nVent A84XD4024FTCLP - Sequestr External Disconnect Pkg Wht In Type 12, 84.12x40.25x24.12, Gray, Steel
nVent

A84XD4024FTCLP

UPC: 783510169534


Documents & Media
Installation Instructions

Contact for Pricing

Overview

Enhance worksite safety and operational efficiency with the nVent Sequestr External Disconnect Enclosure Package (SKU: A84XD4024FTCLP). Designed to significantly mitigate arc flash hazards, this robust enclosure isolates incoming power from interior components of the main electrical panel. This proactive measure allows maintenance personnel to safely work on internal equipment without the risk of exposure to live electrical energy, a critical consideration in today's demanding industrial environments. The Sequestr External Disconnect Package is engineered for straightforward installation, arriving as a single, pre-assembled unit. This integrated design simplifies the setup process for new installations, ensuring that the disconnect switch and fuse block or circuit breaker are correctly mounted within the external enclosure. Terminal connections are provided to efficiently route power to the main enclosure, streamlining the overall electrical system integration. The enclosure itself is constructed from durable steel, finished in a neutral gray, and rated for Type 12 protection, making it suitable for a wide range of industrial applications where protection against dust, falling dirt, and dripping water is essential. Key benefits of implementing the nVent Sequestr External Disconnect Package include: * **Arc Flash Hazard Mitigation:** Provides a critical safety barrier by isolating power sources, drastically reducing the risk of arc flash incidents. * **Improved Maintenance Safety:** Enables safe access to interior electrical components for inspection, repair, and routine maintenance. * **Streamlined Installation:** Shipped as a complete, one-unit package, simplifying and accelerating new installations. * **Robust Construction:** Built with durable steel and a Type 12 rating for reliable performance in harsh industrial settings. * **Versatile Application:** Ideal for use in manufacturing plants, processing facilities, utility substations, and any environment where electrical equipment requires safe isolation for maintenance. This package is a testament to nVent's commitment to providing advanced safety solutions for electrical infrastructure. Professionals rely on nVent for their innovative designs and high-quality manufacturing, ensuring that critical safety equipment meets stringent industry standards. The dimensions of this specific model are 84.12 inches in height, 40.25 inches in width, and 24.12 inches in depth, offering ample space for internal components while maintaining a manageable footprint. By investing in the Sequestr External Disconnect Package, organizations demonstrate a strong commitment to worker safety and operational continuity, minimizing downtime and protecting valuable personnel.
  • Interlocks doors of main control cabinet when disconnect switch is powered ON
  • Mechanical interlock on main control enclosure activated by master door prevents slave door from being opened first
  • Provision for pass-through power into the main enclosure
  • Preferred disconnect cutout
  • Quarter-turn, screwdriver slot latch on Sequestr Enclosure
  • Rugged PowerGlide Handle with three-point latch on main control enclosure
  • Concealed, easy-to-remove hinges
  • Grounding studs on body
  • Bonding provision on door
  • Conductive back panel included in Sequestr External Disconnect Enclosure

Specifications

Application
Controls and Drives; Arc Flash Safety; Power Distribution
Color
Gray
Depth
24.12 in
Depth
613 mm
Exterior Color
Gray
Exterior Color Code
ANSI 61
Finish
Powder Coated
Height
84.12 in
Height
2,137 mm
Interior Color
White
IP Rating
IP55
Material
Steel
Material
Mild Steel
Modification Services
Yes
Nema Rating
Type 12
NEMA Rating
12 Indoor, dust-resistant
Panel
A84PM40
Panel Size
72.00 x 33.75 in
Panel Size
1829 x 857 mm
Product Family
Sequestr
Protection Rating
NEMA Type 12
Series
Sequestr
Size
84.12x40.25x24.12 in
Thickness
1.52 mm
Thickness
16 ga
Type
Mild Steel Freestanding Industrial Disconnect Enclosures
Type Number
Type 12
Weight
70 lb
Width
1,022 mm
Width
40.25 in
Package Dimensions (L x W x H)
1 IN x 1 IN x 1 IN
Package Dimensions (L x W x H)
2.54 cm x 2.54 cm x 2.54 cm
Package Weight (Imperial)
70.000 L
Package Weight (Metric)
31.752 kg
Sequestr External Disconnect Pkg Wht In Type 12, 72.12x34.25x18.12, Gray, Steel

A72XD3418FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 72.12x34.25x18.12, Gray, Steel
Sequestr External Disconnect Pkg Wht In Type 12, 84.12x40.25x18.12, Gray, Steel

A84XD4018FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 84.12x40.25x18.12, Gray, Steel
Sequestr External Disconnect Pkg Wht In Type 12, 72.12x40.25x18.12, Gray, Steel

A72XD4018FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 72.12x40.25x18.12, Gray, Steel
Sequestr External Disconnect Pkg Wht In Type 12, 72.12x28.25x18.12, Gray, Steel

A72XD2818FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 72.12x28.25x18.12, Gray, Steel
Sequestr External Disconnect Pkg Wht In Type 12, 72.12x54.50x18.12, Gray, Steel

A72XD5418FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 72.12x54.50x18.12, Gray, Steel
Sequestr External Disconnect Pkg Wht In Type 12, 84.12x118.75x18.12, Gray, Steel

A84XD3EW18FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 84.12x118.75x18.12, Gray, Steel
Sequestr External Disconnect Pkg Wht In Type 12, 72.12x118.75x18.12, Gray, Steel

A72XD3EW18FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 72.12x118.75x18.12, Gray, Steel
Sequestr External Disconnect Pkg Wht In Type 12, 84.12x78.50x24.12, Gray, Steel

A84XD7824FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 84.12x78.50x24.12, Gray, Steel
Sequestr External Disconnect Pkg Wht In Type 12, 84.12x197.75x24.12, Gray, Steel

A84XD5EW24FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 84.12x197.75x24.12, Gray, Steel
Sequestr External Disconnect Pkg Wht In Type 12, 84.12x236.00x24.12, Gray, Steel

A84XD6EW24FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 84.12x236.00x24.12, Gray, Steel
Sequestr External Disconnect Pkg Wht In Type 12, 84.12x158.00x24.12, Gray, Steel

A84XD4EW24FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 84.12x158.00x24.12, Gray, Steel
Sequestr External Disconnect Pkg Wht In Type 12, 72.12x78.50x24.12, Gray, Steel

A72XD7824FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 72.12x78.50x24.12, Gray, Steel

How to Install the Sequestr External Disconnect Enclosure

This guide provides step-by-step instructions for installing the Sequestr external disconnect enclosure to a control enclosure, ensuring proper mounting, wiring, and initial setup.

Estimated time: 1h

Tools needed:

Screwdriver, Drill, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, Hoffman hole seal, Hoffman blank adapter plate

  1. Power Down the System

    Turn off the local disconnect and feeder disconnect. Put on appropriate Personal Protective Equipment (PPE) and open the control enclosure. Test for power on the incoming side of the disconnect using a voltmeter.

  2. Prepare the Control Enclosure

    Remove the existing disconnect from the control enclosure and seal the existing hole with a Hoffman hole seal. Cover all components in the control enclosure to protect them.

  3. Mount the Sequestr Enclosure

    Remove the subpanel from the Sequestr enclosure. Drill a hole for the power line entrance, then hang the Sequestr enclosure on the control enclosure using M6x16mm bolts. Secure it with M6x16mm washer head cap screws from inside the control enclosure.

  4. Install Circuit Breaker/Disconnect Switch

    Drill mounting holes in the panel for the disconnect switch or circuit breaker. Install the device according to the manufacturer's instructions and secure the panel back into the Sequestr enclosure.

  5. Connect Wiring

    Install conduit and wires to the incoming side of the circuit breaker/disconnect switch in the Sequestr enclosure. Ensure all connections are secure and properly insulated.

  6. Power Up the System

    Remove any protective coverings, verify the operator handle is in the 'OFF' position, and securely close both the Sequestr and control enclosure doors. Turn on the feeder disconnect switch and then flip the operator handle to the 'ON' position.

  7. Verify Operation

    Check that the system operates correctly with the new electrical connection. If there are any issues, do not attempt to operate the equipment and report the problem.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.