nVent A84XD4EW24FTCLP - Sequestr External Disconnect Pkg Wht In Type 12, 84.12x158.00x24.12, Gray, Steel
nVent

A84XD4EW24FTCLP

UPC: 783510169541


Documents & Media
Installation Instructions

Contact for Pricing

Overview

Enhance electrical safety and operational efficiency with the nVent Sequestr External Disconnect Enclosure Package (SKU: A84XD4EW24FTCLP). Designed to significantly mitigate arc flash hazards, this robust Type 12 enclosure provides a critical layer of protection by isolating incoming power from the main electrical enclosure. This proactive measure allows maintenance personnel to safely work on interior components without the risk of exposure to live electrical energy. The Sequestr External Disconnect Package is engineered for seamless integration into new installations, arriving as a complete, pre-assembled unit. It features a high-quality disconnect switch and a fuse block or circuit breaker, all housed within the durable gray steel external enclosure. The internal terminal connections are meticulously designed to facilitate the safe and efficient transfer of power to the primary enclosure, ensuring a streamlined and secure electrical distribution system. This product is an essential component for facilities prioritizing safety and compliance with stringent electrical codes and standards. Key benefits and features of the nVent Sequestr External Disconnect Enclosure Package include: * **Arc Flash Mitigation:** Directly addresses arc flash risks by providing a reliable disconnect point, safeguarding personnel. * **Pre-Assembled Convenience:** Shipped as a single unit, simplifying installation and reducing on-site assembly time for new projects. * **Robust Construction:** Manufactured from durable steel with a Type 12 rating, offering superior protection against dust, dirt, and water ingress, suitable for demanding industrial environments. * **Integrated Disconnect and Protection:** Combines a disconnect switch with fuse block or circuit breaker functionality for comprehensive power control and protection. * **Versatile Application:** Ideal for a wide range of industrial applications, including manufacturing plants, processing facilities, data centers, and any environment where electrical equipment requires safe isolation for maintenance. When selecting external disconnect solutions, engineers and electricians prioritize reliability, safety certifications, and ease of installation. nVent, a globally recognized leader in electrical enclosure solutions, consistently delivers products that meet these critical requirements. The Sequestr External Disconnect Package exemplifies nVent's commitment to innovation and safety, providing a dependable solution for managing electrical hazards. Its thoughtful design ensures that power can be reliably isolated, tested, and re-energized, minimizing downtime and maximizing worker safety. The compact dimensions (84.12x158.00x24.12 mm) allow for flexible mounting options, further enhancing its applicability across diverse electrical infrastructure designs. Investing in the nVent Sequestr External Disconnect Package is an investment in a safer, more compliant, and more efficient operational future.
  • Interlocks doors of main control cabinet when disconnect switch is powered ON
  • Mechanical interlock on main control enclosure activated by master door prevents slave door from being opened first
  • Provision for pass-through power into the main enclosure
  • Preferred disconnect cutout
  • Quarter-turn, screwdriver slot latch on Sequestr Enclosure
  • Rugged PowerGlide Handle with three-point latch on main control enclosure
  • Concealed, easy-to-remove hinges
  • Grounding studs on body
  • Bonding provision on door
  • Conductive back panel included in Sequestr External Disconnect Enclosure

Specifications

Application
Power Distribution; Controls and Drives; Arc Flash Safety
Color
Gray
Depth
24.12 in
Depth
613 mm
Exterior Color
Gray
Exterior Color Code
ANSI 61
Finish
Powder Coated
Height
84.12 in
Height
2,137 mm
Interior Color
White
IP Rating
IP55
Large Panel
A84PM78
Material
Steel
Material
Mild Steel
Modification Services
Yes
Nema Rating
Type 12
NEMA Rating
12 Indoor, dust-resistant
Panel Quantity
2
Panel Size
1829 x 1829 mm
Panel Size
72.00 x 72.00 in
Product Family
Sequestr
Protection Rating
NEMA Type 12
Size
84.12x158.00x24.12 in
Size
84.12x158.00x24.12
Thickness
1.52 mm
Thickness
16 ga
Type
Mild Steel Freestanding Industrial Disconnect Enclosures
Type Number
Type 12
Weight
1,989 lb
Width
4,013 mm
Width
158 in
Package Dimensions (L x W x H)
168 IN x 36 IN x 94 IN
Package Dimensions (L x W x H)
426.72 cm x 91.44 cm x 238.76 cm
Package Weight (Imperial)
1989.000 L
Package Weight (Metric)
902.210 kg
Sequestr External Disconnect Pkg Wht In Type 12, 84.12x158.00x18.12, Gray, Steel

A84XD4EW18FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 84.12x158.00x18.12, Gray, Steel
Sequestr External Disconnect Pkg Wht In Type 12, 84.12x197.75x24.12, Gray, Steel

A84XD5EW24FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 84.12x197.75x24.12, Gray, Steel
Sequestr External Disconnect Pkg Wht In Type 12, 84.12x118.75x18.12, Gray, Steel

A84XD3EW18FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 84.12x118.75x18.12, Gray, Steel
Sequestr External Disconnect Pkg Wht In Type 12, 72.12x118.75x18.12, Gray, Steel

A72XD3EW18FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 72.12x118.75x18.12, Gray, Steel
Sequestr External Disconnect Pkg Wht In Type 12, 84.12x236.00x24.12, Gray, Steel

A84XD6EW24FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 84.12x236.00x24.12, Gray, Steel
Sequestr External Disconnect Pkg Wht In Type 12, 84.12x197.75x18.12, Gray, Steel

A84XD5EW18FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 84.12x197.75x18.12, Gray, Steel
Sequestr External Disconnect Pkg Wht In Type 12, 84.12x78.50x24.12, Gray, Steel

A84XD7824FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 84.12x78.50x24.12, Gray, Steel
Sequestr External Disconnect Pkg Wht In Type 12, 84.12x118.75x24.12, Gray, Steel

A84XD3EW24FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 84.12x118.75x24.12, Gray, Steel
Sequestr External Disconnect Pkg Wht In Type 12, 90.12x158.00x24.12, Gray, Steel

A90XD4EW24FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 90.12x158.00x24.12, Gray, Steel
Sequestr External Disconnect Pkg Wht In Type 12, 90.12x118.75x24.12, Gray, Steel

A90XD3EW24FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 90.12x118.75x24.12, Gray, Steel
Sequestr External Disconnect Pkg Wht In Type 12, 90.12x158.00x18.12, Gray, Steel

A90XD4EW18FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 90.12x158.00x18.12, Gray, Steel
Sequestr External Disconnect Pkg Gry In Type 12, 84.12x158.00x24.12, Gray, Steel

A84XD4EW24FTCLPG

Sequestr External Disconnect Pkg Gry In Type 12, 84.12x158.00x24.12, Gray, Steel

How to Install the WS74XM7524SS Enclosure

This guide provides step-by-step instructions for safely installing the WS74XM7524SS enclosure, ensuring proper handling and setup.

Estimated time: 1h

Tools needed:

Forklift, Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, 3000 lb-rated chain or strap

  1. Prepare the installation area

    Clear the installation route of all obstructions and ensure that workers are at a safe distance, more than the overall height of the enclosure.

  2. Secure the enclosure for transport

    Using a forklift, insert a 3000 lb-rated chain or strap through the eye bolts on top of the enclosure and securely fasten it to the forklift mast. Ensure sufficient tension to prevent tipping.

  3. Lift and position the enclosure

    Carefully lift the enclosure using the forklift, ensuring it is clear of the ground. Position the enclosure at the desired installation location.

  4. Mount the enclosure

    Secure the enclosure to the mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  5. Connect electrical components

    Use wire strippers to prepare the wires and connect them to the terminal connectors as per the wiring diagram provided. Verify connections with a multimeter.

  6. Calibrate the enclosure

    Follow the manufacturer's instructions to perform any necessary calibration of the enclosure's components to ensure proper functionality.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.