Authorized nVent Distributor
nVent A84XM5EW18FTCG - Heavy-Duty Disconnect Gray Inside Type 12, 84.12x197.75x18.12, Gray, Steel

nVent A84XM5EW18FTCG Heavy-Duty Disconnect Gray Inside Type 12, 84.12x197.75x18.12, Gray, Steel

UPC: 783510257286


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent Heavy-Duty Disconnect Enclosure (SKU: A84XM5EW18FTCG) is engineered for robust protection of electrical disconnect switches and components in demanding industrial environments. Manufactured by nVent, a trusted leader in electrical enclosure solutions, this Type 12 enclosure offers superior durability and reliability. Its substantial dimensions of 84.12 inches in height, 197.75 inches in width, and 18.12 inches in depth provide ample space for a variety of disconnect switch configurations, including options for one to six doors to accommodate diverse application needs. The rugged steel construction, finished in a neutral gray, ensures long-lasting performance against dust, dirt, oil, and water ingress, making it an ideal choice for harsh manufacturing floors, processing plants, and outdoor installations where environmental protection is paramount. This enclosure is designed for simplicity, heavy-duty performance, and cost-effectiveness, making it a practical solution for electrical engineers, facility managers, and system integrators. The Type 12 rating signifies its suitability for indoor use where it must protect against falling dirt and dripping water. The robust build quality inherent in nVent products means this enclosure is built to withstand the rigors of industrial operations, safeguarding critical electrical infrastructure and ensuring operational continuity. Its straightforward design facilitates efficient installation and maintenance, reducing downtime and associated costs. The generous internal volume allows for easy wiring and component access, simplifying the setup process and future modifications. Key features and benefits of the nVent Heavy-Duty Disconnect Enclosure include: * **Robust Steel Construction:** Provides exceptional mechanical strength and impact resistance, ensuring the longevity of the enclosure and its contents. * **Type 12 Rating:** Offers reliable protection against dust, dirt, and dripping water, suitable for most indoor industrial applications. * **Generous Dimensions:** 84.12" H x 197.75" W x 18.12" D provides ample space for various disconnect switch sizes and configurations. * **Configurable Door Options:** Available with one to six doors, allowing for flexible design and accessibility tailored to specific operational requirements. * **Cost-Effective Solution:** Delivers high-value protection without compromising on quality or performance, making it an economical choice for budget-conscious projects. * **nVent Brand Assurance:** Manufactured by nVent, a globally recognized leader in electrical protection and connection solutions, ensuring quality and reliability. Typical applications for this heavy-duty disconnect enclosure span across numerous industries, including automotive manufacturing, food and beverage processing, chemical plants, water and wastewater treatment facilities, and general industrial automation. It is essential for housing and protecting main disconnect switches, motor control centers, and other critical electrical assemblies that require a secure and environmentally resistant housing. The UNSPSC code 39121324 further categorizes this product under electrical enclosures, highlighting its specific function within electrical infrastructure management. When selecting an enclosure, professionals consider factors such as environmental conditions, required protection levels, internal component size, accessibility needs, and overall system integration. The nVent A84XM5EW18FTCG meets these criteria with its durable construction, versatile design, and trusted manufacturer reputation. Its origin in the USA underscores a commitment to quality manufacturing standards.
  • Seams continuously welded and ground smooth
  • Body stiffeners in larger enclosures for extra rigidity
  • Body flange trough excludes liquids and contaminants
  • Heavy-duty lifting eyes anchor into reinforced top
  • Removable centerposts permit easy panel installation
  • Concealed, easy-to-remove hinges
  • Heavy-duty 3-point latching mechanism operated by padlocking handle on all doors
  • Panel supports
  • Data pocket is high-impact thermoplastic
  • Oil-resistant gasket

Specifications

Application
Arc Flash Safety;Controls and Drives;Power Distribution
Application
Controls and Drives; Power Distribution; Arc Flash Safety
Color
Gray
Conductive Large Panel
A84PM78G
Conductive Small Panel
A84PM40G
Depth
18.12
Depth
460
Depth
460 mm
Exterior Color
Gray
Exterior Color Code
ANSI 61
Finish
Powder Coated
Height
2,137 mm
Height
84.12
Height
2,137
Interior Color
Gray
IP Rating
IP55
Large Painted Panel
A84PM78
Large Panel Quantity
2
Large Panel Size
1829 x 1829 mm
Large Panel Size
72.00 x 72.00 in
Material
Mild Steel
Material
Steel
Modification Services
Yes
NEMA Rating
12
NEMA Rating
12 Indoor, dust-resistant
Nema Rating
Type 12
Panel Included
Yes
Protection Rating
NEMA Type 12
Size
84.12x197.75x18.12 inches
Size
84.12x197.75x18.12
Size
84.12x197.75x18.12 in
Small Painted Panel
A84PM40
Small Panel Quantity
1
Small Panel Size
1829 x 857 mm
Small Panel Size
72.00 x 33.75 in
Thickness
11 ga
Thickness
3.04 mm
Thickness
51.40mm (2.024")
Type
Mild Steel Freestanding Industrial Disconnect Enclosures
Type Number
Type 12
Weight
2,742 lb
Width
5,023 mm
Width
197.75
Width
5,023
With or Without Panel
With
Package Dimensions (L x W x H)
208 IN x 36 IN x 93 IN
Package Dimensions (L x W x H)
528.32 cm x 91.44 cm x 236.22 cm
Package Weight (Imperial)
2742.000 L
Package Weight (Metric)
1243.771 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Safely Handle and Install Large Hoffman Enclosures

This guide provides instructions for safely handling and installing large Hoffman enclosures, emphasizing precautions to prevent injury and equipment damage.

Estimated time: 1h

Tools needed:

Forklift, Overhead lifting device (e.g., crane), Slings with load-rated hooks or shackles, ROLL•A•LIFT™ or similar device (for some models)

Supplies needed:

3000 lb.-rated chain or strap (for securing to forklift mast), Rigging equipment (for overhead lifting)

  1. Read Safe Handling Requirements

    Before moving or installing the enclosure, thoroughly read and understand the 'Large Enclosure Safe Handling Requirements' document that accompanied the enclosure. Ensure the route is clear of obstructions and all personnel are at a safe distance.

  2. Prepare for Movement

    Ensure the enclosure is stabilized before removing any strapping. Verify that the lifting equipment (forklift or overhead device) has a sufficient load rating for the enclosure's weight and size. Only trained and authorized personnel should operate the lifting equipment.

  3. Position Forklift Forks

    For forklift handling, spread the forks to the maximum distance or as dictated by the skid width. Enter the skid from the rear (Side A) of the enclosure. Position the enclosure carefully on the forks, keeping the load against the carriage/mast and tilting the load backward towards the mast.

  4. Secure Enclosure to Forklift

    If using a forklift, secure the enclosure to the forklift mast before moving. Insert a 3000 lb.-rated chain or strap through the eye bolts provided on top of the enclosure and fasten it securely to the forklift mast assembly. Ensure sufficient tension to prevent tipping.

  5. Lift and Transport Enclosure

    Lift the enclosure a minimum distance so the skid is just clear of the floor. Start and stop the forklift slowly and gradually, avoiding jerky movements. Drive slowly with the forks carried as low to the ground as possible. Never attempt to move more than one enclosure at a time.

  6. End Loading/Unloading (if applicable)

    For end loading/unloading on trailers, spread forks to match pallet end slot openings and enter from the narrow side (C or D). Secure the enclosure to the forklift mast using chains or straps. Tilt the mast to take weight off the opposite end and slide/push the enclosure as required. Do not use chains or straps to lift the enclosure.

  7. Overhead Lifting (if applicable)

    If using overhead lifting, attach rigging to the eye bolts, ensuring the angle between lifting cables and the vertical does not exceed 45 degrees. Use slings with adequate load-rated hooks or shackles. Ensure the load rating of the lifting device and rigging is sufficient. Do not use ropes or cables through eye bolts.

  8. Final Placement

    Once the enclosure is at its final location, carefully position it. Ensure it is stable and permanently installed according to any specific product instructions not covered in this general handling guide. Refer to the nameplate or datasheet for model-specific details.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.