moisture, dust, and mechanical damage. The nVent Continuous Hinge Window Cover Enclosure is part of a broader portfolio of thermal management and protection solutions, reflecting the company’s commitment to innovation and durability. With a reputation for engineering products that meet stringent industry standards, nVent ensures that this enclosure delivers consistent performance in demanding conditions. Whether used in indoor control rooms, outdoor substations, or remote monitoring stations, this enclosure provides a reliable barrier against environmental threats while maintaining operational integrity. For engineers, contractors, and facility managers seeking a dependable solution for housing sensitive equipment, the nVent Continuous Hinge Window Cover Enclosure offers a blend of durability, security, and accessibility. Its fiberglass construction ensures minimal maintenance, while the continuous hinge and double latching system enhance both functionality and longevity. Trusted by professionals worldwide, nVent’s enclosures are a preferred choice for protecting critical assets in some of the most challenging industrial environments.
  • Compression-molded fiberglass has outstanding chemical- and temperature-resistance qualities and exhibits excellent weatherability and physical properties
  • Fiberglass is easily punched, drilled, filed or sawed
  • Gasket assures water-tight and dust-tight seal
  • Polyester mounting brackets and stainless steel attachment screws are provided with each enclosure
  • Scratch-resistant polycarbonate windows are permanently bonded in place
  • Molded-in-place threaded brass inserts and plated steel screws are provided for mounting optional panels and terminal block kits
  • Removable hinged cover attached to body with Type 316 stainless steel hinge pin
  • Screw-cover enclosures are secured with two captivated Type 316 stainless steel slotted cover screws
  • Enclosures with quick-release latches have corrosion-resistant polyester latches located in corners that provide unobstructed access to enclosure
  • Hinge pin and bail are corrosion-resistant Type 316 stainless steel

Specifications

Aluminum Panel
A8P6AL
Application
Controls and Drives;Corrosive Environments
Color
Gray
Color
Grey
Color
Light Gray
Color Code
RAL 7035
Cover Style
Window Screw
Depth
4
Depth
102 mm
Finish
Smooth Matte
Height
8 IN
Height
203 mm
IP Rating
IP66
Material
Fiberglass
Material Quality
Fiberglass
Modification Services
Yes
Mounting
8.94 x 4.00 in
Mounting
Wall Mounting Brackets Available
NEMA Rating
4X Watertight, corrosion-resistant
Nema Rating
Type 4X
NEMA Rating
4X
Overall Dimensions
114 x 88 mm
Overall Dimensions
8.50 x 6.50 in
Panel Size
171 x 124 mm
Panel Size
6.75 x 4.88 in
Protection Rating
NEMA Type 12
Size
8.00x6.00x4.00
Size
8.00x6.00x4.00 in
Steel Panel
A8P6
Thickness
0.14 in
Thickness
51.40mm (2.024")
Type
Window Screw Cover
Type
Fiberglass and Thermoplastic Wall Mounted Industrial Enclosures
Type Number
Type 13
Weight
2.8 lb
Width
152 mm
Width
6 IN
Package Dimensions (L x W x H)
11.2 IN x 9.2 IN x 7.1 IN
Package Dimensions (L x W x H)
28.448 cm x 23.368 cm x 18.034 cm
Package Weight (Imperial)
2.800 L
Package Weight (Metric)
1.270 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the A864CHSCFGW Controller

This guide provides step-by-step instructions for installing and configuring the A864CHSCFGW Controller on a DIN rail.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the A864CHSCFGW controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the grounding

    Connect the grounding wire to the grounding bushing inside the enclosure. Ensure that all metallic portions extending out of the enclosure are properly grounded.

  3. Wire the connections

    Use terminal connectors to wire the power and communication connections to the controller. Follow the wiring diagram provided in the documentation to ensure correct connections.

  4. Power on the controller

    Turn on the power supply to the controller. Use a multimeter to verify that the voltage levels are within the specified range.

  5. Configure the controller

    Access the controller's configuration interface and input the necessary parameters as per your system requirements. Save the settings.

  6. Calibrate the system

    Perform any required calibration procedures as outlined in the user manual to ensure the controller operates correctly.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.