Enhance workplace safety and operational efficiency with the nVent Sequestr External Disconnect Enclosure Package (SKU: A72XD7824FTCLP). Designed to significantly mitigate arc flash hazards during maintenance or servicing of interior enclosure components, this robust package effectively isolates incoming power from the main electrical enclosure. This proactive safety measure is crucial in environments where personnel must access internal equipment, ensuring that power can be safely disconnected externally without compromising the integrity of the main enclosure's protection. The Sequestr External Disconnect Package is engineered for seamless integration into new electrical installations. It arrives as a single, pre-assembled unit, simplifying the installation process and reducing on-site labor. The integrated disconnect switch and fuse block or circuit breaker are housed within the external enclosure, providing a centralized point for power isolation. Terminal connections are thoughtfully designed to efficiently route power to the main enclosure, maintaining a clean and organized electrical system. Constructed from durable steel with a protective gray finish, this Type 12 enclosure is built to withstand demanding industrial conditions. Its substantial dimensions (72.12" H x 78.50" W x 24.12" D) offer ample space for robust disconnect mechanisms and wiring, ensuring reliable performance and longevity. The external disconnect functionality is a critical component for compliance with stringent electrical safety standards and best practices in industries such as manufacturing, utilities, and data centers. Key benefits and features include: * **Arc Flash Hazard Mitigation:** Isolates incoming power, drastically reducing arc flash risks for personnel working inside the main enclosure. * **Simplified Installation:** Shipped as a complete, pre-assembled package for new installations, saving time and resources. * **Integrated Disconnect and Protection:** Combines a disconnect switch with a fuse block or circuit breaker for comprehensive power control. * **Durable Construction:** Robust steel enclosure with a Type 12 rating ensures protection against dust and water ingress in industrial environments. * **Enhanced Safety Compliance:** Facilitates adherence to electrical safety regulations and promotes a safer working environment. By implementing the nVent Sequestr External Disconnect Enclosure Package, facility managers and electrical engineers can significantly improve safety protocols, minimize downtime associated with arc flash incidents, and ensure the reliable operation of critical electrical systems. nVent is a globally recognized leader in electrical solutions, known for its commitment to innovation, quality, and safety, making this product a trusted choice for demanding industrial applications.
  • Interlocks doors of main control cabinet when disconnect switch is powered ON
  • Mechanical interlock on main control enclosure activated by master door prevents slave door from being opened first
  • Provision for pass-through power into the main enclosure
  • Preferred disconnect cutout
  • Quarter-turn, screwdriver slot latch on Sequestr Enclosure
  • Rugged PowerGlide Handle with three-point latch on main control enclosure
  • Concealed, easy-to-remove hinges
  • Grounding studs on body
  • Bonding provision on door
  • Conductive back panel included in Sequestr External Disconnect Enclosure

Specifications

Application
Arc Flash Safety; Controls and Drives; Power Distribution
Color
Gray
Depth
613 mm
Depth
24.12 in
Exterior Color
Gray
Exterior Color Code
ANSI 61
Finish
Powder Coated
Height
72.12 in
Height
1,832 mm
Interior Color
White
IP Rating
IP55
Material
Steel
Material
Mild Steel
Modification Services
Yes
Nema Rating
Type 12
NEMA Rating
12 Indoor, dust-resistant
Panel
A72PM78
Panel Size
1524 x 1829 mm
Panel Size
60.00 x 72.00 in
Product Family
Sequestr
Protection Rating
NEMA Type 12
Series
Sequestr
Size
72.12x78.50x24.12 in
Size
72.12x78.50x24.12
Stiffener Locations
610 mm
Stiffener Locations
24 in
Thickness
16 ga
Thickness
1.52 mm
Type
Mild Steel Freestanding Industrial Disconnect Enclosures
Type Number
Type 12
Weight
965 lb
Width
78.5 in
Width
1,994 mm
Package Dimensions (L x W x H)
84 IN x 34 IN x 82 IN
Package Dimensions (L x W x H)
213.36 cm x 86.36 cm x 208.28 cm
Package Weight (Imperial)
965.000 L
Package Weight (Metric)
437.724 kg
Sequestr External Disconnect Pkg Wht In Type 12, 72.12x78.50x18.12, Gray, Steel

A72XD7818FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 72.12x78.50x18.12, Gray, Steel

How to Install the Sequestr External Disconnect Enclosure

This guide provides step-by-step instructions for installing the Sequestr external disconnect enclosure to a control enclosure, ensuring proper mounting, wiring, and initial setup.

Estimated time: 1h

Tools needed:

Screwdriver, Drill, Multimeter, Wire strippers

Supplies needed:

Mounting screws, Terminal connectors, Hoffman hole seal, Hoffman blank adapter plate

  1. Power Down the System

    Turn off the local disconnect in the control enclosure and the feeder disconnect. Wear appropriate Personal Protective Equipment (PPE) and test for power using a voltmeter.

  2. Prepare the Control Enclosure

    Remove the existing disconnect from the control enclosure and seal the hole with a Hoffman hole seal. Protect all components inside the enclosure.

  3. Mount the Sequestr Enclosure

    Remove the subpanel from the Sequestr enclosure. Hang the Sequestr enclosure on the control enclosure using M6x16mm bolts and secure it with washer head cap screws from inside the control enclosure.

  4. Install Circuit Breaker/Disconnect Switch

    Drill mounting holes for the circuit breaker or disconnect switch on the panel. Install the device according to the manufacturer's instructions and secure the panel back into the Sequestr enclosure.

  5. Connect Wiring

    Install conduit and connect wires from the circuit breaker/disconnect switch to the incoming power side of the control enclosure. Ensure all connections are secure.

  6. Power Up the System

    Remove any protective coverings, ensure the operator handle is in the 'OFF' position, close and latch both the Sequestr and control enclosure doors, and turn on the feeder disconnect switch.

  7. Verify Operation

    Flip the operator handle on the Sequestr enclosure to the 'ON' position and verify that the system operates correctly with the new electrical connection.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.