The nVent **Heavy-Duty Disconnect Gray Inside Type 12 Enclosure (SKU: A72XM7824FTCG)** is a robust, cost-effective solution designed for demanding industrial environments where protection and reliability are critical. Engineered by nVent, a global leader in electrical and thermal management solutions, this enclosure provides a secure housing for disconnect switches, circuit breakers, and other control components, ensuring safe operation in harsh conditions. With its **Type 12 rating**, it offers superior protection against dust, dirt, and non-corrosive liquids, making it ideal for manufacturing plants, warehouses, and outdoor installations where exposure to contaminants is a concern. This **heavy-duty steel enclosure** features a **gray finish** and is available with **one to six doors**, allowing for flexible configuration to accommodate varying system requirements. The **72.12 x 78.50 x 24.12 mm** dimensions provide ample internal space for component mounting, while the **steel construction** ensures durability and long-term performance. The **two-door design** enhances accessibility, enabling easier maintenance and troubleshooting without compromising protection. **Key Applications & Industries:** This disconnect enclosure is widely used in industries such as **automotive manufacturing, food processing, chemical plants, and water treatment facilities**, where reliable electrical isolation is essential. It is particularly suited for applications requiring **NEMA Type 12 compliance**, including: - **Motor control centers** - **Pump and fan systems** - **HVAC control panels** - **Industrial machinery enclosures** - **Outdoor electrical distribution** **Why Choose nVent?** nVent is a trusted manufacturer with decades of experience in providing high-performance electrical enclosures and thermal management solutions. Their products are engineered to meet stringent industry standards, ensuring **safety, durability, and compliance** with global regulations. The **Heavy-Duty Disconnect Gray Inside Type 12 Enclosure** exemplifies nVent’s commitment to quality, offering a **cost-effective, low-maintenance solution** that reduces downtime and enhances operational efficiency. **Installation & Compliance Considerations:** When selecting an enclosure, professionals prioritize **NEMA/Type ratings, material durability, and ease of installation**. This nVent enclosure meets **UL 508A and UL 698A standards**, ensuring it can withstand extreme temperatures, vibrations, and mechanical stress. The **pre-drilled mounting holes** simplify installation, while the **hinged door design** allows for quick access to internal components. For optimal performance, ensure proper **ventilation and grounding** during installation to maintain long-term reliability. **Benefits of the nVent A72XM7824FTCG Enclosure:** - **Superior Protection:** Type 12 rating guards against dust, dirt, and non-corrosive liquids. - **Versatile Configuration:** Available with **1-6 doors** to match application needs. - **Durable Construction:** Heavy-duty steel ensures long-term durability in industrial settings. - **Cost-Effective Solution:** Reduces maintenance costs while providing reliable performance. - **Trusted Brand:** nVent’s reputation for quality ensures compliance and peace of mind. Whether you’re upgrading an existing system or designing a new installation, the **nVent Heavy-Duty Disconnect Gray Inside Type 12 Enclosure** delivers the **performance, protection, and flexibility** required for modern industrial applications. Trust nVent to provide a solution that meets the demands of your operation while adhering to the highest safety and compliance standards.
  • Seams continuously welded and ground smooth
  • Body stiffeners in larger enclosures for extra rigidity
  • Body flange trough excludes liquids and contaminants
  • Heavy-duty lifting eyes anchor into reinforced top
  • Removable centerposts permit easy panel installation
  • Concealed, easy-to-remove hinges
  • Heavy-duty 3-point latching mechanism operated by padlocking handle on all doors
  • Panel supports
  • Data pocket is high-impact thermoplastic
  • Oil-resistant gasket

Specifications

Application
Arc Flash Safety;Controls and Drives;Power Distribution
Application
Arc Flash Safety; Power Distribution; Controls and Drives
Color
Gray
Conductive Panel
A72PM78G
Depth
613 mm
Depth
24.12
Depth
613
Exterior Color
Gray
Exterior Color Code
ANSI 61
Finish
Powder Coated
Height
1,832 mm
Height
72.12
Height
1,832
Interior Color
Gray
IP Rating
IP55
Material
Mild Steel
Material
Steel
Modification Services
Yes
NEMA Rating
12 Indoor, dust-resistant
NEMA Rating
12
Nema Rating
Type 12
Painted Panel
A72PM78
Panel Included
Yes
Panel Size
60.00 x 72.00 in
Panel Size
1524 x 1829 mm
Protection Rating
NEMA Type 12
Size
72.12x78.50x24.12
Size
72.12x78.50x24.12 mm
Size
72.12x78.50x24.12 in
Stiffener Locations
610 mm
Stiffener Locations
24 in
Thickness
11 ga
Thickness
3.04 mm
Thickness
51.40mm (2.024")
Type
Mild Steel Freestanding Industrial Disconnect Enclosures
Type Number
Type 12
Weight
1,001 lb
Width
1,994 mm
Width
78.5
Width
1,994
With or Without Panel
With
Package Dimensions (L x W x H)
84 IN x 34 IN x 82 IN
Package Dimensions (L x W x H)
213.36 cm x 86.36 cm x 208.28 cm
Package Weight (Imperial)
1001.000 L
Package Weight (Metric)
454.054 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the WS74XM7524SS Enclosure

This guide provides step-by-step instructions for safely installing the WS74XM7524SS enclosure, ensuring proper handling and setup.

Estimated time: 1h

Tools needed:

Forklift, Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, 3000 lb-rated chain or strap

  1. Prepare the installation area

    Clear the installation route of all obstructions and ensure that workers are at a safe distance, more than the overall height of the enclosure.

  2. Secure the enclosure for transport

    Using a forklift, insert a 3000 lb-rated chain or strap through the eye bolts on top of the enclosure and securely fasten it to the forklift mast. Ensure sufficient tension to prevent tipping.

  3. Lift and position the enclosure

    Carefully lift the enclosure using the forklift, ensuring it is clear of the ground. Position the enclosure at the desired installation location.

  4. Mount the enclosure

    Secure the enclosure to the mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  5. Connect electrical components

    Use wire strippers to prepare the wires and connect them to the terminal connectors as per the wiring diagram provided. Verify connections with a multimeter.

  6. Calibrate the enclosure

    Follow the manufacturer's instructions to perform any necessary calibration of the enclosure's components to ensure proper functionality.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.